Page 5/7
03-2015
Designation terminal
6
3
2
1
Assignment
S
Table 2: Assignment on the terminal block (1) of the WLAN Access-Point
Figure 4
WLAN Access-Point, PoE (order no. 4583)
Connect network cable
Run the mains cable preferably into the wall box from below.
Shorten the cable to a length of approx. 90 mm from the bottom of the wall box.
Strip the cable to approx. 80 mm. When doing so, keep the pair shielding and twist of the
pair and wires as far as possible.
Twist the outer shielding
S
and affix it in a conductor sleeve (1 mm²) if necessary.
Pull off 9pole terminal block (2) from the device and lay the wires according to the prescribed
colour coding (Table 3).
The assignments on the terminal block (2) must match those of the patch panel in the net
-
work.
Mount terminal block onto the contact pins (3) (Figure 5).
Mount the device into the wall box.
Unscrew cover.
Device with the factory settings is ready for operation. A configuration for individual settings
can be made.
WLAN Access-Point flush-mounted
6LE001255A