Operating 

Cooking 

The unit can be used immediately. If the operation indicator lamp lights and the LED shows 

(1-9) continuously or flashes, energy is transferred to the pan. By turning the power control 

knob, you can choose the desired power level (1-9). How much inductive power is transferred 

to the pan depends to the choosed power level. 

 

 

Position MINIMUM  

Minimum Performance 

 

Position MAXIMUM 

Maximum Performance 

 

Because of the following circumstances, you  must  pay more attention to the  unit  when 

cooking with conventional cooking systems. If the performance  step  is changed with the 

power control knob, the cooking material reacts immediately.  Empty pans or pots heat up 

very quickly. NEVER place empty pans on the glass ceramic hob. First fill the cook ware 

with food, fat or liquid and then start cooking. Use the power control knob to select the exact 

power level that matches the desired cooking method.  The pan should always be placed in 

the center of the heating zone (except devices with 

flächen

star coil), or the pan bottom will 

be heated unevenly. Check the pan continuously when heating oil or grease to prevent it 

from overheating or burning. 

 

 

 

 

 

 

 

 

 

 

 

 

Comfort 

The induction equipment only transfers energy as long as a pan is located on the heating 

zone. This is independent of the position of the power step (1-9). When you remove a pan 

from the heating zone, the energy transfer to the pan is stopped immediately. When you put 

the pan back in the heating zone, the energy level you have selected before is transferred 

again to the pan. When turning the power control knob to the OFF position, the cooking 

process is stopped. However, the equipment still stays ready for work (standby mode). To 

disconnect the unit completely, you must disconnect the unit from the main supply or turn 

the Main switch off (if available). 

 

Software Version 

Aufstarten des Generators 

second

 

explanation 

8. (Test of the segments) 

F or P (Operation Frequency or Pulse)

 

2. (Software version first digit) 

1 (Software Version 2

nd

 digit) 

9 (Software Version third digit) 

 

Normal use 

Standby: if the performance controller is in OFF position, the point flashes all 2 seconds. If 

the performance controller is in ON position, first the cook ware is searched U and the point 

flashes (after 1 Minute standby modus: search pulse all 5 seconds). 

 

If a cook ware is detected, the digital display shows the chosen performance step (1–9). 

 

Significance of the decimal point: 

ON 

Normal USE 

1 sec. pulse  

=   Limitation: because to high heat sink temperature  

½ sec. pulse  

=   Limitation: because to high coil / cook ware temperature 

¼ sec. pulse 

=   Power limitation 

1/10 sec. pulse   =   Power limitation if not optimal cook ware material 

 

 

Don´t place hot cook ware on the control panels, displays or frames of the unit. To ignore 

the points, follows to damages of the unit and the cookware. Consequence of ignore: 

The warm cookware burning the seal material and the material get destroyed. This result 

humidity and grease can penetrate in the equipment and can result in the defect of the 

Equipment and raise the risk of an electric shock. Cookware will be welded together with 

the surface or frame. Overheating of the displays and control surfaces leads to damages.  

 

Summary of Contents for BI1EG2.5B

Page 1: ...tions for use and installation instructions before to start the installation build in commissioning Thereby protecting yourself and avoid damages Berner Kochsysteme GmbH Co KG Sudetenstrasse 5 D 87471...

Page 2: ...e generator BIPDS BIPDMS 10 Installation 11 Electrical data of the units 11 Unit performance 3 5 kW BIPMS3 5 11 Unit performance 5 kW BIPMS5 11 Unit performance 5 kW 7kW 8kW 9kW BIPS 11 Unit performan...

Page 3: ...nting frame Ver B 30 Air Chanel module separated 30 Observe the installation regulations 31 Installation regulations 31 Additional installation regulations for the mounting model 32 Additional install...

Page 4: ...king zone surroundings also the outside frame getting hot Don t touch these hot surfaces Keep children away The cooking zone is working but the display is off Disconnect the unit from the main supply...

Page 5: ...uctions may lead to danger for people the surroundings and the induction unit itself We are not liable for any damages caused by a failure to observe the safety instructions In detail ignore of the sa...

Page 6: ...per carton textiles etc between the pan and the ceramic hob they could catch fire Aluminium foil and plastic containers may not be placed on the hot surfaces Don t place metal objects on the cooking z...

Page 7: ...s before the equipment is installed and taken into operation They must always be kept close to the cooking site for reference Application The induction units have been designed for the preparation of...

Page 8: ...EG 14 20 28 D14 20 A B 700 x 700 mm 650 x 650 x 6 mm BI4EGDF 14 20 28 A B 700 x 700 mm 650 x 650 x 6 mm BI4EG 14K 20K D14K D20K A B 700 x 650 mm 650 x 605 x 6 mm BI4EGDF 14K 20K 28K A B 700 x 650 mm 6...

Page 9: ...x 280 400V 3 PE 7 0 10 0 kW 20 25 kg BI2EGF14K BIPS5 2 x 280 400V 3 PE 14 0 kW 25 kg BI2EGF 10W 14W BIPS5 2 x 300 x 280 400V 3 PE 10 0 14 0 kW 25 25 kg BI2EG3 5SK BIPDMS3 5 2 x 230 230V 1 N PE 3 5 kW...

Page 10: ...8 0 kW 47 47 kg BI4EGLS 20 32 BIPS5 4 x 320 400V 3 PE 20 0 32 0 kW 47 47 kg BI4EGLSM 9 13 BIPDS 4 x 320 400V 3 PE 32 0 32 0 kW 47 47 kg BI4EGLK 20 24 BIPS5 2 x 300 270 400V 3 PE 20 0 24 0 kW 45 45 kg...

Page 11: ...e kW 0 0 8 1 8 7 5 3 0 0 1 10 9 2 5 8 75 3 5 1 0 13 1 3 0 10 0 4 0 1 1 15 3 3 5 12 5 5 0 Performance table 3 phases generator Sw1 4 5 Type 400V electricity A Performance kW Type 230V electricity A Per...

Page 12: ...6A F super quick N Blue or 4 Working frequency 22 35 kHz Control fuse PE Yellow Green Unit performance 10 kW BIPDS Induction unit 3 phases Voltage 400Volt 5 10 Connection colour Frequency Fuse Phase B...

Page 13: ...ult current circuit breakers they must be designed for a minimum fault current of 30 mA Avoid blocking the air inlet and outlet zones with objects textiles walls etc Prevent hot ambient air from being...

Page 14: ...ive panels etc is recommended that these are not made of flammable material otherwise they must be covered with suitable non combustible heat insulating material and the fire safety regulations must b...

Page 15: ...on optional How do i work with the keep warm function To use this function with knob W70 W110 or with the touch control panel If the keep warm function is active please take ACCOUNT that the cookware...

Page 16: ...With the function button can be switched between performance control in full range and keep warm function Examples Performance control halve step 4 5 5 0 5 5 From software version 2 28 If there is no...

Page 17: ...e pan With digital display 1 9 Remove the pan from the heating zone The digital display shows symbol for pan detection see error messages Put the pan back on the heating zone The digital display shows...

Page 18: ...e energy level you have selected before is transferred again to the pan When turning the power control knob to the OFF position the cooking process is stopped However the equipment still stays ready f...

Page 19: ...d on SW1 8 on the control board On the generator a second potentiometer are connected to the generator of the cooking place This potentiometer has now a master function for generators The potentiomete...

Page 20: ...unit faulty Contact your dealer for the repair service Disconnect the unit from the power supply No reaction by changing the value with the controller knob Performance controller faulty Heating up tu...

Page 21: ...Temperature sensor heat sink shorted Missing Potentiometer or Sub break of Potentiometer Wrong value 10 75 kOhm Potentiometer OFF Residual heat indicator cooking zone temperature 45 C Signal for exte...

Page 22: ...ning Razor blade Non abrasive sponge Do not use abrasive cleaning agents steel wool or abrasive sponges since these may damage the ceramic surface Residues of cleaning agents must be removed from the...

Page 23: ...misuse The equipment can t be used by someone who is not qualified to do Make sure that an induction unit you want to dispose of can t take into operation again The induction unit consists of common e...

