background image

11

INSTALLER

10  UNPACKING THE PRODUCT

MODELS IDRA N DS 1500

B

 

IDRA N DS

 storage cylinders are delivered in a single 

package, protected by a plastic bag inside a protective 

foam rubber wrapping and supported by a wooden pallet.

-  The following items are delivered in a plastic bag in-

side the packaging:

-  Instruction manual

-  Bar code label

-  Hydraulic test certificate

The two magnesium anodes are supplied in a cardboard 

box on the pallet.

A

B

H

IDRA N DS

A (mm)

B (mm)

H (mm)

Weight 

(kg)

1500

1000

1000

2325

340

The instruction manual is an integral part of the so-

lar storage cylinder. Once located, read it thoroughly 

and keep it safe.

MODELS IDRA N DS 2000

B

 

IDRA N DS

 storage cylinders come in two separate 

packages:

-  The first contains the painted cylinder, protected by a 

plastic bag and supported on a wooden pallet.

-  The second package, also protected by a plastic 

bag, contains the polyurethane insulation with its 

elegant outer covering, fitting insulation sleeves, top 

cover, flange cover, identification plates and docu-

mentation.

The following items are delivered in a plastic bag inside the 

packaging:

-  Instruction manual

-  Bar code labels

-  Hydraulic test certificate

The two magnesium anodes are supplied in a cardboard 

box on the pallet.

A

B

H

IDRA N DS

A (mm)

B (mm)

H (mm)

Weight 

(kg)

2000

1700

1900

2000

565

The instruction manual is an integral part of the so-

lar storage cylinder. Once located, read it thoroughly 

and keep it safe.

Installer

Summary of Contents for 20052790

Page 1: ...Installation and Operation Manual Solar solar storage cylinder IDRA N DS Installation and Operation Manual EN...

Page 2: ...2...

Page 3: ...by improper installation adjustment maintenance or use RANGE MODEL CODE IDRA N DS 1500 20052790 IDRA N DS 2000 20052791 IDRA N DS 2600 20086803 ACCESSORIES For a complete list of accessories and detai...

Page 4: ...power switch Drain the central heating circuit and domestic hot water circuit if there is any risk of freezing b This instruction manual is an integral part of the pro duct It must be kept safe and m...

Page 5: ...20052790K4LH3800001 Model IDRA N DS 1500 Code 20052790 Serial Number K4LH3800001 Beretta Caldaie Via Risorgimento 13 23900 Lecco LC Italy Capacit nom sanitaria 1449 L 1 8 mq 3 4 mq 1200 L h 2200 L h...

Page 6: ...m2 Top coil heat exchange surface area 1 8 2 8 3 3 m2 Maximum operating pressure of storage cylinder 8 bar Maximum operating pressure of coils 6 bar Maximum operating temperature 99 C Net weight with...

Page 7: ...OP mbar 600 500 400 300 200 100 0 0 1000 2000 3000 5000 6000 4000 1500 2600 2000 FLOW RATE l h Pressure drops BOTTOM COIL PRESSURE DROP mbar 1000 900 800 600 400 100 200 300 500 700 0 0 1000 2000 3000...

Page 8: ...low rate from the solar collector circuit depends on the type and number of collectors installed For further infor mation consult the manual for the collectors b The domestic hot water system MUST INC...

Page 9: ...e proper water glycol mix Risk of freezing b All piping collectors heat exchangers and other de vices in the circuit must be subjected to proper hy draulic seal testing 8 LOCATION OF SENSORS B IDRA N...

Page 10: ...1 2 F 1 1 4 F Psc1 Diameter length of boiler sensor socket 1 2 F mm Psc2 Diameter length of boiler sensor socket 1 2 F mm Psr Diameter length of solar controller sensor socket 1 2 F mm RE Sleeve for e...

Page 11: ...ep it safe MODELS IDRA N DS 2000 B IDRA N DS storage cylinders come in two separate packages The first contains the painted cylinder protected by a plastic bag and supported on a wooden pallet The sec...

Page 12: ...equipment and use suitable safety devices b Make sure that any lifting equipment is of adequate capacity to lift and move the storage cylinder a Do not dispose of packaging material into the envi ron...

Page 13: ...storage cylinder from the pallet cut the straps secure the lifting cables to the lifting points on the top of the storage cylinder carefully lift the storage cylinder and position it as re quired 12...

Page 14: ...npack all the material from the second package Wrap the insulation 3 around the storage cylinder carefully lining up the fittings with the holes on the inside of the insulation Secure the insulation i...

Page 15: ...orage cylinder is to be installed 15 INSTALLATION IN OLDER SYSTEMS AND SYSTEMS REQUIRING MODERNISATION When installing B IDRA N DS storage cylinders in old systems or systems requiring modernisation a...

Page 16: ...ion Make sure that all circuits have been bled Make sure that the boiler and solar collectors con nected to the system shut down correctly when their mains power switches are turned OFF Provided the a...

Page 17: ...cylinder after cleaning it a Do not use abrasive products petrol or triethylene INTERNAL CLEANING Removing and checking the magnesium anode Remove the cap 1 cover 2 and the anode insula tor disc 1 2 U...

Page 18: ...functioning Check the pump The water temperature from the boiler is too low Check the temperature setting There is air in the primary circuit Bleed the circuit SOLAR COLLECTOR CIRCUIT FAULT CAUSE SOLU...

Page 19: ...t on the environment and save energy before leaving for the weekend or a short break etc pro vided outdoor temperatures will remain above ZERO sim ply adjust the storage cylinder s thermostat to its m...

Page 20: ...boilers com Beretta reserves the right to modify the characteristics and specifications given in this publication at any time and without prior notice as part of its policy of continuous product impro...

Reviews: