Beretta EXCLUSIVE GREEN HE C.S.I. Installer And User Manual Download Page 1

 

 

EXCLUSIVE 

GREEN HE

C.S.I. - R.S.I.

EN

INSTALLER AND USER MANUAL

HU

TELEPÍTŐI ÉS FELHASZNÁLÓI KÉZIKÖNYV

RO

MANUAL DE INSTALARE SI UTILIZARE

  

SI

NAVODILA ZA VGRADITEV, PRIKLJUČITEV IN UPORABO

PL

INSTRUKCJA OBSŁUGI I INSTALACJI KOTŁA GAZOWEGO

ES

MANUAL DEL INSTALADOR Y DEL USUARIO

PT

MANUAL DO USUÁRIO E DO INSTALADOR

Summary of Contents for EXCLUSIVE GREEN HE C.S.I.

Page 1: ...ANUAL HU TELEP T I S FELHASZN L I K ZIK NYV RO MANUAL DE INSTALARE SI UTILIZARE SI NAVODILA ZA VGRADITEV PRIKLJU ITEV IN UPORABO PL INSTRUKCJA OBS UGI I INSTALACJI KOT A GAZOWEGO ES MANUAL DEL INSTALA...

Page 2: ...oiler operating elements 172 Hydraulic circuit 173 174 Electric diagrams 175 176 PT Installer s user s manual 52 Boiler operating elements 172 Hydraulic circuit 173 174 Electric diagrams 175 176 HU Te...

Page 3: ...o para instaladores En concreto Los cap tulos titulados Instalaci n de la caldera Conexiones hidr ulicas Conexi n del gas Conexi n el ctrica Rellenado y drenaje Evacuaci n de los productos de combusti...

Page 4: ...relative instructions do not pull detach or twist the wires from the boiler even if they are not connected to the power supply EN ENGLISH do not block or reduce the size of the ventilation openings in...

Page 5: ...med at maintaining the T between upstream and downstream of the heat exchanger at 10 C By periodically sampling the values provided by the boiler delivery return sensors the board increases or decreas...

Page 6: ...e been made airtight conforming to standard installation practices 7 ELECTRIC CONNECTION To access the electrical connections proceed as follows unscrew the lower cover fixing screw C Fig 1 4 pull the...

Page 7: ...upplied with the boiler must be connected to the valve to let out the water into an outside container 2 Open the manual system filling stopcock on the water group wait until the water starts coming ou...

Page 8: ...h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h W V Hz IP bar bar C mbar l h l bar bar bar l min l min l min l min C l min mbar mbar mm mm mm kg Pa Nm3 h N...

Page 9: ...Minimum number of fan revolutions MJ m3S MJ m3S MJ kgS mbar mm H2O mbar mm H2O n mm Sm3 h kg h Sm3 h kg h Sm3 h kg h Sm3 h kg h revs min revs min revs min n mm Sm3 h kg h Sm3 h kg h Sm3 h kg h Sm3 h k...

Page 10: ...s The display indicates SF and the function selection indicators light up in sequence Press button to interrupt the automatic vent cycle The display will look like Fig 2 If the test is unsuccessful th...

Page 11: ...and the display returns to the delivery temperature read by the probe Working the boiler Adjust the ambient thermostat to the required temperature approx 20 C If there is a demand for heating water t...

Page 12: ...s the circulator and the burner work at minimum power to increase the water temperature to a safe value 35 C The symbol lights up on the display circulator anti block one operating cycle is performed...

Page 13: ...ut 2 minutes the wording SF will appear on the display Fig 16 and the function selection indicators will light up in sequence Press button to stop the automatic vent cycle If you have to fill the syst...

Page 14: ...ensor Fig 21 Info 5 displays the set heating temperature in reference to the second circuit only if it is connected S A R A function Fig 21 If the winter mode is selected the S A R A Automatic Ambient...

Page 15: ...rough the slots in the cover located in the lower part of the boiler open the gas tap by turning it anti clockwise Fig 1 power the boiler When powered the boiler performs a test sequence and a series...

Page 16: ...16 EXCLUSIVE GREEN HE C S I R S I Open position 1 3 4 5 6 A 4 5 C 3 C 2 C 1 C 0 C 1 C 2 C 3 C 4 5 C 7 9 D 11 10 8 2...

Page 17: ...with thermostat in this condition every time there is a request from the water tank thermostat the boiler supplies hot water to preparing domestic hot water During this operation on the display the i...

Page 18: ...O appears Fig 17 Press the button to view operating information Press the button again to move on to the next piece of information If the button is not pressed the system automatically exits the funct...

Page 19: ...ault code is only displayed in standby R S I Only with external water tank with sensor The fault code is shown when the boiler is in stand by If these two errors occur check the pressure indicated on...

Page 20: ...arameter programming function is located on the back side of the control panel Confirm by pressing ENTER Modifying parameters Turn the domestic hot water temperature selector Fig G to sequentially scr...

Page 21: ...it HEAT REQUEST TYPE CH2 II circuit DHW ANTIFREEZE FUNCTION TEMPERATURE ON HEATING ANTIFREEZE FUNC DELIVERY TEMP ON THIS PARAMETER IS NOT USED ON THIS MODEL DO NOT MODIFY EXTERNAL SENSOR REACTIVITY SE...

Page 22: ...HIS MODEL DO NOT MODIFY HEATING MODE HEATING CIRCUIT MAXIMUM SET POINT MINIMUM HEATING SET POINT MAXIMUM HEATING VENTILATOR SPEED MINIMUM HEATING VENTILATOR SPEED DIFFERENTIAL HEATING POSITIVE DIFFERE...

Page 23: ...delivery temperature but affect the calculation made to automatically determine its value by modifying the reference temperature of the system 0 20 C For boilers fitted with the S A R A Function if th...

Page 24: ...on of thermoregulation curve 2CH OTC only if external sensor is connected HP maximum fan speed do not modify this parameter LP minimum fan speed do not modify this parameter SP ignition speed do not m...

Page 25: ...to the required position close the panel put back the shell 19 GAS CONVERSION It is easy to transform gas from one family to gas belonging to another family even with the boiler installed This job mus...

Page 26: ...d personnel from the Servicing Centre every year Check and compare the boiler s performance with the relative specifications Any cause of visible deterioration must be imme diately identified and elim...

Page 27: ...30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Heat capacity curve fan rpm Qnrisc 35 HE 1000 1500 2000 2500 3000 3500 4000 4500 500...

Page 28: ...te las aperturas de ventilaci n del local de instalaci n ES ESPA OL no dejar contenedores y sustancias inflamables en el local donde est instalado el aparato no dejar los elementos del embalaje al alc...

Page 29: ...los sensores de entrega retorno de la caldera el panel de control aumenta o disminuye la velocidad de la unidad de circulaci n y por tanto el caudal de la instalaci n Si el muestreo indica un valor d...

Page 30: ...heladas la instalaci n sanitaria ha de ser vaciada procediendo del siguiente modo cerrar el grifo general de la red h drica abrir todos los grifos del agua caliente y fr a vaciar los puntos m s bajos...

Page 31: ...var la solicitud de agua caliente de esta manera s lo en el caso de calderas instant neas durante 30 cada minuto para permitir que la tres v as se cambie de la funci n de calefacci n a la de agua sani...

Page 32: ...or la introducci n de una curva 90 45 Orificio di metro 10 DATOS T CNICOS C S I 25 kW C S I 35 kW R S I 25 kW R S I 35 kW kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal...

Page 33: ...lador MJ m3S MJ m3S MJ kgS mbar mm H2O mbar mm H2O n mm Sm3 h kg h Sm3 h kg h Sm3 h kg h Sm3 h kg h r min r min r min n mm Sm3 h kg h Sm3 h kg h Sm3 h kg h Sm3 h kg h r min r min r min n mm Sm3 h kg h...

Page 34: ...nteo con una duraci n de unos 2 minutos en el visualizador se muestra el mensaje SF y se iluminan en secuencia los Indicadores de selecci n de la funci n Pulsar la tecla para interrumpir el ciclo de v...

Page 35: ...caldera seguir funcionando hasta que se alcancen las temperaturas programadas luego se pondr en stand by En caso de que se produzcan anomal as de encendido o funcionamiento la caldera efectuar una par...

Page 36: ...gital visualizar en la zona central dos segmentos Posicionar el interruptor general de la instalaci n en apagado Luego cerrar la llave del gas situado debajo de la caldera girando en el sentido de las...

Page 37: ...lo SF aparecer en la pantalla Fig 16 y los indicadores de selecci n de funci n se iluminar n en secuencia Apretar el bot n para interrumpir el ciclo de venteo autom tico Teniendo que repetir varias ve...

Page 38: ...isualiza la temperatura programada del segundo circuito de cale facci n solo en caso de conexi n del mismo Funci n S A R A Fig 21 Si se selecciona la posici n invierno es posible activar la funci n S...

Page 39: ...a la llave del gas a trav s de las ranuras de la tapa cubre conexiones situada en la parte inferior de la caldera abrir la llave girando en el sentido inverso a las agujas del reloj para permitir el...

Page 40: ...40 EXCLUSIVE GREEN HE C S I R S I Posici n abierta 1 3 4 5 6 A 4 5 C 3 C 2 C 1 C 0 C 1 C 2 C 3 C 4 5 C 7 9 D 11 10 8 2...

Page 41: ...agujas del reloj la temperatura aumenta en el sentido inverso disminuye Los segmentos de la barra grafica se iluminan cada 3 C en cuanto la temperatura aumenta Una vez seleccionada despu s de unos 4 s...

Page 42: ...erior ejemplo 12 C Fig 18 Los valores mostrados en la pantalla van de los 30 C a los 35 C M s all de estos valores la pantalla muestra Info 2 visualiza la presi n de llenado instalaci n Fig 19 Info 3...

Page 43: ...res verificar la presi n indicada por el hidr metro Si la presi n es insuficiente 0 4 bar campo rojo proceder con las operaciones de llenado descritas en el cap tulo Llenado y vaciado instalaci n Si l...

Page 44: ...ar metros est posicionada en el interior del panel de mando Confirmar la entrada pulsando la tecla ENTER Modificaci n de los par metros Girando el selector temperatura agua sanitario Fig G pasan en se...

Page 45: ...TIPO PETICI N CALOR 1ER CIRCUITO CALEFACCI N TIPO PETICI N CALOR 2 CIRCUITO CALEFACCI N TEMPER FUNCI N ANTIHIELO SANITARIO ON TEMPER FUNCI N ANTIHIELO CALEFACCI N ON PAR METRO NO UTILIZABLE EN ESTE MO...

Page 46: ...IFICAR ACTIVACI N FUNCI N TERMORREGULACI N INCLINACI N CURVA DE TERMORREGUL OTC FUNCI N TERMORREGULACI N 2 CIRCUITO INCLINACI N CURVA DE TERMORREGUL OTC 2 CIRCUITO PAR METRO NO UTILIZABLE EN ESTE MODE...

Page 47: ...este valor no modifica directamente la temperatura de impulsi n sino que act a en el c lculo que determina el valor de modo autom tico variando en el sistema la temperatura de referencia 0 20 C En la...

Page 48: ...agua sanitario pasan en secuencia las fases del REGULACI N MANTENIMIENTO 1 tipo de gas no modificar este par metro 2 potencia de la caldera par metro menor 3 grado de aislamiento del edificio solo si...

Page 49: ...a cerrar el panel volver a colocar la cubierta 19 CONVERSI N DE GAS Es f cil transformar gas de una familia en un gas de otra familia incluso con la caldera instalada Este trabajo debe ser llevado a c...

Page 50: ...s sistem ticos y a intervalos regulares La frecuencia de los controles depende de las condiciones de in stalaci n y de uso Si fuera necesario realizar un control anual com pleto solicitar la intervenc...

Page 51: ...0 70 80 90 100 110 120 130 140 150 160 170 180 190 200 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Curva de capacidad de calefacci n ventilador rpm Qnrisc 35 HE 1000 1500 2000 2500 3000 3500 400...

Page 52: ...autorizado ou sem as indica es do fabricante PT PORTUG ES n o puxe arranque ou tor a os cabos el ctricos que sa rem da caldeira embora esta esteja desligada da rede da alimenta o el ctrica preciso evi...

Page 53: ...pelos sensores caudal de retorno da caldeira faz a placa aumentar ou diminuir a velocidade da unidade de circula o e portanto a taxa de fluxo da planta Se a amostragem mostrar um valor de T abaixo do...

Page 54: ...nstala o 3 CONEX ES HIDR ULICAS A posi o e a dimens o dos acoplamentos hidr ulicos s o indicadas na figura 1 1 A retorno aquecimento 3 4 B sa da aquecimento 3 4 C conex o g s 3 4 D sa da circuito sani...

Page 55: ...orma que a v lvula de tr s vias se posicione na modalidade aquecimento 5 Active uma procura de gua sanit ria caldeiras instant neas abrindo a torneira por 30 a intervalos de 1 minuto para que a v lvul...

Page 56: ...atravessamento parede di metro Di metro Comprimento m ximo Perda por inser o de uma curva 90 45 Furo de atravessamento parede di metro kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kc...

Page 57: ...essivo M ximo n mero de rota es ventilador M nimo n mero de rota es do ventilador MJ m3S MJ m3S MJ kgS mbar mm H2O mbar mm H2O n mm Sm3 h kg h Sm3 h kg h Sm3 h kg h Sm3 h kg h C C C n mm Sm3 h kg h Sm...

Page 58: ...o g s atrav s das fendas da cobertura das conex es posta na parte inferior da caldeira abrir a torneira virando o man pulo no sentido dos ponteiros do rel gio para consentir o fluxo do combust vel Fig...

Page 59: ...sanit ria Para regular a temperatura da gua do circuito sanit rio vire o seleccionar D Fig 9 no sentido dos ponteiros do rel gio a temperatura aumenta ao contr rio diminui Os segmentos da barra gr fi...

Page 60: ...a levarem novamente a temperatura da gua a valores de seguran a 35 C No display ilumina se o s mbolo anti bloqueio da bomba circuladora um ciclo de funcionamento activa se a intervalos de 24 h Apagame...

Page 61: ...ouro autom tico que durar cerca de 2 minutos o c digo SF aparecer no ecr Fig 16 e os indicadores de selec o de fun o se iluminar o em sequ ncia Carregue no bot o para parar o ciclo de respiradouro aut...

Page 62: ...a de aquecimento ajustada que se refere ao segundo circuito s no caso do mesmo estiver conectado Fun o S A R A Fig 21 Se o modo inverno est seleccionado a fun o S A R A Sistema de ajuste de ambiente a...

Page 63: ...o aparelho preciso chegar torneira do g s atrav s das fendas da cobertura das conex es posta na parte inferior da caldeira abrir a torneira virando o man pulo no sentido dos ponteiros do rel gio para...

Page 64: ...64 EXCLUSIVE GREEN HE C S I R S I Posi o aberta 1 3 4 5 6 A 4 5 C 3 C 2 C 1 C 0 C 1 C 2 C 3 C 4 5 C 7 9 D 11 10 8 2...

Page 65: ...nda para regular a temperatura da gua sanit ria armazenada no boiler vire o seleccionador de temperatura D Fig 9 no sentido dos ponteiros do rel gio a temperatura aumenta ao contr rio diminui Os segme...

Page 66: ...automaticamente da fun o Lista Info Info 0 visualiza a inscri o InFO Fig 17 Info 1 com a sonda externa ligada visualiza a temperatura externa ex 12 C Fig 18 Os valores mostrados no ecr variam entre 30...

Page 67: ...caldeira em stand by Caso se apresentem estes dois erros verifique a press o indicada pelo hidr metro Se a press o for insuficiente 0 4 bar campo vermelho proceda s opera es de enchimento descritas n...

Page 68: ...do painel de comando Confirme a entrada carregando na tecla ENTER Modifica o dos par metros Virando o seleccionador da temperatura da gua do circuito sanit rio Fig G percorrem se em sequ ncia os c dig...

Page 69: ...AJUSTE PARA ZERO TIMER AQUECIMENTO M SSIMO SET POINT AQUECIMENTO 2CH II circuito M NIMO SET POINT AQUECIMENTO 2CH II circuito TIPO FUNCIONAMENTO TERM ST CIRC SANIT RIO PAR METRO N O UTILIZ VEL NESTE...

Page 70: ...TO FUN O AJUSTE PARA ZERO TIMER AQUECIMENTO M SSIMO SET POINT AQUECIMENTO 2CH II circuito M NIMO SET POINT AQUECIMENTO 2CH II circuito TIPO FUNCIONAMENTO TERM ST CIRC SANIT RIO PAR METRO N O UTILIZ VE...

Page 71: ...neste valor modifica directamente a temperatura de sa da mas age sobre o c clulo que determina automaticamente o seu valor variando no sistema a temperatura de refer ncia 0 20 C Se nas s onde estiver...

Page 72: ...to sanit rio percorrem se em sequ ncia as fases da CALIBRA O SERVICE 1 tipo de g s este par metro n o deve ser modificado 2 pot ncia da caldeira par metro menor 3 grau de isolamento do edif cio visual...

Page 73: ...necess ria feche o painel recoloque a tampa 19 TRANSFORMA O DO G S A transforma o de um g s de uma fam lia para um g s de outra fam lia pode se efectuar facilmente at depois de se ter instalado a cald...

Page 74: ...odica mente o equipamento a controlos sistem ticos A frequ ncia dos controlos depende das condi es de instala o e utiliza o embora seja necess rio mandar efectuar anualmente um controlo completo pelo...

Page 75: ...70 80 90 100 110 120 130 140 150 160 170 180 190 200 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Curva de capacidade de calor rpm do ventilador Qnrisc 35 HE 1000 1500 2000 2500 3000 3500 4000 4...

Page 76: ...a k beleket a kaz nb l akkor sem ha ramtalan tva van HU HUNGARIAN tilos eldugaszolni vagy lesz k teni a szell z ny l sokat abban a helyis gben ahol a k sz l k zemel ne hagyjon gy l kony anyagot s tar...

