Berkeley 7LT2 Owner'S Manual Download Page 2

Deep Well Installation

Under certain conditions, horizontal multi-

stage pumps can develop extremely high
pressure. Install a pressure relief valve

capable of passing entire pump flow at 75 PSI.

Do not allow pump, pressure tank, piping, or any

other system component containing water to freeze.
Freezing may damage system, leading to injury or flood-
ing. Allowing pump or system components to freeze will
void warranty.

NOTICE: 

Support pump base to avoid strain on casing adapter

or pump. Lack of support can damage adapter or pump.

Figure 2 shows casing adapter bolted directly to pump body.

Shallow Well Installation

NOTICE: 

If no foot valve is used, install 1” check valve in

horizontal line.

Priming the Deep Well Pump

To prime pump, completely close the priming valve located
just below the suction opening by turning screw clockwise.
This valve will be left closed during operation in a deep well
installation. See Figure 1.

Close regulator adjusting valve, located on end of regulator,
by turning stem clockwise. See Figure 1.

Remove priming plug from top of regulator valve, see Figure
1, and fill with clean water. Replace plug.

Start pump and run a few moments.

If pressure does not build up, remove priming plug and refill
with more water. All of the trapped air in pump body was not
removed.

Restart pump.

When pump is completely primed and builds up pressure,
slowly open the regulator valve, (turn counter-clockwise), and
observe the pressure reading on the pressure gauge.

When the pump reaches a point where it will lose prime, cavi-
tation noise can be heard.

The best, or correct, pressure gauge setting is approximately
3 pounds higher than the pressure gauge reading was when
the pump started to lose prime.

If pump loses prime, repeat the priming procedure above and
this time open regulator valve only until the correct pressure
reading is reached.

If a vacuum gauge is available, screw it into the 1/8” AVC
tapping on front of tank body. Adjust regulator until 20” of
vacuum is registered on the gauge. Tighten locknut on regu-
lator. This method will give maximum performance of the
unit.

Pumps come equipped with 30-50 PSI pressure switches.
When pump is used with precharged tank in system, set tank
pre-charge at 28 PSI. Check tank pre-charge annually with
an ordinary tire gauge. Pre-charge is set with no water pres-
sure on system.

2

Priming

Valve

Pipe fittings not furnished

Drain

Plug

Drive Line

Suction 

Line

Plastic Pipe
Adapter (2)

Plastic Hose

      (2)

Hose Clamp

      (2)

To Service

Regulator Adjusting
Valve

Priming Plug

Regulator
Valve

1" Close nipple &
90 Elbow

27

8

 1093

To Service

Priming Plug

Regulator
Valve

279 1093

Figure 1 – Deep Well Installation

Figure 2 – Well Casing Adapter bolted directly 

to pump

Summary of Contents for 7LT2

Page 1: ...MPORTANT For best possible performance continuous satisfactory operation read these instructions before installing your new pump Should service be required this manual can be a valuable guide It shoul...

Page 2: ...apped air in pump body was not removed Restart pump When pump is completely primed and builds up pressure slowly open the regulator valve turn counter clockwise and observe the pressure reading on the...

Page 3: ...imed close the priming valve during operation as a shallow well pump Service Draining for Winter Do not touch an operating motor Modern motors are designed to operate at high temperatures To avoid bur...

Page 4: ...Can shock burn or kill Connect ground wire before connecting power supply wires Use the wire size including the ground wire speci fied in the wiring chart If possible connect the pump to a separate b...

Page 5: ...on Connection Procedure 1 Connect the ground wire first as shown in Figure 6 The ground wire must be a solid copper wire at least as large as the power supply wires 2 There must be a solid metal conne...

Page 6: ...6 1 2 4 5 6 7 8 9 10 10A 10B 22 25 23 24 3 225 0993 8 11 12 12A 12B 13 14 15 16 17 18 18A 19 20 21 26 27 EXPLODED VIEW...

Page 7: ...x 3 Lg 3 U30 528SS U30 528SS U30 528SS 13 Diffuser Ring OH SG 1 L21 1 L21 1 L21 1 14 Pipe Plug 1 2 NPT 1 U78 59ZPS U78 59ZPS U78 59ZPS 15 Pressure Gauge 1 U239 8 U239 8 U239 8 16 Pump Body 1 L76 36 L...

Page 8: ...2 5 2B Diaphragm Assembly Incl 2C 2D 2E 2F 2G 1 J120 16 2C Stem 1 J62 9 2D Diaphragm 1 J20 16 2E Spring Follower 1 J43 31 2F Ext Tooth Washer 1 U43 23ZP 2G Nut Hex Head 1 4 20 1 U36 36ZP 3 Spring 1 J2...

Reviews: