1 3
1 3
1 3
1 3
1 3
ENGLISH
ENGLISH
ENGLISH
ENGLISH
ENGLISH
Information
Press , the display turns off and just the word InFO appears (fig.
32). Press the button to view operating information. Press the
button again to move on to the next piece of information. If the
button is not pressed, the system automatically exits the function.
Info list:
Info 0
shows the word InFO (fig. 32)
Info 1
only with the external probe connected, displays external
temperature (e.g. 12 °C) (fig. 33).
The values shown on the display range between - 30 °C
and 35 °C.
Beyond these values the display shows “- -”
Info 2
shows circuit pressure (fig. 34)
36
37
35
34
33
32
Info 3
shows the set heating temperature (fig. 35)
Info 4
shows the set domestic hot water temperature (fig. 36)
Info 5
displays the set heating temperature, in reference to the
second circuit, only if it is connected.
S.A.R.A. function
If the “winter” mode is selected, the S.A.R.A. (Automatic Ambient
Adjustment System) function can be activated.
Turning the heating water temperature selector to a temperature
ranging between 55 and 65 °C the S.A.R.A. self-adjustment system
activates: depending on the temperature set on the ambient thermostat
and the time taken to reach it, the boiler automatically adjusts the
heating water temperature to reduce operating times, thereby
increasing operating comfort and energy saving.
It is possible to display information, which may be useful for the
Technical Assistance Centre, by pressing the button for 10
seconds: the code “INF2” appears on the display.
INF2
Step
Description
Display
Display
2 digits
4 digits
1
Input probe temperature
xx
01
° C
2
Return probe temperature
xx
02
° C
3
First water tank probe temperature (*)
xx
03
° C
4
Not used in this model
xx
Cond
° C
5
Fumes probe temperature
xx (**)
05
6
Second heating system probe temperature
xx
06
° C
7
Not used in this model
xx
07
8
Ventilator speed /100
xx
FAN
9
Not used in this model
xx
09
10
Not used in this model
xx
10
11
Exchanger cleaning counter status
bH
xxxx
12-19 Historic alarm codes
xx
HIS0-HIS7
INF2 list
Note (*):
if the water tank probe is faulty or disconnected, in the place of the value “- -” is displayed.
(**):
if the display also shows the dot (.), the temperature of the fumes probe is 100+displayed value