Page 77: ...g l tatott rt keket a kapcsol t bla megn veli vagy lecs kkenti a keringet egys g sebess g t ez ltal pedig a berendez s hozam t Ha a m rt adatok a megadott T rt kn l alacsonyabbat mutatnak a sebess ge...

Page 78: ...kez m don z rja el a v zrendszer f csapj t nyissa meg az sszes hideg s melegv zcsapot v ztelen tse a rendszer legals pontjait 3 V ZBEK T S A v zcsatlakoz sok elhelyezked s t s m ret t az 1 1 bra szeml...

Page 79: ...h rom ll s a f t st l a meleg v zig s vissza kb 10 szer lemenjen ekkor a kaz n v szjelz sbe fog llni mivel nincs g z s rezetelnie kell minden alkalommal amikor ez t rt nik Csak f t kaz nok k ls v zt...

Page 80: ...r Max hossz s g Vesztes g 90 45 kanyarulat beiktat sa miatt kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h W V Hz IP bar bar C...

Page 81: ...tsz ma MJ m3S MJ m3S MJ kgS mbar mm H2O mbar mm H2O n mm Sm3 h kg h Sm3 h kg h Sm3 h kg h Sm3 h kg h ford perc ford perc ford perc n mm Sm3 h kg h Sm3 h kg h Sm3 h kg h Sm3 h kg h ford perc ford perc...

Page 82: ...n ekkor a 2 bra szerinti ikonok jelennek meg Amennyiben a k sz l k az ellen rz s sor n hib t szlel a kaz n nem fog dol gozni a kijelz n a 0 jelz s villog Ez esetben k rj k forduljon a szakszervizhez...

Page 83: ...vel a k sz l k elt rolja a v ltoztat st s a megjelen tett rt k ism t az rz kel ltal m rt val s h m rs kletet jelzi A kaz n beind t sa ll tsa be a szobatermoszt ton a k v nt h m rs kletet kb 20 C Amen...

Page 84: ...z g minim lis teljes tm nyen m k dik mindaddig m g a v z h m rs klete el nem ri ism t a biztons gi rt ket 35 C Ekkor a kijelz n megjelenik a kijelz s keringet szivatty blokkol sg tl kikapcsol s eset n...

Page 85: ...a k perny n 16 bra s a m k d st kiv laszt jelz villog Nyomja meg a gombot hogy le lljon az automatikus l gtelen t ciklus Amennyiben a felt lt si m veletet t bbsz r egym s ut n meg kell ism telni ta n...

Page 86: ...jelen ti meg only water tank with sensor Fig 21 Info 5 a m sodik f t k rre be ll tott f t si h m rs kletet jelen ti meg kiz r lag akkor ha csatlakozik ilyen a k sz l khez S A R A funkci 21 bra Amenny...

Page 87: ...bi m veleteket kell elv gezni hogy hozz f rjen a g zcsaphoz haszn lja a kaz n alatt tal lhat burkolat ny l sait nyissa ki a g zcsapot az ramutat j r s val ellent tes ir nyba elford tva 1 bra Kapcsolja...

Page 88: ...88 EXCLUSIVE GREEN HE C S I R S I Nyitott ll s 1 3 4 5 6 A 4 5 C 3 C 2 C 1 C 0 C 1 C 2 C 3 C 4 5 C 7 9 D 11 10 8 2...

Page 89: ...si funkci v zt rol szenzorral h zi melegv z h m rs k let nek be ll t s hoz ami a v zt rol ban van ford tsa el a D kapcsol t 9 bra ha az ramutat j r s val megegyez ir nyba ford tja a kapcsol t a h m rs...

Page 90: ...r lag csatlakoztatott k ls rz kel eset n a kijelz n a k ls h m r s klet rt ke jelenik meg pl 12 C 18 bra A kijelz ltal megjelen tett h m rs klettartom ny 30 C s 35 C k z tt mozog Ezen tartom nyon k v...

Page 91: ...llapotban jelenik meg R S I Csak rz kel vel ell tott k ls v zt rol val A hibak d csak stand by llapotban jelenik meg Amennyiben ez a k t hiba jelentkezne ellen rizze a nyom sm r ltal jelzett nyom st A...

Page 92: ...TER gomb megnyom s val er s tse meg bel p si sz nd k t Param terek m dos t sa A HMV h m rs kletszab lyoz gomb G bra elford t s val a t bl zatban ta l lhat k tjegy param terk dok jelennek meg Miut n ki...

Page 93: ...LN L NEM HASZN LHAT NE M DOS TSON A PROGRAMOZ SON LL THAT SZIVATTY SEBESS G LEHET V TESZI AZ UT KERINGET ST A HMV T L A F T SIG UT KERINGET S TARTALMA A HMV T L A F T SIG SZIVATTY FOLYAMATOS ZEMM DBAN...

Page 94: ...NY T PUSA CH1 I f t k r H IG NY T PUSA CH2 II f t k r HMV FAGY LL FUNKCI H M ON F T K RI FAGY LL FUNKC EL REMEN H M RS KLET ON ENN L A MODELLN L NEM HASZN LHAT NE M DOS TSONAPROGRAMOZ SON K LS RZ KEL...

Page 95: ...v ltoztatja meg hanem ennek az automatikus kisz mol s t befoly solja a viszony t si h m rs klet m dos t s val 0 20 C A S A R A funkci val ell tott kaz nokn l ha a BELT RI H SZAB LYOZ t l sok ig le va...

Page 96: ...ne v ltoztasson ezen a param teren 45 h szab lyoz si g rbe d l ssz ge OTC kiz r lag k ls rz kel haszn lata eset n jelen thet meg 47 h szab lyoz si g rbe d l ssz ge 2CH OTC kiz r lag k ls rz kel haszn...

Page 97: ...k penyt s a m szerfalat a kaz nr l Emelje fel s forgassa el a m szerfalat Z rja vissza a leveg tart ly fedel t Csak 25 HE eset ben csavarjaki a hangtomp t t tart csavarokat A s vegye ki 1 18 bra Vegy...

