22
EXCLUSIVE GREEN HE C.S.I. - R.S.I.
PROGRAMMABLE PARAMETERS EXCLUSIVE GREEN HE R.S.I.
N.
PAR.
1
2
3
10
11
12
13
14
20
21
22
23
24
25
26
28
29
30
31
32
40
41
42
43
44
45
46
47
48
50
51
52
61
62
63
65
85
86
87
90
92
93
94
95
10-16-20-26-30-34-50-70
DEFAULT
(1)
1
26 (25kW)-34 (35kW)
5
3
60
60
80
5
1
80
20
MAX
MIN
6
6
15
5
0
45
25
1
1
1
1
1
20
1
10
-
1
0
0
4
6
6
20
0
0.6
-
41
0
5
0
0
PARAMETERS
(2)
0
- OFF
1 - ON
2 - Zone remote control panel
3 - CONNECT AP
4 - Not used
5 - Not used
6 - CONNECT AT/BT
7 - REMOTE CONNECT AT/BT
8 - REMOTE CONTROL- ZONE VALVES
*
The value is expressed on the display in revs/min/100 (example 3.600 = 36).
Some default values could be different from the one in the table, dependent on the status of data sheet updating
(1) Setted in factory
(2) Setted by technical assistance
0 - OFF
1 - Instantaneous
2 - Mini-tank
3 - External water- tank with thermostat
4 - External water- tank with sensor
5 - DS integrated water tank
6 3S integrated water tank
G20 G31
25 kW
60 60
35 kW
60 59
G20 G31
25 kW
12 19
35 kW
12 19
UNIT OF
MEASURE
min
°C
°C
°C
revs/min
revs/min
°C
°C
min
min
-
°C
°C
-
-
-
-
°C
°C
bar
PARAMETERS DESCRIPTION
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
MINOR PARAMETER
INSULATION LEVEL OF BUILDING
DHW MODE
DHW CIRCUIT MAXIMUM SET-POINT
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
HEATING MODE
HEATING CIRCUIT MAXIMUM SET-POINT
MINIMUM HEATING SET POINT
MAXIMUM HEATING VENTILATOR SPEED
MINIMUM HEATING VENTILATOR SPEED
DIFFERENTIAL HEATING POSITIVE
DIFFERENTIAL HEATING NEGATIVE
MAX HEATING POWER REDUCTION TIMER
FORCED HEATING SHUT DOWN TIMER
HEATING TIMER RESET FUNCTION
MAXIMUM HEATING SET POINT 2CH (II circuit)
MINIMUM HEATING SET POINT 2CH (II circuit)
DHW THERMOSTAT OPERATING MODE
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
S.A.R.A. FUNCTION
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
THERMOREGULATION FUNCTION
INCLINATION THERMOREGULATION CURVE (OTC)
THERMOREGULATION FUNCTION 2CH
INCLINATION THERMOREGULATION CURVE (OTC) 2CH
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
HEAT REQUEST TYPE CH1 (I circuit)
HEAT REQUEST TYPE CH2 (II circuit)
DHW ANTIFREEZE FUNCTION TEMPERATURE (ON)
HEATING ANTIFREEZE FUNC. DELIVERY TEMP. (ON)
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
EXTERNAL SENSOR REACTIVITY
SEMI-AUTOMATIC FILLING
AUTOMATIC FILLING PRESSURE (ON)
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
ADJUSTABLE SPEED PUMP
ENABLE POST-CIRCULATION FROM DHW TO HEATING
DURATION OF POST-CIRCULATION FROM DHW TO HEATING
PUMP IN CONTINUAL MODE CH1 (CIRCUIT 1)
PUMP IN CONTINUAL MODE CH2 (CIRCUIT 2)
MAX
20
60
80
39
10
10
20
20
1 (YES)
80
39
40
40
1
1
10
10
255 (very slow)
1.0
100
1
255
1
1
MIN
5
40
40
20
2
2
0
0
0 (NO)
40
20
0 - OFF
1 - AUTO
2 - ON
0 - OFF
1 - AUTO
0 - OFF
1 - AUTO
2,5
0 - OFF
1 - AUTO
2,5
0
0
0
0
0 (very fast)
0 - Disabled
1 - Enabled
0.4
0
0
1
0
0