INSTRUCTIONS
● Connecting the tone generator.
In terminated working cables :
Connect one test lead to a terminated wire and the
other test lead to earth or equipment ground.(See
figure 2)
In unterminated or non-working cables :
Connect one test lead to an unterminated wire and
the other test lead to another unterminated wire.
● Depress the round on/off spring-loaded button of
the amplifier probe. The volume control switch can
be adjusted to suit the environment. Volume can be
increased to overcome noise, or decreased to
reduce interference.
● Touch the tip of the amplifier probe to the insulation
of each suspect conductor.
● Reception of tone will be loudest on the subject
wire.
● The plug receptacle is provided for connecting to a
head set or hand set.
MAINTENANCE
The amplifier probe is maintenance free except for
battery replacement. Remove the screw from the
battery compartment, replace the 9V battery and
reassemble.