Page 98: ...helyi f stg z kibocs t sra vonatkoz hat r rt kek H teljes tm ny g rbe ventil tor rpm Qnrisc 25 HE H teljes tm ny g rbe kibocs t sok Qnrisc 25 HE F t si h teljes tm ny kW F t si h teljes tm ny kW HTG...

Page 99: ...50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 H teljes tm ny g rbe ventil tor rpm Qnrisc 35 HE 1000 1500 2000 2500 3000 3500 4000 4500 5...

Page 100: ...elor de siguran sau de reglare f r permisiunea i instruc iunile corespunz toare ale produc torului nu trage i nu deta a i i nu r suci i cablurile de la central chiar dac acestea nu sunt conectate la s...

Page 101: ...torului de c ldur la 10 C Prin prelevarea periodic a valorilor furnizate de senzorii de tur retur ai centralei placa m re te sau reduce viteza unit ii de circulare i implicit debitul instala iei Dac...

Page 102: ...e golit ori de c te ori exist risc de nghe prin nchiderea robinetului de la sursa de alimentare deschiderea tuturor robinetelor de ap cald i rece golirea p r ilor inferioare ale instala iei 3 CONEXIUN...

Page 103: ...nda la distan pentru a activa cererea de c ldur astfel nc t vana cu trei c i s comute pe nc lzire 5 Activa i cererea de ap cald dup cum urmeaz centrale instant deschide i un robinet pentru 30 la fieca...

Page 104: ...l h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h W V Hz IP bari bari C mbari l h l bari bari bari l min l min l min l min C l min mbari mbari mm mm mm kg P...

Page 105: ...ta ii ventilator MJ m3 S MJ m3S MJ kgS mbari mm H2 O mbari mm H2 O n mm Sm3 h kg h Sm3 h kg h Sm3 h kg h Sm3 h kg h rot min rot min rot min n mm Sm3 h kg h Sm3 h kg h Sm3 h kg h Sm3 h kg h rot min rot...

Page 106: ...ntrala ncepe un ciclu automat de aeri sire care dureaz circa 2 minute Afi ajul indic SF i indicatorii de selec ie a func iei se aprind consecutiv Ap sa i pe butonul pentru a ntrerupe ciclul automat de...

Page 107: ...a este memorat i afi ajul revine la temperatura pe tur citit de sond Func ionarea centralei Regla i termostatul de ambient la temperatura necesar aprox 20 C Dac se solicit ap de nc lzire centrala porn...

Page 108: ...rul func ioneaz la putere minim pentru a m ri temperatura apei la o valoare sigur 35 C Simbolul se aprinde pe afi aj anti blocare pomp de circula ie se efectueaz un ciclu de func ionare la fiecare 24...

Page 109: ...a dura circa 2 minute pe afi aj vor ap rea literele SF Fig 16 iar indicatoarele de selec ie a func ion rii vor ilumina succesiv Ap sa i butonul pentru a opri ciclu automat de aerisire Dac trebuie s um...

Page 110: ...cu senzor Fig 21 Info 5 afi eaz temperatura setat a apei de nc lzire a circuitului secundar numai dac este conectat Func ia S A R A Fig 21 Dac este selectat modul iarn se poate activa func ia S A R A...

Page 111: ...a dup cum urmeaz accesa i robinetul de gaz prin fantele din capacul situat n partea inferioar a centralei deschide i robinetul de gaz prin rotire n sens antiorar Fig 1 pune i centrala sub tensiune C n...

Page 112: ...112 EXCLUSIVE GREEN HE C S I R S I Pozi ie deschis 1 3 4 5 6 A 4 5 C 3 C 2 C 1 C 0 C 1 C 2 C 3 C 4 5 C 7 9 D 11 10 8 2...

Page 113: ...aturii apei calde menajere stocate n boiler roti i comutatorul D Fig 9 n sens orar pentru cre tere i n sens antiorar pentru descre tere Segmentele barei se aprind la fiecare 3 C odat cu cre terea temp...

Page 114: ...tul InFO Fig 17 Info 1 numai cu senzor extern conectat afi eaz temperatura exterioar de ex 12 C Fig 18 Valorile afi ate pe ecran pot fi cuprinse ntre 30 C i 35 C n afara acestor valori afi ajul indic...

Page 115: ...I Numai cu boiler extern cu senzor Codul de defect este afi at c nd centrala se afl n a teptare Dac apar aceste dou erori verifica i presiunea indicat pe manometru Dac presiunea este insuficient 0 4...

Page 116: ...de programare a parametrilor este situat pe partea din spate a panoului de comand Confirma i ap s nd ENTER Modificarea parametrilor Roti i selectorul de temperatur a apei calde menajere Fig G pentru...

Page 117: ...E CIRCUIT 2 C SELEC IE CURB TERMOREGLARE OTC CIRCUIT 2 C ACEST PARAMETRU NU ESTE UTILIZAT N ACEST MODEL NU MODIFICA I ACEST PARAMETRU NU ESTE UTILIZAT N ACEST MODEL NU MODIFICA I DEPLASARE PARALEL C1...

Page 118: ...NU MODIFICA I DEPLASARE PARALEL C1 circuit I DEPLASARE PARALEL C2 circuit II TEMPERATUR FUNC IE ANTI NGHE ACM PORNIT TEMPERATUR FUNC IE ANTI NGHE NC LZIRE PORNIT ACEST PARAMETRU NU ESTE UTILIZAT N ACE...

Page 119: ...up necesit i Modific rile acestei valori nu afecteaz direct temperatura pe tur ci calculele efectuate pentru determinarea automat a valorii acesteia prin modificarea temperaturii de referin a sistemul...

Page 120: ...SERVICE 1 tip de gaz nu modifica i acest parametru 2 putere central parametru minor 3 nivel de izola ie a cl dirii numai dac este conectat un senzor exterior 10 mod ap cald menajer Exclusive Green HE...

Page 121: ...e aluminiu Utiliz nd cheia CH6 demonta i ARUNCA I I NU REFOLOSI I cele dou duze C cur a i resturile din plastic din l ca ul acestora Fig 1 20 Introduce i cele 2 duze noi din kit p n la nivelul p r ii...

