6
EXCLUSIVE GREEN E C.S.I. - R.S.I.
Indication of the operating status
When the circulator is operating, the LED (B) is green. The four yellow
LED (C) indicate the electrical energy consumption (P1) as shown in
the following table.
LED status
Status
CIRCULATOR
Consumption in
% of P1 MAX (*)
Green LED on +
1 yellow LED on
Operating at the
minimum
0 - 25
Green LED on +
2 yellow LEDs on
Operating at the
minimum-medium
25 - 50
Green LED on +
3 yellow LEDs on
Operating at the
medium-maximum
50 - 75
Green LED on +
4 yellow LEDs on
Operating at the
maximum
100
(*) For the power (P1) absorbed by a single circulator, refer to the
“Technical Data” table.
Indication of the alarm status
If the circulator has detected one or more alarms the bi-colour LED (B)
is red. The four yellow LEDs (C) indicate the type of alarm as shown in
the following table.
LED status
ALARM
description
Status
CIRCULA-
TOR
Possible
REMEDY
Red LED
on +
1 yellow LED
on (LED 5)
The motor shaft
is blocked
Start attempt
every 1.5
seconds
Wait or
unblock the
motor shaft
Red LED
on +
1 yellow LED
on (LED 4)
Low input
voltage
Only a warn-
ing. The cir-
culator keeps
operating
Check the
input voltage
Red LED
on +
1 yellow LED
on (LED 3)
Problem with the
electrical supply
or else circulator
faulty
The circulator
has stopped
Check the
power supply
or else
replace the
circulator
b
When there are several alarms, the circulator will only display the
alarm with the highest priority.
Displaying the active settings
With the circulator powered up, briefly press the key (A) to display
the active configuration of the circulator. The LEDs indicate the active
settings.
No changes to the configuration of the circulator can be made in this
phase. Two seconds after the key (A) has been pressed, the user
interface returns to the normal display of the operating status.
Key lock function
The key lock function prevents any accidental modification of the
settings or the improper use of the circulator.
When the key lock function is activated, prolonged pressure of the key
(A) is inhibited. This prevents the user entering the section for setting
the circulator’s operating modes.
The key lock function can be enabled/disabled by pressing the key (A)
for more than 10 seconds. During this passage all the LEDs (C) blink
for 1 second.
> 10 s
Changing the operating mode
When operating normally the circulator works with factory settings or
the last setting carried out.
To change the configuration:
Make sure that the key lock function is disabled.
Press the key (A) for more than 2 seconds until the LEDs start to blink.
By briefly pressing the key (A), within 10 seconds the user interface
will pass to a display of the successive settings. The various available
settings will appear in a cyclical sequence
If the key (A) is not pressed, the last setting selected will be saved.
10 s
2 s
> 2 s
impostazione
visualizzazione
impostazione
visualizzazione
stato di
funzionamento
x
operating status
display
Setting
Setting
display
By pressing the key (A) it will be possible once again to pass to
“displaying the active settings” and check that the LEDs (B) and (C)
indicate, for 2 seconds, the last setting carried out
If the key (A) is not pressed for more than 2 seconds, the user interface
will pass to “displaying the operating status”.
The available settings are shown below together with the relative
representation of the LEDs (B) and (C).
LED 1
rosso
LED 2
giallo
LED 3
giallo
LED 4
giallo
LED 5
giallo
CC4
CC3
CC2
CC1
4 m
5 m
6 m
7 m
IMPORTANT
If curves 3 (5 metres) or 4 (4 metres) are set, you must replace the
bypass with the one supplied, respecting the following procedure:
- disconnect the electricity supply to the boiler by turning the main
system switch to OFF
- turn off the system taps and drain the heating circuit of the boiler
- remove the fixing clamp from the bypass cover (
D
)
- remove the bypass cover (
E
)
- replace the bypass valve (F) with the one supplied
- replace the bypass cover and the clamp.
D
F
E
C.S.I.
R.S.I.
D
F
E
LED 1
green
LED 2
yellow
LED 3
yellow
LED 4
yellow
LED 5
yellow
7m
6m
5m
4m