Mynute Green E C.S.I.
15
The performance, indicated by the LEDs (B) and (C) is always visible
during normal operation of the circulator whereas the settings can be
carried out by pressing the button (A) (fig. 49).
Operating status indication
When the circulator is in operation the LED (B) is green (fig. 49). The
four yellow LEDs (C) indicate the electrical energy consumption (P1)
as shown in the following table
LED status
CIRCULATOR status
Consumption in
% of MAX P1 (*)
Green LED on +
1 yellow LED on
Operating at minimum
0~25
Green LED on +
2 yellow LEDs on
Operating at
minimum-medium
25~50
Green LED on +
3 yellow LEDs on
Operating at medium-
maximum
50~75
Green LED on +
4 yellow LEDs on
Operating at maximum
100
(*) For the power (P1) absorbed by the circulator see the indications
in the “Technical Data” table.
Alarm status indication
If the circulator has detected one or more alarms the two-coloured
LED (B) will be red (fig. 49). The four yellow LEDs (C) indicate the
type of alarm as shown in the following table.
LED status
ALARM
description
Status
CIRCULATOR
Possible
SOLUTION
Red LED on +
1 yellow LED
on (LED 5)
The drive shaft
is jammed
Start attempt
every 1.5
seconds
Wait or unjam
the drive shaft
Red LED on +
1 yellow LED
on (LED 4)
Low input
voltage
Warning only.
The circulator
continues to
operate
Check the
input voltage
Red LED on +
1 yellow LED
on (LED 3)
Electrical power
supply fault or
faulty circulator
The circulator
is stopped
Check the
electrical
power supply
or replace the
circulator
If there are several alarms the circulator will display only the
alarm with the highest priority.
Display of active settings
With the circulator powered, press briefly on the button (A) to view
the active configuration of the circulator (fig. 49). The LEDs indicate
the active settings.
In this phase no variations can be made to the circulator configura-
tion. Two seconds after the button (A) has been pressed the user
interface returns to the normal operating status display.
0
100
200
300
400
500
600
700
800
900
1000
1100
1200
1300
0
50
100
150
200
250
300
350
400
450
500
550
600
Modulation area
Discharge head [mbar]
6 METRES DISCHARGE HEAD
System capacity [l/h]
0
100
200
300
400
500
600
700
800
900
1000
1100
1200
1300
1400
0
100
50
150
200
250
300
350
400
450
500
550
600
650
Modulation area
Discharge head [mbar]
7 METRES DISCHARGE HEAD
System capacity [l/h]
0
100
200
300
400
500
600
700
800
900
1000
1100
1200
0
50
100
150
200
250
300
350
400
450
500
Modulation area
Discharge head [mbar]
5 METRES DISCHARGE HEAD
System capacity [l/h]
0
100
200
300
400
500
600
700
800
900
1000
1100
0
50
100
150
200
250
300
350
400
4 METRES DISCHARGE HEAD
Modulation area
System capacity [l/h]
Discharge head [mbar]