Page 122: ...e emisiilor de gaze de ardere Curb capacitate termic tura ie ventilator Qnrisc 25 HE Curb capacitate termic emisii Qnrisc 25 HE Capacitate termic nc lzire kW Capacitate termic nc lzire kW Tura ie vent...

Page 123: ...0 80 90 100 110 120 130 140 150 160 170 180 190 200 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Curb capacitate termic tura ie ventilator Qnrisc 35 HE 1000 1500 2000 2500 3000 3500 4000 4500 500...

Page 124: ...m izklju ite elektri no napajanje prepovedano je spreminjanje in poseganje v varnostne sklope in naprave brez pooblastila in navodil proizvajalca SI SLOVEN INA ne vlecite lo ite ali sukajte elektri no...

Page 125: ...i in izstopni senzor kotla krmilje pove a ali zmanj a hitrost preto ne rpalke in s tem pretok v sistemu e vzor enje javi T vrednost manj o od nastavljene se hitrost zmanj a za toliko da se T zvi a na...

Page 126: ...e nevarno da bo zmrzovalo se mora napeljavo sanitarne vode tako izprazniti zaprite glavni ventil na dovodu vode odprite vse pipe hladne in tople vode izpraznite najni je dele napeljave 3 HIDRAVLI NA P...

Page 127: ...i vodo iz ventila lahko speljali v posodo zunaj kotla 2 Odprite pipo na dovodu vode iz vodovodnega omre ja in po akajte da iz ventila za izlo anje zraka za ne iztekati voda 3 Kotlu vklju ite elektri n...

Page 128: ...kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h kW kcal h W V Hz IP bar bar C mbar l h l bar bar bar l min l min l min l min C l min mbar...

Page 129: ...ajve je tevilo vrtljajev ventilatorja Najmanj e tevilo vrtljajev ventilatorja Vrednosti za sanitarno vodo se nana ajo na modele GREEN C S I Povpre na vrednost razli nih pogojev delovanja sanitarne vod...

Page 130: ...ja kotel pri ne izvajati avtomatski postopek izlo anja zraka ki traja pribli no 2 minuti Na zaslonu je prikazano SF in indikatorji na ina delovanja zasvetijo v zaporedju Pritisnite tipko za prekinitev...

Page 131: ...jenosti V primeru napake med v igom ali med delovanjem pa bo kotel opravil varnostno ustavitev V tem primeru bo simbol plamena na zaslonu ugasnil prikazana bo koda napake in in napis slika 11 Za opise...

Page 132: ...12b Zaprite pipo za plin ki se nahaja pod kotlom z zasukom v desno slika 12b V tem primeru sta sistema proti zmrzovanju in proti blokiranju rpalke izklju ena Izpraznite vodo iz sistema ali jo za itit...

Page 133: ...az SF slika 16 in indikatorji na ina delovanja se prikazujejo v zaporedju Pritisnite tipko za prekinitev avtomatskega postopka izlo anja zraka e je sistem potrebno ve krat polniti se obrnite na poobla...

Page 134: ...a 21 Info 5 prika e nastavitev temperature ogrevanja za drugo ogrevalno vejo e je priklju ena Funkcija S A R A slika 21 e je izbran na in zima se lahko aktivira funkcijo S A R A sistem za samodejno pr...

Page 135: ...u priklju kov v spodnjem delu kotla poi ite pipo za plin pipo za plin odprite z zasukom v levo slika 1 vklopite napajanje kotla Po vklju itvi elektri nega napajanja bo kotel opravil zaporedje samodejn...

Page 136: ...136 EXCLUSIVE GREEN HE C S I R S I Odprt polo aj 1 3 4 5 6 A 4 5 C 3 C 2 C 1 C 0 C 1 C 2 C 3 C 4 5 C 7 9 D 11 10 8 2...

Page 137: ...e tople sanitarne vode v vsebniku obrnite stikalo D slika 9 v desno za zvi anje in v levo za zni anje Vrstica s segmenti napreduje v stopnjah po 3 C sorazmerno z vi anjem temperature Pribli no 4 sekun...

Page 138: ...klju enim zunanjim tipalom prikazuje zunanjo temperaturo npr 12 C slika 18 Prika e lahko vrednosti v obmo ju med 30 C in 35 C Izven tega obmo ja prikazuje Info 2 prika e tlak v sistemu slika 19 Info 3...

Page 139: ...alne temperature tople sanitarne vode vendar jo vseeno dobavlja s temperaturo okrog 50 C Koda napake se izpi e le ko je kotel v stanju pripravljenosti R S I Samo z zunanjim vsebnikom sanitarne vode in...

Page 140: ...zadnji strani komandne plo e Potrdite s pritiskom na ENTER Spreminjanje parametrov Z vrtenjem gumba za nastavitev temperature sanitarne vode slika G se zaporedoma izpisujejo dvo tevil ne kode posamezn...

Page 141: ...TIP ZAHTEVE PO TOPLOTI CH1 I veja TIP ZAHTEVE PO TOPLOTI CH2 II veja TEMPERAT SANIT VODE ZA ZA ITO PROTI ZMRZOVANJU ON TEMPERAT OGREVANJA ZA ZA ITO PROTI ZMRZOVANJU ON TA PARAMETER SE S TEM MODELOM NE...

Page 142: ...REGULACIJE NAGIB KRIVULJE TERMOREGULACIJE OTC FUNKCIJA TERMOREGULACIJE 2 VEJE NAGIB KRIVULJE TERMOREGULACIJE OTC 2 VEJE TA PARAMETER SE S TEM MODELOM NE UPORABLJA NE SPREMINJAJTE TA PARAMETER SE S TEM...

Page 143: ...Sprememba te vrednosti ne vpliva neposredno na vrednost temperature v dvi ni vod ampak vpliva na izra unavanje temperature glede na izhodi no temperaturo vode v sistemu 0 20 C V kotlih z vklju eno fu...

