10
- CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS:
To change the nozzles of the burners use the following procedure:
Lift up the burners and unscrew the nozzles ( Fig.) using an adjustable spanner of 7 mm and change the nozzles with
those designed for the new gas supply according to the information given in TABLE shown below.
Models
CTYK..U7X(2, 5)A
Adapting to different types of gas
Burner
Position
Injector
Gas
Pressure
Max Rate
Min Rate
By-pass
diam. [mm.]
Type
[i.w.c.]
[BTU/h]
[W]
[BTU/h]
[W]
diam. [mm]
Auxiliary Front
R 0,92
NG
4”
3750
1098
900 264
Regulated
0,56
LP
(Propane)
11”
3750
1098
900
264
0,29
Semi-Rapid
Rear L & C
1,17
NG
4”
6000
1759
1500
439
Regulated
Front
C
0,73
LP
(Propane)
11”
6300
1845
1500
439
0,36
Rapid Rear
R 1,55
NG
4”
10400
2046
2500
732
Regulated
0,98
LP
(Propane)
11”
11400
3339
2500
732
0,47
Front L Inner
0,80
NG
4”
2730
799
900
264
Regulated
Dual Burner
0,50
LP (Propane)
11”
2900
8479
900
264
0,29
Front L Outer
N°2 x 1,30
NG
4”
15000
4394
4500
1319
Regulated
N°2 x 0,83
LP (Propane)
11”
16400
4804
4500
1319
0,65
CAUTION: save the orifices removed from the appliance for future use