ENGLISH
16
MySMART
17
A
B
C
A. Operating status display
B. Settings display
C. Settings
Configuración
Iif the button (
A
) is pressed you can move back to the “active settings
display” again and check that the LEDs (
B
) and (
C
) indicate (for 2
seconds) the last setting carried out.
If the button (
A
) is not pressed for more than 2 seconds the user
interfaces switches to the “Operating status display”.
The available settings are shown in figure along with the related rep-
resentation of LED (
B
) and (
C
).
(*)
LED 1
R
LED 2
G
LED 3
G
LED 4
G
LED 5
G
(*) Factory set value
R red
G yellow
IMPORTANT
If the 3 (5 metres) or 4 (4 metres) curves are set the bypass must
be replaced with the one supplied, following the procedure indicated
below:
Remove boiler electrical power by setting the system's main switch
to off.
Close the system taps and empty the boiler heating circuit.
Extract the bypass body cover fixing spring (
D
).
Extract the bypass body cover (
E
).
Replace the bypass valve (
F
) with the one included.
Refit the bypass body cover and its spring.
D
F
E
D
F
E
Eventual releasing of the circulator shaft
-
I
nsert a screwdriver in the hole (
1
) of the circulator
- Press (
a
) and turn the screwdriver (
b
) until the release of the crank-
shaft.
Perform this operation with extreme caution to avoid damaging
the components.
1
a
b