Page 144: ...jajte 2 mo kotla parameter ne vpliva 3 stopnja izoliranosti stavbe samo s priklju enim zunanjim tipalom 10 priprava tople sanitarne vode Exclusive Green HE CSI ta parameter ne spreminjajte 45 nagib to...

Page 145: ...m nastavljanju nastavitev temperature s sobnim termostatom povrnite v eleni polo aj zaprite komandno plo o ponovno namestite pla 19 MENJAVA VRSTE PLINA Prehod z ene vrste plina na drugo vrsto je prepr...

Page 146: ...ogojev uporabe eprav morajo poobla eni strokovnjaki oddelka za tehni ni servis izvesti letni celotni pregled Preverite in primerjajte delovanje grelnika vode z ustreznimi specifi kacijami Vsi vzroki v...

Page 147: ...0 70 80 90 100 110 120 130 140 150 160 170 180 190 200 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Krivulja toplotne zmogljivosti t vrt ventilatorja Qnrisc 35 HE 1000 1500 2000 2500 3000 3500 40...

Page 148: ...podarstwa domowego itp je li czuje si w otoczeniu rozchodz cy si zapach gazu W takim przypadku nale y natychmiast wywietrzy pomieszczenie otwieraj c szeroko okna i drzwi zamkn g wny kurek gazu niezw o...

Page 149: ...ci ustawion przez instalatora Ten tryb dedykowany jest do instalacji wysokotemperaturowych gdzie kocio nie jest sterowany przez termostat pokojowy i gdzie obliczona T mo e by ustawiona Podczas pracy...

Page 150: ...y grupy hydraulicznej 9 Otworzy zaw r gazowy i uruchomi kocio 3 PO CZENIA HYDRAULICZNE Rozstaw oraz wymiary po cze hydraulicznych znajduj si na rys 1 1 A Powr t c o 3 4 B Zasilanie c o 3 4 C Pod czeni...

Page 151: ...spadek 1 przewod w wydalania spalin w kierunku kot a Model kot a Maksymalna d ugo przewodu 80 mm Strata na ka dym kolanie 45 90 m 25 C S I R S I 50m 1 1 5 35 C S I R S I 60m INSTALACJA TYPU C POB R P...

Page 152: ...1 105 2 106 1 Pob r mocy elektrycznej W 88 116 88 116 Kategoria II2H3P II2H3P II2H3P II2H3P Zasilanie V Hz 230 50 230 50 230 50 230 50 Stopie zabezpieczenia przeciwpora eniowego IP X5D X5D X5D X5D St...

Page 153: ...zu ycie gazu dla c w u Sm 3 h 2 64 kg h 1 94 Minimalne zu ycie gazu dla c o Sm 3 h 0 26 kg h 0 35 Minimalne zu ycie gazu dla c w u Sm 3 h 0 26 kg h 0 35 Ilo obrot w powolnego zap onu obr min 3 700 3...

Page 154: ...nego ogrzewania S upkowy wy wietlacz podzielony na segmenty kt ry jest stopniow skal temperatury w obwodzie centralnego ogrzewania symbol grzejnika S upkowy wy wietlacz podzielony na segmenty kt ry je...

Page 155: ...ci temperatury zostanie ona zapami tana i na wy wietlaczu pojawi si aktualne wskazanie temperatury odczytane przez sond Praca kot a Ustaw termostat rodowiskowy na oczekiwan warto temperatury w pomies...

Page 156: ...w czy si pompa oraz palnik z minimaln moc aby zwi kszy temperatur do bezpiecznej warto ci 35 C Symbol pojawi si na wy wietlaczu antyblokuj c pompy jeden cykl powtarza si co ka de 24 godziny Wy czenie...

Page 157: ...kocio i nast pnie naci nij przycisk aby rozpocz nape nianie instalacji Je li problem zostanie rozwi zany to kocio powinien przej w cykl automatycznego odpowietrzenia instalacji na oko o 2 minuty symb...

Page 158: ...d czona zamiast warto ci wy wietlone zostan dwa my lniki je li na wy wietlaczu pojawi si punkt temperatura spalin wynosi 100 wy wietlona warto je li przep yw jest wi kszy od 10l min C A x l min gdzie...

Page 159: ...zony zasobnik Przycisk Info pokazuje informacje na temat aktualnego stanu pracy kot a Uruchamianie kot a Czynno pierwszego uruchomienia musi by wykonana przez Autoryzowany Serwis Beretta W celu p niej...

Page 160: ...160 EXCLUSIVE GREEN HE C S I R S I 1 3 4 5 6 A 4 5 C 3 C 2 C 1 C 0 C 1 C 2 C 3 C 4 5 C 7 9 D 11 10 8 2 Zaw r w pozycji otwarty...

Page 161: ...em D rys 9 Obracaj c pokr t o w kierunku zgodnym do ruchu wskaz wek zegara zwi kszamy temperatur natomiast obracaj c pokr t o w kierunku przeciwnym zmniejszamy temperatur Na wy wietlaczu s upkowym zap...

Page 162: ...zob rozdzia Rozwi zywanie problem w Je li na wy wietlaczu widnieje kod b du 40 rys 16 nale y post powa nast puj co u y przycisku otworzy zaw r nape niania i pozostawi w tej pozycji do momentu pojawie...

Page 163: ...e ciep ej wody u ytkowej 60 kocio b dzie pracowa ale mo e nie utrzymywa sta ej temperatury kt rej warto b dzie na poziomie 50 C W takim przypadku na wy wietlaczu pojawi si tylko kod b du W przypadku w...

Page 164: ...przycisk oznaczony symbolem dzia a jak ESC wyj cie Je li w ci gu 10 sekund nowo wybrana warto nie zostanie potwierdzona w wczas zmiana nie zostanie zapami tana Warto parametru b dzie taka sama jak pr...

Page 165: ...TIMERA CO 0 NIE 1 TAK 0 31 MAX TEMP NA C O 2 OBIEG C 40 80 45 32 MIN TEMP NA C O 2 OBIEG C 20 39 25 40 FUNKCJA TERMOSTATU C W U 0 OFF 1 AUTO 2 ON 1 41 FUNKCJA PODGRZANIA WST PNEGO C W U 1 42 FUNKCJA S...

Page 166: ...30 FUNKCJA TIMERA CO 0 NIE 1 TAK 0 31 MAX TEMP NA C O 2 OBIEG C 40 80 45 32 MIN TEMP NA C O 2 OBIEG C 20 39 25 40 FUNKCJA TERMOSTATU C W U 0 OFF 1 AUTO 2 ON 1 41 FUNKCJA PODGRZANIA WST PNEGO C W U 1...

Page 167: ...rojektowej temperatury zewn trznej czyli od obszaru geograficznego oraz od doprowadzonej temperatury projektowej czyli od typu instalacji i jest obliczana z dok adno ci przez instalatora wed ug nast p...

Page 168: ...dy u ytkowej i ustawiaj c zmieniaj c si cyfr na odpowiedniej warto ci Has o dost pu umieszczone jest z tylnej strony panelu sterowania Potwierd ustawione has o naciskaj c przycisk wyboru funkcji Fazy...

Page 169: ...warto ci nale y przeprowadzi procedur regulacji CO2 Nale y sprawdzi czy g wny wymiennik jest czysty i wolny od zanieczyszcze Nale y sprawdzi i je li to konieczne przeczy ci przew d kondensatu aby zap...

Page 170: ...cjami zwi zanymi z limitami emisji gaz w Krzywa pr dko ci wentylatora rpm w zale no ci od mocy grzewczej c o qn c o 25HE Krzywa emisji CO w zale no ci od mocy grzewczej c o qn c o 25HE Moc grzewcza kW...

Page 171: ...0 80 90 100 110 120 130 140 150 160 170 180 190 200 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Krzywa pr dko ci wentylatora rpm w zale no ci od mocy grzewcazej c o qn c o 35HE 1000 1500 2000 25...

Page 172: ...id szelep 5 Biztons gi szelep 6 Keringet szivatty 7 Als leveg szell z szelep 8 Hidrom ter 9 Sziphon 10 Visszat r NTC szenzor 11 F st pr ba 12 F stelemz s minta kupak 13 F st k elvezet se 14 Hangtomp t...

Page 173: ...8 H romj rat szelep motorja 9 Keringet szivatty 10 Als l gtelen t szelep 11 T gul si tart ly 12 NTC rz kel a visszat r gon 13 F t k ri h cser l 14 NTC rz kel el remen gon 15 Fels l gtelen t szelep 16...

Page 174: ...et F Melegv z kimenet G Biztons gi szelep H Le r t szelep I Automata by pass L H romj rat szelep motorja M Keringet szivatty N Als l gtelen t szelep O T gul si tart ly P NTC rz kel a visszat r gon Q F...

Page 175: ...EN HE C S I R S I EXCLUSIVE GREEN HE C S I EN MULTI WIRE DIAGRAM ES ESQUEMA DE CONEXIONES PT DIAGRAMA DE FIA O M LTIPLA HU T BBVEZET KES RAJZ RO SCHEMA ELECTRICA MULTIFILARA SI ELEKTRI NA SHEMA PL SCH...

Page 176: ...REEN HE C S I R S I EXCLUSIVE GREEN HE R S I EN MULTI WIRE DIAGRAM ES ESQUEMA DE CONEXIONES PT DIAGRAMA DE FIA O M LTIPLA HU KAPCSOL SI RAJZ RO SCHEMA ELECTRICA MULTIFILARA SI ELEKTRI NA SHEMA PL SCHE...

Page 177: ...cendido V Hv Alimentaci n de potencia del ventilador HV 230V V Lv Alarma de control del ventilador BE06 Panel del circuito de mando de la bomba modulante PT DIAGRAMA DE FIA O M LTIPLA POLARIZA O L N R...

Page 178: ...klju itev zunanje opreme nizke napetosti M2 Sponke za priklju itev dodatne rpalke M3 M6 Sponke za priklju itev zunanje opreme visoke napetosti M4 Sponke za priklju itev tipala grelnika sanitarne vode...

Page 179: ...TIONS fig f Make the connections for the low voltage functions to the 10 pole low voltage connections terminal board M10 as indicated in the diagram Fit the P O S DHW time clock as shown in the diagra...

Page 180: ...o de 1 300 l h A bomba suplementar n o fornecida como um equipamento padr o mas deve ser escolhida cuidadosamente pelo instalador com base nas dimens es dos sistemas Para activar a bomba defina o par...

Page 181: ...go e oskrbovati napeljave s pretoki nad 1300 l h Dodatna rpalka ni prilo ena izbrati jo mora vgraditelj glede na zahteve napeljave Za vklju evanje rpalke je parametru 20 v na inu ogrevanje potrebno do...

Page 182: ...ES A salida condensado C gas agua PT A sa da condensada C gua g s HU A kondenzv z elvezet s C v z g z RO A evacuare condens C apa gaz SI A odtok kapljevine kondenza C voda plin PL A uj cie kondensatu...

Page 183: ...183 EXCLUSIVE GREEN HE C S I R S I C S I E F E F G R S I 1 8 1 9 C S I 1 6 1 7 A E A B D F A D F C C R S I...

Page 184: ...HU HELYIS GLEVEG F GG F STG Z ELVEZET S RO CONDUCT GAZE ARSE PENTRU INTRAREA N MEDIU SI CEV DIMNIKA DOVAJANJE ZRAKA V PROSTORIH PL POB R POWIETRZA DO SPALANIA Z POMIESZCZENIA 1 13 1 14 1 15 B23 B53 E...

Page 185: ...30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 B A C B A B C C EXCLUSIVE GREEN 25 HE M M M F EXCLUSIVE GREEN 35 HE M M M F EN M spring F horizontal flap ES Muelle M F aleta horizontal PT mola M aba ho...

Page 186: ...RTOM NY EN483 A f t si teljes tm ny kalibr lt rt ke ___________ kW ahol a ventil tor maxim lis sebess ge a f t s sor n _____________ ford perc D tum ____ ____ ____ Al r s______________________________...

Page 187: ......

Page 188: ...Cod 20082550 01 14 Ed 0...

Reviews: