background image

"Histo1y data" is for data collected by gas detector and data have been stored on computer. 

"Select device" to see available histo1y data of a ce1tain gas detector. 

"DEL" is to delete just model number of gas detectors which have been registered on this computer, this 

function is for  a better management of more than  one  gas  detector you  use.  When  you  register it  the 

second time, you'll find all histo1y data. 

User can also check data in a ce1tain day by setting sta1t-stop time, strut and stop time need to be in same 

d

a

y; if not, you '11 get min, ave, max values for each gas and each day. 

Place mouse pointer on any point of collected data cmve, you'll get exact time and concentration of this 

data. 

Press left mouse and drag from left to light to spread all detailed d

a

ta points, and drag from 1ight to left to 

pull 

back, or click cross point of x and y axises to pull back. 

On  1ight  side  of  the  cha1t,  you'll  find  3  gas  analyzing  circle  diagrams  with  "Avg" 

"Min""Max", tick circles below to see analysis for each gas. 

Click  "Disconnect"  to  disconnect  this  gas  detector  with  softwai·e,  stan1s  will  become: 

Disconnected 

Show data 

Reol-lrn•�• 

..  Hoslo1y dolo 

H2S 

12 

02 

Cl 

co 

Cl 

Cll4 

02 

X:2014-7-4  11:05:06 

Y: 14. 2  ?!vol 

2014-07•04 

-

to 

-

Export 

Search 

------------------------

Click "Expo1t" to expo1t data in excel fo1mat. 

2014•07 •04 

CO:ppm 

Search 

Summary of Contents for BST-MG08

Page 1: ...t brand B Low Alarm L C High Alarm HJ D STEL Alarm SJ E TWA Alarm T F Preset Calibration Value G Product number and next calibrate date 30 seconds countdown H Auto Zero option BESANTEK LLJLIU Al i Rll SJ T ll ii Ml 0 00 02 20 9 l l OL 0 co Pl M H2S PPM 0 2Q16 09 22 II i II Alarm 9 Time Calibr ation Setting LOGO Main Interface Function interface 3 In auto zero option after seeing Adjust Zero long p...

Page 2: ...h Alarm Set STEL Alarm and Set TWA Alarm Short press OK button to enter each setting Alarm L Alarm H STEL S TWA T short press A or T to set the value long press OK button to complete the operation with display set OK Short press 0 to exit 9 In time setting interface short press OK button to select Year Month Day Hour Min then press A or T to adjust the value Long press OK button to complete this o...

Page 3: ...e calibrated in fresh air 11 In setting interface short press A or f f to select among CH4 LEL PPM MG m3 Allow Calibration 11 means item is selected Long press OK button to select and confirm Short press 9 11 to exit Important User can t enter calibration interface without choosing Allow Calibration 4 Technical Parameter Technical Parameter Specification Measured gas Methane CH4 Oxygen O2 Carbon M...

Page 4: ...ifetime CH4 1 year CO H2S O2 2 years Alarms Audible buzzer with 85dB lm audible Visible flashing red LED 20m visible Vibration Charging time 4 Shours Continuous operating 13 hours hours Battery model PL123450 3 7V 1500mA Protect Grade IP66 Working temperature 2s c so c Size mm 130 70 37 Data logging for Continuously data logging MG08 only 100000 records with 1 10 minutes interval Enclosure PC ABS ...

Page 5: ...cators user can know power left easily Technical parameter Samplin2 Air Flow 1600ml min Samplin2 Distance 30m Workin2 Temperature 20 500 Workin2 Humidity 90 RH Power Source 3 7V rechargeable lithium batte1y Output SW Input DCSV IA CharITTn2 Time 8h Weight 200g How to turn ON and OFF this pump Long press power switch to activate this pump and long press power switch again to shut it off ...

Page 6: ...work 2 Gascheck Driver and Software Installation 2 1 Open CD Rom Driver on your computer and put the offered CD into it 2 2 Read the CD and find Gas Check Driver programme then choose light file according to your computer OS 2 3 Double click Prelnstaller exe or CP210xVCPinstaller exe and click Install then you ll see window prompt with Installation Successfully 2 4 To confilm this diiver has been ...

Page 7: ...y device time needed is 1 6 minutes device will show Loading during this period 2 Check analyze these data on Data show section Histo1y data 3 This softwai e can get and store data from several gas detectors when data acquisition finished for one device click Disconnect and connect with another one 4 Click Clear data to delete all data collected by gas detector 5 When collecting data by device use...

Page 8: ...values for each gas and each day Place mouse pointer on any point of collected data cmve you ll get exact time and concentration of this data Press left mouse and drag from left to light to spread all detailed da ta points and drag from 1ight to left to pull back or click cross point ofx and y axises to pull back On 1ight side of the cha1t you ll find 3 gas analyzing circle diagrams with Avg Min M...

Reviews: