Best C520-T Instruction Manual Download Page 3

5

2

B.Parameter and Dimension

 F.Optional Control Type and Electrical Parameters

Working
Voltage

*2

Two core lines

*3

Three core lines

 *4

 

Three core lines

*5

Five core lines

*6

Two core lines

*7

Two core lines

DC5V

DC12V

AC/DC12V

AC/DC24V

AC/DC5V

 AC/DC

95-265V

≤80mA

15±5mA

≤60mA

15±5mA

≤80mA

15±5mA

≤80mA

15±5mA

Maximum 
Power

---

≤900mA

15±5mA

≤900mA

80±10mA

3W

≤60mA

15±5mA

≤60mA

15±5mA

≤60mA

15±5mA

≤60mA

15±5mA

≤600mA

15±5mA

 ≤600mA

55±10mA

3W

4W

4W

5W

5W

---

---

---

---

≤50mA

15±5mA

≤50mA

15±5mA

≤70mA

15±5mA

≤600mA

15±5mA

≤600mA

55±10mA

≤40mA

15±5mA

≤40mA

15±5mA

≤60mA

10±5mA

≤400mA

15±5mA

≤400mA

25±5mA

≤10mA

<5mA

≤10mA

<5mA

≤10mA

<5mA

≤40mA

<5mA

---

≤10mA

<5mA

≤10mA

<5mA

≤10mA

<5mA

≤40mA

<5mA

---

Control

  

Type

A.Feature

Unit:mm

Note:1.The working life is tested under 1.0MPa/normally Temp parameters,different paraments 

              means different working life

          2.C520

-

20

32 can be customized internal/external thread

          3.The action time affected by the valve body,so 

qualified

 tolerance ±2s is 

G.Hand manual function instruction

1.Manual function must be used when power-off
2.Pull up the manual button,then rotary the hand wheel to the valve position you need
3.The red line of pointer in window is parallel to tube line means open;The red line of 
    pointer in window is perpendicular to tube line means closed
4.Must reset the manual button after finish useing,to prove that the electric function can 
    be used normally

Note:1."---
                       2.

currentof controller is  

          3.In above form,upper line is rated working current,lower line is Static rated current.The above 
              current only as a selection reference, the specific current value to the actual prevail
         4 . T h e m a x i m u m c o n t r o l p o w e r o f *6/*7 is 5W

" in above form means that this control type is not applicable for this working voltage

Advice the output 

2-3 times bigger than the current in above form

Order
Model

C

o

n

n

e

c

ti

o

T

h

re

a

d G

Orifice

 mm

Power

  

W

Liquid/Gas

Min
Pressure

bar

Applic-
able
Medium
Temp

Protec-
tion
Grade

 L×W×H
 (A×B×H)

Dimension

C520-8

C520-10

C520-15

3/8"

  1/2" 15

10

8

1/4"

0.26     

           

 

   

 

 

 0

43×67×90

50×67×93

57×67×100

 Ⅱ:
-40
  
 100

~

I P
6 7

Max
Pressure
bar

     10

C520-20

  3/4" 20

70×67×108

0. 3   1    

           

 

   

 

 

0.3   7        

           

 

   

 

 

0.5   2     

           

 

   

 

 

C520-25

C520-32

   1"

  1

1/4"

20

20

Torque

 

N

·

m

Life

 times

W

.

T

.

 

kg

 N

or

m

all

y 7
0,0

00 t

im

es

 

  3

  

  5

~

76×67×109

80×67×112

0.5   8     

           

 

   

 

 

0.7   0     

           

 

   

 

 

2

 Ⅱ:
-40
  
 120

~

 Ⅲ:
-40
  
 150

~

01.Eco,small displacement,special product for Smart water-saving system

02.

,to prevent the actuator from leaking

03.Suitable environment Temp:-20

45

04.

Standard),2s(Custom)

05.

06.Nominal Pressure:1.0MPa

07.

08.

09

10.Body material:Brass coated with Nickel(code:T),SS304(code:B),SS316(code:L)

11.Seal material:PTFE(code:P),VITON(code:V),food-grade NBR,food-grade VITON

12.

No limit for flow direction of medium, mounted at any angle, but 

90° actuation time:5s(

Valve position visible, can with signal output,can with manual device,but just can chose 

      one of them

Leakage: Zero 

Flow rate: After fully open, flow capacity equals the same size pipe

. Equipped with position limit switch, fully open or fully closed, power off immediately, 

      energy-saving, safety guaranteed,long life span

Voltage: AC220/AC110/AC24/AC12V 50/60Hz, tolerance ±10%, DC24 ±5%, 

     customization accepted

the actuator is forbidden 

      to face down