Page 1: ...BST ELC06 DIGITAL RCD TESTER Version A 240VAC Version B 230VAC Version C 220VAC Version D 110VAC INSTRUCTION MANUAL Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...

Page 2: ... 2 Specifications 3 Features 4 Connections 5 Instrument layout 6 RCD Test 7 Preparation for measurement 8 Battery replacement 9 Fuse replacement 10 Servicing and calibration 11 Cleaning and storage Page 1 2 3 4 4 5 6 7 8 8 8 9 9 ...

Page 3: ...ter except for battery replacement See Battery replacement section 1 3 Always inspect you Digital RCD tester and test leads before using for any sign of abnormality or damage If any abnormal conditions exist broken test leads cracked case display faulty etc do not attempt to take any measurement or use the tester Return your Digital RCD tester to your nearest Distributor for Service 1 4 Never repl...

Page 4: ...ion Category Ill 300V 3 Pollution Degree 2 4 Altitude up to 2000Meters 5 Relative Humidity 80 Maximum 6 Ambient Temperature 0 40 C 1 8 Observe the International Electric symbols listed below rr il Meter is protected throughout by double l J insulation or reinforced insulation A Caution Refer to this manual before using t D the meter Warning Risk of electric shock 2 Test Equipment Depot 800 517 843...

Page 5: ...rip Indicator Yes LCD Operating Voltage L E 50Hz or 60Hz Version A Version B Version C Version D 240VAC 230VAC 220VAC 110VAC Voltmeter L E 10Vac 280Vac 50Hz or 60Hz Timer Resolution 1ms Max Time 2 999S Timer Accuracy 2ms Current Accuracy 5 1mA Voltmeter Resolution 1VAC Voltmeter Accuracy 2 1VAC Operating Temperature 0 C 40 C Storage Temperature 10 C 50 C Power source 1 5V AA 6 Alkaline battery Mea...

Page 6: ...ge protection Fuse protection Zero crossing circuitry permit testing at 0 or 180 Auto power off in 3 minutes Backlight function Wiring polarity indicator Measure voltage between Line and Earth before testing Frequency measurement indication 4 Connections Neutral Probe Connection Line Hot Probe Connection e I I I FUSE MAX AC 280V L N E Fuse compartment lid apply only Operating Voltage 10 SOHz or 60...

Page 7: ...ument Layout 10 1 1 LCD 2 0 180 Phase angle select button 3 ESC button 4 TEST button 5 Function rotary switch 6 3 Backlight button 5 7 6 7 ON OFF button 8 Fuse 9 L LINE terminal 10 N NEUTRAL terminal 11 E EARTH terminal ...

Page 8: ...v i m Yobge 0 Batton Hz J U 2 When connect the instrument to a 240V system with an RCD the LCD will come to the following screen 3 Press the 0 180 button to select the phase angle 0 or 180 Then press the TEST button to do the test the LCD will come to the following screen e2 0 T ill ISs L E2 Jv r D1J26s Hold old 60Hz B119DYv _ 60Hz 811 90 Iv 00 6 180 ...

Page 9: ...instrument stops working The user needs to wait until the instrument cool down 0 E YOv 60Hz s 999 5 If the battery voltage is too low the LCD will come to the following screen the symbol will show on the LCD Plase replace with new batteries L E Uv 7 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...

Page 10: ...gital RCD Tester s batteries are situated under the tester Disconnect the Test leads from the Instrument remove the battery cover and the batteries Replace with six 1 5V AA alkaline batteries taking care to observe correct polarity Replace the Battery cover 9 Fuse Replacement Open the fuse compartment lid Remove the bad fuse and replace with the new one Replace the fuse compartment lid Fuse 1A 500...

Page 11: ...al RCD tester has been factory Calibrated However it is of good practice to have your Instrument CERTIFIED by a National Calibration Facility and CHECKED every year by an Professional workshop 11 Cleaning and Storage Periodically wipe the case with a damp cloth and Detergent do not use abrasives or solvents If meter is not to be used for periods longer than 60 days remove the batteries and store t...