Berker 2912 Quick Start Manual Download Page 5

picture 3: Adjuster for run-on time of output HLK 

(1)  Flush-mounted insert 
(10) Adjuster for run-on time of output 

HLK 

Turn adjuster (10) to the desired time. 

6 Appendix 

6.1 Technical data 

Rated voltage 

AC 230 V ~ 

Mains frequency 

50 / 60 Hz 

Ambient temperature 

+5 ... +35 °C 

Circuit breaker 

max. 10 A 

Contact type 

µ contact 

Switching current at 25 °C, Kanal 1 
Ohmic 

10 A 

Switch-on current max. 4 s at 10% switch-on 
time 

15 A 

Minimum switching current AC 

100 mA 

Connected load at 25 °C, Kanal 1 
Incandescent lamps 

1000 W 

HV halogen lamps 

1000 W 

Inductive transformers 

750 VA 

Tronic transformers 

750 W 

Fluorescent lamps, uncompensated 

500 VA 

Electronic ballast 

Type-dependent 

Connection, Kanal 1 
Single stranded 

max. 4 mm² 

finely stranded without conductor sleeve 

max. 4 mm² 

finely stranded with conductor sleeve 

max. 2.5 mm² 

HLK 
Follow-up time 

approx. 2, 10, 30, 60, 120 min 

Switching voltage 

AC 230 V ~ 

Minimum switching voltage 

AC 12 V~ 

Switching current for AC 230 V ~, 25 °C, HLK 
Ohmic 

6 A 

Switch-on current 

max. 2.1 A 

Minimum switching current AC 

100 mA 

Connected load for 230 V ~, 25 °C, HLK 
Incandescent lamps 

800 W 

HV halogen lamps 

750 W 

Seite 5/6 

30.07.2010 

82541321 
97-09545-000 

BLC 
BLC relay insert HVAC 

Summary of Contents for 2912

Page 1: ... the device or load Danger of electric shock Device is not suitable for disconnection from supply voltage Danger of electric shock on the SELV PELV installation Not suitable for switching SELV PELV voltages Danger of electric shock Do not operate the insert without a cover These instructions are an integral part of the product and must remain with the end customer 2 Device components picture 1 1 F...

Page 2: ...cted Output remains switched on as long as motions are detected Output is switched off if no more motions are detected and the run on time set on the insert has elapsed Behaviour after a mains voltage failure Less than 0 2 seconds switching state is retained longer than 0 2 seconds both channels switch off The behaviour after mains voltage return depends on the cover used see instructions for the ...

Page 3: ... operated Switching off in combination with motion detector or presence detector i Combination with motion detector outputs cannot be switched off i Combination with presence detector the output HLK cannot be switched off Outputs are switched on o Press extension Output Kanal 1 switches off for 3 minutes Any motions that are detected extend the time During these 3 minutes output Kanal 1 can only b...

Page 4: ...an be fatal Before carrying out work on the device or load disengage all the corresponding circuit breakers Cover up live parts in the working environment Switching switch on delay for output HLK on and off The switch on delay for output HLK can be switched on or off In the sate as delivered the switch on delay is switched on There is a pushbutton cover see Accessories on the HLK insert Outputs Ka...

Page 5: ...nt lamps 1000 W HV halogen lamps 1000 W Inductive transformers 750 VA Tronic transformers 750 W Fluorescent lamps uncompensated 500 VA Electronic ballast Type dependent Connection Kanal 1 Single stranded max 4 mm finely stranded without conductor sleeve max 4 mm finely stranded with conductor sleeve max 2 5 mm HLK Follow up time approx 2 10 30 60 120 min Switching voltage AC 230 V Minimum switchin...

Page 6: ... of the BLC system can be fitted on the BLC insert The insert can also be integrated into a radio bus installation with a BLC radio button 6 3 Warranty We reserve the right to make technical and formal changes to the product in the interest of technical progress Our products are under guarantee within the scope of the statutory provisions If you have a warranty claim please contact the point of sa...

Reviews: