Bertazzoni B3H0..Q7X2D Type A Installation, Service And User Instructions Manual Download Page 7

 

7

For the location of the wall receptable for the connection of the three-pin earthed plug of the 
appliance, see indications given in Fig. 1- 2  

WARNING: After first installation of the appliance or after any service intervention concerning main 
gas parts of the appliance, make the leak test using water with soap on the gas connections in order 
to verify the correct installation. Do not use fire for gas leak testing. 

 

Greasing the valves

 

If it becomes difficult to operate the valve, it should be greased immediately by following the instructions 
listed below 
1. Disassemble the valve body by loosening the two screws located on the body of the valve. (See Fig. 15). 
2. Extract and clean the seal cone and its housing with a rag soaked with thinners. 
3. Lightly grease the cone with a special grease. 
4. Insert the cone, moving it several times, remove it again, remove the excess grease and make sure that 
the gas passage ways are unobstructed. 
5. Replace all the pieces in reverse order and check that the valve operates correctly. 

User instructions 

WARNINGS:

  

Keeping appliance area clear and free from combustible materials, gasoline and other flammable 
vapors and liquid. 

 

Do not store dangerous or flammable material in the cabinet areas above appliance; store them in a 
safe place in order to avoid potential hazards. 

For safe use of appliance, do not use it for space heating.  
Do not use aerosol sprays in the vicinity of this appliance while it is in operation 

For description of hotplates refer to installation instructions. 

Using burners

 

A diagram is etched on the control panel above each knob which indicates which burner corresponds to that 
knob. 

Manual ignition:

 

Manual ignition is always possible even when the power is cut off or in the event of prolonged power failure. 
Turn the knob that corresponds to the burner selected counterclockwise to the MAXIMUM position at the 
etched star (large flame) and place a lit match up to the burner. 

Automatic electric ignition:

 

Turn the knob that corresponds to the burner selected counterclockwise to the MAXIMUM position at the 
etched star (large flame) and then press the knob down to activate the spark ignition. Release the knob 
some second after the burner has ignited. 

Burners fitted with a safety device (thermocouple):

 

Turn the knob that corresponds to the burner selected counterclockwise to the MAXIMUM position at the 
etched star (large flame) and then press the knob down to activate the spark ignition. Once ignited, keep 
pressing the knob for about 10 seconds to allow the flame to heat the thermocouple. If the burner does not 
remain alight after releasing the knob repeat the above procedure, 

Use of the Dual burner (Fig.16) 

This model controls both the central and the external crown of the burner with just one valve. 
To ignite the central crown and the external crown of the burner, press and turn the knob to the maximum 
delivery position 1  
and hold it down until ignition; in this position both the internal and the external flame are at maximum. 
Turn the knob to position 2 to have the external crown at minimum and the internal crown at maximum flame 
Turn the knob to position 3 to have the internal crown at maximum and the external crown off 
Turn the knob to position 4 to have the internal crown at minimum and the external crown off. 

Summary of Contents for B3H0..Q7X2D Type A

Page 1: ...o not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas suppliers call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Read this instruction booklet before installing and using the a...

Page 2: ...en moving the cooktop The pressure regulator has female pipe thread You will need to determine the fitting required depending on the size of your gas supply line the flexible metal connector and the shutoff valve The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 The appliance and...

Page 3: ...all be installed in accordance with the manufacturer s instructions However in no case shall the clearance between the top of the highest burner of the cooking appliance and the range hood be less than 25 1 2 650mm Any other downward facing combustible surface less than 600mm above the top of the highest burner shall be protected for the full width and depth of the cooking surface area However in ...

Page 4: ...WHEN CONNECTING THE SUPPLY DO NOT OVER TIGHTEN The regulated pressure For NG is 4 w c See Fig 5 6 For gas inlet position of appliance refer Fig 5 6 and 7 After installing the gas supply and making all connections check thoroughly for possible leaks Turn all control knobs on the unit to OFF position Open the valve on the gas supply Using a soap and water solution check each gas connection one at th...

Page 5: ...OF GAS To change the nozzles of the burners use the following procedure Lift up the burners and unscrew the nozzles Fig 8 using an adjustable spanner of 7 mm and change the nozzles with those designed for the new gas supply according to the information given in TABLE A shown below TABLE A Adapting to different types of gas Drop in cooktop with 5 workyop burners model B3H0 Q7X 2 or 5 D Burner Posit...

Page 6: ...as different from which one it is pre arranged it is enough perform the following operations 1 Unscrew by hand the upper metal stopper of the regulator Fig 5 2 Unscrew by hand the white plastic piece screwed under the above mentioned metal stopper afterward screw it again in opposite way under the metal stopper for gas reference see the written LP and NAT with relative indicating arrows on the whi...

Page 7: ... etched on the control panel above each knob which indicates which burner corresponds to that knob Manual ignition Manual ignition is always possible even when the power is cut off or in the event of prolonged power failure Turn the knob that corresponds to the burner selected counterclockwise to the MAXIMUM position at the etched star large flame and place a lit match up to the burner Automatic e...

Page 8: ...re proper ventilation in the room is needed and natural ventilation openings must remain unobstructed and activating the mechanical exhaust fan range hood Intensive and continuous use of the appliance may require additional ventilation for example by opening a window or increasing the power of the mechanical exhaust fan range hood if installed Cleaning the appliance Never use abrasive cleaners Bef...

Page 9: ...e service Dealer Importer Name address phone MANUFACTURER BERTAZZONI SPA VIA PALAZZINA 8 42016 GUASTALLA REGGIO E ITALY Tel 0522 226411 telefax 0522 226440 http www bertazzoni italia com SERVICE CENTERS Name Phone ...

Page 10: ...ez aucun interrupteur électrique N utilisez aucun téléphone dans votre établissement Appelez immédiatement votre fournisseur de gaz par le téléphone d un voisin Suivez les instructions du fournisseur de gaz Si vous ne pouvez pas atteindre vos fournisseurs de gaz appelez les pompiers L installation et le service doivent être exécutés par un installateur qualifié une agence de service ou par le four...

Page 11: ... ou CGA de 1 5 mètres de longueur maximum I D recommandé pour le branchement de cette table de cuisson au conduit d amenée des gaz Ne pliez pas ou n endommagez pas le connecteur flexible en déplaçant la table de cuisson Le régulateur de pression a un filetage au pas du gaz femelle de Vous devrez déterminer le raccordement demandé selon la dimension du conduit d amenée des gaz du connecteur en méta...

Page 12: ...er une ouverture dans la surface supérieure du banc de travail mesures relatives selon la Fig 1 2 Exigences 1 Distances des meubles suspendus Valeurs minimum Les distances minimum devront être conformes aux valeurs minimum indiquées dans la table n 1 et sont illustrées dans la fig 1 2 Les hottes de cuisine et les ventilateurs aspirant doivent être installés selon les instructions du fabricant Cepe...

Page 13: ...ement d entrée a un filetage mâle de 1 2 B S P filetage Whitworth pour tuyaux IL EST ESSENTIEL QUE LE COUDE SUR L APPAREIL SOIT FERMEMENT RETENU AVEC UNE CLE LORSQU ON BRANCHE L ALIMENTATION NE PAS SERRER La pression réglée pour GN est de 4 colonne d eau Voir Fig 5 6 Pour la position d entrée du gaz de l appareil référez vous à la Fig 5 6 et 7 Après avoir installé l alimentation du gaz et après av...

Page 14: ...eut avoir influence sur les autres appareils a gaz qui functionnent dans le meme local en chaque cas elle doit etre eventuellement installée conformement aux normes nationals en vigueur Conversion à différents types de gaz Avant d effectuer n importe quel travail d entretien débranchez l appareil de l alimentation gaz et électrique Pour le Gaz Naturel utilisez le régulateur illustré en Fig 5 Pour ...

Page 15: ...MINIMUM 4 S assurer que la flamme ne sorte pas en changeant rapidement la position du MAXIMUM en position de MINIMUM ATTENTION Le réglage décrit ci dessus peut être seulement effectué avec des brûleurs qui emploient le gaz naturel tandis qu avec les brûleurs qui emploient le gaz propane la vis doit être complètement vissée dans le sens des aiguilles d une montre Adaptation du régulateur de pressio...

Page 16: ...ssurant de cette façon l étanchéité parfaite entre le corps et le train de gaz ATTENTION Débranchez l alimentation avant l entretien de l unité Pour le positionnement de la prise au mur pour le branchement de la bonde de mise à terre à trois pôles de l appareil voir les indications illustrées en Fig 1 2 ATTENTION Après la première installation de l appareil ou après n importe quelle intervention d...

Page 17: ...lumé après avoir relâché le bouton répétez le procédé ci dessus Utilisation brûleur Dual fig 16 Ce modèle commande avec un seul robinet tant la couronne centrale du brûleur que la couronne externe Pour allumer la couronne centrale et la couronne externe du brûleur il faut appuyer sur la manette puis la tourner sur la position 1 de distribution maximum et la maintenir pressée jusqu à l allumage dan...

Page 18: ...oyer abrasifs Avant de nettoyer l appareil il doit être débranché du réseau électrique Nettoyage de la surface de travail nettoyez périodiquement les têtes des brûleurs les supports en acier émaillés des casseroles et les chapeaux des brûleurs en utilisant de l eau chaude Tout débordement devra être enlevé aussitôt que possible en utilisant un chiffon S il est difficile d ouvrir ou fermer une valv...

Page 19: ... vente Revendeur Importateur Nom adresse téléphone FABRICANT BERTAZZONI SPA VIA PALAZZINA 8 42016 GUASTALLA REGGIO E ITALY Tél 0522 226411 fax 0522 226440 http www bertazzoni italia com CENTRES DE SERVICE Nom Téléphone ...

Page 20: ...20 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 ...

Page 21: ...21 Fig 7 Fig 8 Fig 9 Fig 10 Inches mm A 1 11 16 43 B 1 3 16 30 C 1 1 16 27 E 4 7 16 112 ...

Page 22: ...22 Fig 11 Fig 12 Fig 13 Fig 14 Fig 15 ...

Page 23: ...23 Fig 16 Fig 17 ...

Reviews: