USER HANDBOOK 1.0 | DC2115, ET2115
Berghof Automation GmbH | Harretstrasse 1 | 72800 Eningen | www.berghof.com
21-0099-82-00-00-003 | 270010900_Anwenderhandbuch_DC-ET2115_EN.docx
50
6.3. Operation
6.3.1. Status displays
The status display function is dependent on the software development environment used in conjunction with
the device.
The operating status LEDs show the current status of the power supply, the module mode and any error mes-
sages.
Location of the operating status LEDs
The Run/Stop and Error LEDs display the system status.
Fig. 37: Location of the operating status LEDs
LED
Meaning
1
PWR (green)
Shows that the power supply to the electronics is correct.
2
Run/Stop
(yel-
low/green/red)
Shows the system statuses.
3
Error (red)
Shows the device has been stopped due to an error.
Meaning of the LED displays
System statuses are shown using flashing signals on the Run/Stop LED in yellow.
While the Run/Stop light is flashing yellow: The device is in use and must not be switched off.
The device does not show warnings via the LEDs during start-up.