SETTING UP THE BEST DATA 56SPX MODEM
The order of these steps is critical
, particularly when turning
power on to the modem and reader or SK-ACP.
1. Remove power to the 28SA-Plus or SK-ACP
2. Connect cable from reader to modem
3. Turn power to the modem on
4. Turn on power to the 28SA-Plus or SK-ACP
The modem is now set to auto answer and dumb mode. You
can now connect to reader from the PC location. Verify that the
TR, CD and AA lights are lighted (on) on the modem display.
NOTE:
The default baud rate is 9600 baud. A 38,400 baud rate
is recommended. You can change the baud rate of a 28SA-Plus
using the PD-26 program deck, and the SK-ACP using SK-
NET
TM
or a terminal program.
REMOTE SITE MODEM CONFIGURATION with 28SA-PLUS
REMOTE SITE MODEM CONFIGURATION WITH SK-ACP
TELCO
LINE
SK-MDM
MODEM
¿
SK-ACP
SK-ACP
SK-ACP
Up to 100
SK-ACPs
RS-232
GATEWAY
¿
RS-485 NETWORK
MODULE SK-NM485
TELCO
LINE
SK-MDM
28SA-Plus
MODEM
Up to 128
28SA Plus Units
RS-232 GATE-
WAY
¿
¿
¿
RS-485
NETWORK
¿
¿
¿