This appliance shall be installed only by authorised persons and in accordance with the manufacturer's 
installation instructions, local gas fitting regulations, municipal building codes, electrical wiring regulations, 
local water supply regulations, AS/NZS 5601.1-2010-Gas Installations–General installations 
and any other 
statutory regulations. 

WARNING: It should be recalled that the appliance utilises a threaded 1/2" gas cylindrical male fitting according 
to UNI-ISO 228-1. 
 

For ease of service, the cooker should be connected with a Flexible Hose, which complies with AS/NZS 1869 (AGA 
Approved), 10mm ID, class B or D, between 1 - 1.2m long and in accordance with AS5601 for a high level connection.  

 

WARNING:

 Ensure that the hose is not subjected to abrasion, kinking or permanent deformation and should be able to 

be inspected along its entire length. Unions compatible with the hose fittings must be used and connections tested for 
gas leaks. The fixed consumer piping outlet should be at approximately the same height as the cooker connection point, 
pointing downwards and approximately 200mm - 300mm in from the left hand side of the cooker. The hose should be 
clear of the floor when the cooker is in the installed position. A hose restraint chain should be anchored to the wall to 
prevent strain on the hose connections when the cooker is pulled forward. 
 
Fit the supplied gas connectors as shown in Fig. 11 for your installation gas type. The gas inlet has a 1/2" BSP male 
thread. When making the connection, take care not to apply excessive stress by counterbalancing tightening force. 
Ensure that the available gas supply is the same as the gas type label affixed near the gas connection point. If not, 
contact Bertazzoni for a Gas Conversion Kit.  
 

Natural Gas  

The natural gas regulator supplied must be fitted for natural gas. Ensure the arrow on the regulator points towards the 
direction of the gas flow. 

Commissioning Procedure

 - The test point pressure must be adjusted to 1.00 kPa with the Wok 

Burner (both inner and outer), 1× Semi Rapid and Rapid Burner operating on maximum flame.  
 

Propane (LPG) 

Fit the LPG test point assembly (supplied in the gas conversion kit). An AGA Approved gas regulator suitable for a 
supply pressure of 2.75kPa should be part of the gas tank supply. 

 
 

ANTI-TILTING CHAIN/HOSE RESTRAINING CHAIN 

A chain should be fitted by the installer within 50mm of the hose connection point to prevent strain on the hose when the 
cooker is pulled forward. The chain should restrict the appliance movement to no more than 80% of the hose length. 
After the chain is installed, check that there is no strain on the hose or gas connections when the cooker is pulled as far 
forward as the chain allows. 
 
The cooker is also supplied with two chains which are connected to the rear left and right of the appliance. The chains 
should be connected to the wall directly behind the chains as low as possible to prevent the appliance from tilting 
forward. If the appliance is installed between two cupboards, drill a hole on each side of the cupboards, pass the chains 
through the holes and anchor the chains within each cupboard. Ensure the chain connections are strong enough to 
support the weight of the appliance and taught to prevent it from tilting forward. 
 
WARNING: In order to prevent accidental tipping of the appliance, for example a child climbing onto the open oven door, 
the stabilising means must be installed. Ensure the chains are correctly anchored to prevent the appliance from tilting 
forward and to prevent strain on the hose when the cooker is pulled forward. 
 
MAKE SURE THE ANTI-TILTING CHAINS ARE TAUGHT WHEN ANCHORED TO PREVENT THE APPLIANCE 
TILTING. 
 

ADAPTATION TO DIFFERENT TYPES OF GAS FOR COOKER TYPE M6V 

Before performing any maintenance operation, disconnect the appliance from the gas supply and electricity 
network. 

 

REPLACING THE NOZZLES TO OPERATE WITH ANOTHER TYPE OF GAS FOR COOKER TYPE M6V: 
Follow the instructions below to change the burner nozzles on the work surface: 

1) Pull out the plug from the electric outlet to avoid any type of electric contact. 
2) Remove the grids from the work surface. 
3) Remove the burners. 
4) Unscrew the nozzles using a 7 mm spanner, and replace them (Fig.12) with those needed for the new type of gas 
according to what is indicated in Table 1.

 

Follow the instructions below to change the oven burner nozzle: 

1) Remove the oven level (Fig. 13). 
2) Loosen the screw 

V

 and pull out the burner from the support being careful not to damage the ignition plug and the 

thermocouple (Fig. 14). 
3) Unscrew the nozzle 

R

 using a 10 mm spanner and replace it with the nozzle needed for the new type of gas according 

to what is indicated in Table 1  

Summary of Contents for X906 DUAL

Page 1: ...operty or to persons caused by incorrect installation or improper use of the appliance The manufacturer is not responsible for any inaccuracies due to printing or transcription errors contained in this booklet In addition the appearance of the figures reported is also purely indicative The manufacturer reserves the right to make changes to its products when considered necessary and useful without ...

Page 2: ...electrical and electronic equipment Disposal must be carried out in accordance with local environmental regulations for waste disposal For more detailed information about treatment recovery and recycling of this product please contact your local city council office INSTALLER INFORMATION The installation all adjustments transformations and maintenance listed in this part of the manual must be carri...

Page 3: ...t be clogged Indirect ventilation is also permitted by taking air from the rooms adjacent to the one to be ventilated LOCATION AND AERATION The gas cooking appliances must always evacuate the combustion products by means of hoods connected to chimneys flues or directly outside see Fig 4 If a hood cannot be installed it is possible to use a fan installed on a window or directly facing outdoors to b...

Page 4: ...ld be part of the gas tank supply ANTI TILTING CHAIN HOSE RESTRAINING CHAIN A chain should be fitted by the installer within 50mm of the hose connection point to prevent strain on the hose when the cooker is pulled forward The chain should restrict the appliance movement to no more than 80 of the hose length After the chain is installed check that there is no strain on the hose or gas connections ...

Page 5: ...y of the flame so it remains on when switching quickly from the MINIMUM to the MAXIMUM position WARNING The above mentioned adjustment should be made only with methane gas burners while for those operating with liquid gas the screw must be locked at the end in a clockwise direction The grill burner always operates at maximum and therefore no minimum adjustment is required APPLIANCE ELECTRIC CONNEC...

Page 6: ...become hot during use To avoid burns young children should be kept away For the food warmer compartment or drop leaf in our case ATTENTION The internal parts of the food warmer can become hot during use For glass doors Do not use harsh abrasive cleaners or sharp metal scrapers to clean the oven door glass since they can scratch the surface which may result in shattering of the glass Do not use ste...

Page 7: ...urners on the worktop the full dot identifies the burner in object in this case the front burner on the right the symbol shows the running of any oven ventilated gas oven with electric grill 9 positions switch the symbol shows the electric thermostat for electric oven USING BURNERS A diagram is etched on the control panel above each knob which indicates which burner corresponds to that knob The bu...

Page 8: ...the specific pages for use information FAN GAS OVEN Operating the fan of the oven by means of the appropriate switch situated on the control panel the circulation of warm air guarantees a uniform heat distribution The preheating of the oven can be avoided However for delicate baking it is preferable to warm the oven before introducing the baking pan The baking system with the fan convection change...

Page 9: ...o follow the instructions of the specific recipe being used Temperatures between brackets are referred to the use of oven with fan assisted gas TABLE N 6 GAS OVEN COOKING TABLE TEMP C HEIGHT MINUTES MEAT PORK ROAST 220 210 3 60 70 BEEF ROAST YOUNG STEER 250 240 3 50 60 BEEF ROAST 240 230 3 60 70 VEAL ROAST 220 210 3 60 70 LAMB ROAST 220 210 3 45 55 ROAST BEEF 230 230 3 55 65 ROAST HARE 235 225 3 4...

Page 10: ...ctric fan have been turned on the symbol indicates that the grill element 2500W and the electric fan have been turned on the symbol indicates that only the grill element 2500W has been turned on the symbol indicates that only the electric fan has been turned on When the knob is set to one of these five positions the oven light is always on thus indicating that the oven is being energised When 5 0 ...

Page 11: ...s or the tray To keep the oven as clean as possible it is recommended to cook meat on the tray or on the shelf that has been inserted inside the tray Table No 7 below lists the cooking times and the position of the tray for different types of foods Personal experience will help to determine any variations in the values reported in the table In any case it is recommended to follow the instructions ...

Page 12: ...OSE 160 180 3 120 160 ROAST DUCK 170 180 2 100 160 ROAST CHICKEN 180 2 70 90 FISH 160 180 2 3 PASTRY FRUIT PIE 180 200 2 40 50 TEA CAKE 200 220 2 40 45 BRIOCHES 170 180 2 40 60 SPONGE CAKE 200 230 2 25 35 RING CAKE 160 180 2 35 45 SWEET PUFF PASTRIES 180 200 2 20 30 RAISIN LOAF 230 250 2 30 40 STRUDEL 160 2 25 35 SAVOIA COOKIES 150 180 2 50 60 APPLE FRITTERS 180 200 2 18 25 SAZOIARDI SANDWICH 170 ...

Page 13: ... in any case ABNORMAL OPERATION Any of the following are considered to be abnormal operation and may require servicing Yellow tipping of the burner flame Burners failing to remain alight Sooting up of cooking utensils Burners extinguished by cupboard doors Burners not igniting properly Gas valves which are difficult to turn In case the appliance fails to operate correctly contact Bertazzoni CLEANI...

Page 14: ...sed personnel For this reason we strongly advise you contact the Bertazzoni Service Center specifying the nature of the problem the model of the equipment and the serial number This data is provided on the data label adhered to the base of the appliance and on the duplicate data label Always use original Bertazzoni spare parts BERTAZZONI GROUP ABN 38 069 686 326 650 Bridge Road Richmond Victoria 3...

Page 15: ...15 Fig 1 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 ...

Page 16: ...16 Fig 8 Fig 9 Fig 10 Fig 11 Fig 12 Fig 13 Fig 14 ...

Page 17: ...17 Fig 15 Fig 16 Fig 17 T Fig 18 Fig 19 Fig 20 Fig 21 Fig 22 Fig 23 Fig 24 Fig 25 ...

Page 18: ...18 Fig 26 Fig 27 Fig 28a Fig 28b Fig 28c Fig 28d ...

Page 19: ...19 Fig 29 Fig 30 Fig 31 Fig 32 ...

Page 20: ...20 OVERALL DIMENSIONS Cod 310686 ...

Reviews: