LOGGER SPECIFICATION

P2

Model no.

BST-DL71

Temp. range

-40~85℃ (-40~185℉)

Accuracy

±0.5℃/1.2℉(-20~50℃), others±1.2℃

RH% range

0%RH~99.9%RH

Accuracy

±3%RH (at 25℃, 10~90%RH), others±5%RH)

Dew Point. Wet Bulb

YES

Memory capacity

32,000 points

Power

3.6V battery 1/2AA

Logger

135 x 28.5 mm

2.   Select the destination folder you are go to save by click Browse button

3.   Once you finish selecting ,press Next

”.

4.   Select “I accept the License Agreemen:(s)” and press NEXT button.

2.

The set up status

3.    Click”NEXT” to continue.
4.

After complete the installation , press Finished

A. Install logger driver for Windows OS ( WinXP, Vista,Win7.Win8,
Win8.1)

The PL2303_Prolific_DriverInstaller_v110.exedriver is for Windows operation
system,follow the installation steps hereunder:
1. Put the CD into CD driver in Step1, click
PL2303_Prolific_DriverInstaller_v110.exe for installation the driver.

B Install the logger software for Windows OS (List above)

.

Please follow the following steps to install the software
1.    Put CD into CD driver ,in Step 2. click

Setup.exe

to install

5.   Click NEXT button when you see the following.
6.   Press FINISH button to complete the installation.
7.   Restart the Windows XP system

LOGGER SETUP

Summary of Contents for BST-DL71

Page 1: ...OPERATION MANUAL USB DATALOGGER Temp RH DP WB BST DL71 ...

Page 2: ... application is applicable and applied Ultrasonic sealed housing meets IP57 water resistant for Temp RH models LED Green and Red Green LED flashing stands for logging is in process Red LED flashing stands for reading exceeds High or Low alarm threshold LCD display model shows Temperature and Relative humidity interchange The standard package supplied a USB logger unit with USB clear cap sensor cap...

Page 3: ...ontinue 4 After complete the installation press Finished A Install logger driver for Windows OS WinXP Vista Win7 Win8 Win8 1 The PL2303_Prolific_DriverInstaller_v110 exedriver is for Windows operation system follow the installation steps hereunder 1 Put the CD into CD driver in Step1 click PL2303_Prolific_DriverInstaller_v110 exe for installation the driver B Install the logger software for Window...

Page 4: ...number and go back to software 3 Click Setting Comm port select the port number as you see from step 1 then press OK button NOTE If software message box show as Pic2 Follow the next steps 1 click My computer Content in hardware content click Device manager to find the listed COMx listed under Ports COM LPT as below with red line If you may Prolific USB to Serial Comm Port it means the logger is co...

Page 5: ...emp Humidity alarm set Hi Lo Temp and Hi Lo Humidity values Red LED will flash if the current reading is over the setting 2 Select the parameter you want to record Example Total is 32K memory if choose Temp and RH sensors at the same time memory store will split to 16K for Temp 16K for RH Pic 4 Pic 3 P4 SETTING Pic 5 1 Set sample point K 1 000 multiple basis within total memory points 2 Set sample...

Page 6: ... press OK to confirm 2 In real time mode it shows STOP button instead of DOWNLOAD at the right corner Press STOP to stop real time recording Then button will change into DOWNLOAD Press DOWNLOAD for downloading data Before exit software data has to be downloaded 1 After set start mode at real time datalogger starts login records When logger records the green fan at left corner shows it is under rec...

Page 7: ...ames pic 7 pic 8 P6 Retrieve file Press OPEN FILE button to select file and show the graph Logger Status Before download data press to show ID Records Sample rate LOGGER status Unit NOTE Once button is pressed recording is inactivated Download Download data Press DOWNLOAD button data download in few seconds Graph shows automatically Please do not press DOWNLOAD button if you won t stop record NOTE...

Page 8: ...he date of purchase One year limited warranty applies to cables A Return Authorization letter must be issued before returning for any reason This warranty does not apply to defects resulting from action of the user such as misuse abuse alteration neglect improper wiring improper maintenance or repair or unauthorized modification damage resulting from leaking batteries operation outside of specific...

Reviews: