LED status
ALARM
description
Status
CIRCULATOR
Possible
SOLUTION
Red LED on +
1 yellow LED
on (LED 5)
The drive shaft
is jammed
Start attempt
every 1.5
seconds
Wait or unjam
the drive shaft
Red LED on +
1 yellow LED
on (LED 4)
Low input
voltage
Warning only.
The circulator
continues to
operate
Check the
input voltage
Red LED on +
1 yellow LED
on (LED 3)
Electrical power
supply fault or
faulty circulator
The circulator
is stopped
Check the
electrical
power supply
or replace the
circulator
b
If there are several alarms the circulator will display only the
alarm with the highest priority.
Display of active settings
With the circulator powered, press briefly on the button (
A
) to view
the active configuration of the circulator. The LEDs indicate the active
settings.
In this phase no variations can be made to the circulator configura-
tion. Two seconds after the button (
A
) has been pressed the user
interface returns to the normal operating status display.
Key lock function
The purpose of the key lock function is to prevent accidental modifi-
cations to the settings or the improper use of the circulator.
When the key lock function is activated, long-pressing the button (
A
)
is prevented. This prevents the user from entering the circulator's
operating modes setting section.
Enabling/disabling the key lock function is achieved by pressing the
button (
A
) for more than 10 seconds. During this step all of the LEDs
(
C
) will flash for 1 second.
Changing the operating mode
In normal operating conditions the circulator works with the factory
settings or the last settings carried out.
To change the configuration:
Ensure that the key lock function is deactivated.
Press the button (
A
) for more than 2 seconds until the LEDs begin
to flash. Short-press the button (
A
) within 10 seconds and the user
interface will move on to display the next settings. The various avail-
able settings will appear in a cyclic sequence.
If the button (
A
) is not pressed, the last setting will be stored.
A
B
C
A. Operating status display
B. Settings display
C. Settings
Configuración
Iif the button (
A
) is pressed you can move back to the “active settings
display” again and check that the LEDs (
B
) and (
C
) indicate (for 2
seconds) the last setting carried out.
If the button (
A
) is not pressed for more than 2 seconds the user
interfaces switches to the “Operating status display”.
The available settings are shown in figure along with the related rep-
resentation of LED (
B
) and (
C
).
(*)
LED 1
R
LED 2
G
LED 3
G
LED 4
G
LED 5
G
(*) Factory set value
R red
G yellow
IMPORTANT
If the 3 (5 metres) or 4 (4 metres) curves are set the bypass must
be replaced with the one supplied, following the procedure indicated
below:
Remove boiler electrical power by setting the system's main switch
to off.
Close the system taps and empty the boiler heating circuit.
Extract the bypass body cover fixing spring (
D
).
Extract the bypass body cover (
E
).
Replace the bypass valve (
F
) with the one included.
Refit the bypass body cover and its spring.
D
F
E
Eventual releasing of the circulator shaft
-
I
nsert a screwdriver in the hole (
1
) of the circulator
- Press (
a
) and turn the screwdriver (
b
) until the release of the crank-
shaft.
b
Perform this operation with extreme caution to avoid damaging
the components.