Page 24: ...to the unit this declaration loses its validity Meets the requirements that the approximation of the legislation of the Member States In the EC directive Low voltage 2006 95 EG from 12 December 2006...

Page 25: ...Page 24 of 44 17 07 2014 Ver 3 3 Berner Kochsysteme 2015 Generator Views...

Page 26: ...Page 25 of 44 17 07 2014 Ver 3 3 Berner Kochsysteme 2015 Spare Parts List BIPS Generator...

Page 27: ...Page 26 of 44 17 07 2014 Ver 3 3 Berner Kochsysteme 2015 BIPMS Generator...

Page 28: ...Page 27 of 44 17 07 2014 Ver 3 3 Berner Kochsysteme 2015 BIPDS Generator...

Page 29: ...Page 28 of 44 17 07 2014 Ver 3 3 Berner Kochsysteme 2015 BIPDMS Generator...

Page 30: ...Page 29 of 44 17 07 2014 Ver 3 3 Berner Kochsysteme 2015 Displays in different versions...

Page 31: ...of 44 17 07 2014 Ver 3 3 Berner Kochsysteme 2015 Technical Documentation View for flush mounting frame Ver B Air Chanel module separated Air channel module Air channel coil generator separated Standin...

Page 32: ...aged glass ceramic immediately otherwise there is the danger for penetrating Liquid into unit The Liquid leads to damage of the unit Installation regulations The following points have to be follow Exa...

Page 33: ...d cleanly on both sides The net separator should be turned off not more than 5 times a day Additional installation regulations coil generator separated Prolong with connectors and 6mm Radox Wire 155 C...

Page 34: ...uidelines will void the warranty Making the cut in the surface in accordance with the installation drawing Please only use detailed drawings Use only suitable materials stainless steel at least 3mm or...

Page 35: ...ckup of the system Grease filter with mounting frame for attachment to the revision plate The revisions plate has to be removable Install of the revisions plate removable in case of service with the c...

Page 36: ...Please use only detailed drawings Use only suitable materials stainless steel at least 3mm or granite Install the bolts M6 on the bottom on the surface shown in the diagram installation drawing mounti...

Page 37: ...sion of the coil to keep the glass ceramic plate on the inner frame Keep the weight on the place until the adhesive is cured To adjust the glass ceramic plate to the same level like the surface use th...

Page 38: ...rame inclusive electronic is pre assembled with glued glass ceramic Please follow the instruction on page 33 Please observe the following installation instructions The only way to ensure a trouble fre...

Page 39: ...Frame inclusive electronic is pre assembled with glued glass ceramic Please follow the instruction on page 33 Please observe the following installation instructions The only way to ensure a trouble fr...

Page 40: ...sive electronic is pre assembled with glued glass ceramic 2 3 mm standing out Please follow the instruction on page 35 Please observe the following installation instructions The only way to ensure a t...

Page 41: ...QM7 http sdrv ms 1gG2jzV BI1EGSF8 http sdrv ms 1fIiyL4 BI4EGV32 http 1drv ms 1sac0jk BI1EGSPW http sdrv ms LYPg2n BI4EGVM9 http 1drv ms 1sahF97 BI1EGSPW2 http 1drv ms 1nY8KDg BI4EGVM13 http 1drv ms Xt...

Page 42: ...2EGAR14 http 1drv ms 1fLgfeu BI3EGQ15 http 1drv ms 1dsXXsq BI4EGA14 http sdrv ms 1dwvfdg BI3EGQF10 http 1drv ms 1fou3eE BI4EGA20 http sdrv ms 1cu3hu5 BI3EGQF15 http 1drv ms 1flKrXt BI4EGA28 http 1drv...

Page 43: ...BI2EGLS16 http 1drv ms 1cZjk4l BI6EG21K http 1drv ms 1foHOKb BI2EGLSM5 http 1drv ms 1gaPZG7 BI6EG30K http 1drv ms 1dtFSug BI2EGLSM7 http 1drv ms 1iZTBAs BWEB2Q10 http sdrv ms 1coUCKt BWEB3 5 http sdrv...

Page 44: ...Page 43 of 44 17 07 2014 Ver 3 3 Berner Kochsysteme 2015 Wiring diagram...

Reviews: