14
ELECTRICAL CONNECTION
The appliance shall be connected to a single
phase electric line rated at 120/208Vac or
120/240Vac and 60Hz frequency.
Electric power rating:
‐
120/208Vac: 6700 Watt or 32 A max.
‐
120/240Vac: 8500 Watt or 37 A max.
Heating elements (240V)power rating:
LEFT OVEN:
‐
Oven bake element = 2100 Watt
‐
Oven circular element = 3300 Watt
‐
Oven broil element = 3400 Watt
RIGHT OVEN:
‐
Upper + broil element = 900+1100 Watt
‐
Bottom element = 900 Watt
WORKTOP ELE. GRIDDLE ELEMENT = 1100 Watt
Install a suitable electric power supply receptacle
connection type NEMA 14
‐
50R able to support a
load of at least 40 A (per line) according to local
code requirements. For four or three wires power
supply connection system see diagram below.
FOUR-WIRE CONN.RECEPTACLE NEMA 14-50R
THREE-WIRE CONN.RECEPTACLE NEMA 14-50R
Check your local code for which of the options
below should be used in grounding the
receptacle power supply connections.
OPTION 1 – FOUR Wires connection:
‐
Connect the L1 receptacle terminal to the
incoming BLACK electrical supply wire (L1
‐
hot
wire)
‐
Connect the L2 receptacle terminal to the
incoming RED electrical supply wire (L2
‐
hot
wire)
‐
Connect the NEUTRAL receptacle terminal to
the incoming NEUTRAL (WHITE) electrical
supply wire
‐
Connect the GROUND receptacle terminal to
the incoming GROUND (GREEN) electrical
supply wire
OPTION 2 - THREE-Wires connection:
‐
Connect the L1 receptacle terminal to the
incoming BLACK electrical supply wire (L1
‐
hot
wire)
‐
Connect the L2 receptacle terminal to the
incoming RED electrical supply wire (L2
‐
hot
wire)
‐
Connect the NEUTRAL with the GROUND
receptacle terminal to the incoming NEUTRAL
(WHITE) electrical supply wire
DO NOT USE EXTENSION CORDS WITH THIS
APPLIANCE AS IT MAY RESULT IN FIRE,
ELECTRIC SHOCK OR OTHER type of
PERSONAL INJURY.
The appliance is equipped at the factory with an
electric supply cord set 4 wires type with ring
terminals (L1, L2, N, Ground) suitable for range
use UL/CSA listed type SRDT/DRT 2x6AWG (L1,
L2)+2x8AWG (N, G) rated 300V, 40 or 50A with
fused plug type NEMA 14
‐
50P; cable length 1,5
m.; in case the supply cord set must be replaced,
it shall be replaced with an identical set having
the same technical specs and following carefully
the instructions and diagrams below:
1) Disconnect appliance from electrical power
supply receptacle
2) Slide out the appliance from installation place
to access to back enclosure panel
3) Remove back enclosure panel by removing
the 6 screws as shown below
Summary of Contents for A486GPIRBI
Page 15: ...15 4 Loose strain relief by unscrewing the two strain relief s screws as in diagram ...
Page 17: ...17 WIRING DIAGRAM LEFT OVEN GAS TOP IGNITION ...
Page 18: ...18 RIGHT OVEN GRIDDLE ...
Page 44: ...44 BERTAZZONI SpA Via Palazzina 8 42016 Guastalla RE ITALY WWW BERTAZZONI ITALIA COM ...
Page 49: ......
Page 50: ......
Page 51: ......
Page 52: ......