21  start-UP

The storage cylinder must be put into service for the first 

time by personnel from the manufacturer’s Technical Assi-

stance Centre.

Under certain circumstances, such as after long periods of 

disuse, the user may need to re-start it without involving the 

Technical Assistance Centre. Before doing so, perform the 

following checks and operations.

 - Check that the supply cocks in the domestic water circuit 

are all open.

 - Switch the electricity supply ON at the mains power swi-

tch and at control panel switch (if fitted).

22  teMPorary sHUtdoWn

To reduce impact on the environment and save energy, 

before leaving for the weekend or a short break, etc., pro-

vided outdoor temperatures will remain above ZERO, sim-

ply adjust the storage cylinder’s thermostat to its minimum 

temperature.

 

b

If outdoor temperature may drop below ZERO (risk 

of freezing) perform the operations described in the 

“Preparing for extended periods of disuse” section.

23  PreParing for extended 

Periods of disUse

If the storage cylinder is not going to be used for an exten-

ded period of time, ask the manufacturer’s Technical Assi-

stance Centre to make the system safe.

24  external Maintenance

Clean the cover, painted and plastic parts with a cloth dam-

ped in soap and water. To remove stubborn marks, use a 

cloth damped in a 50% mix of water and denatured alcohol 

or a suitable cleaning product.

 

b

Do not use fuels, sponges impregnated with abrasive 

solutions or powder detergents.

End user

Summary of Contents for 20015324

Page 1: ...solar storage cylinder IDRA MS INSTALLATION MANUAL USER MANUAL SOLAR...

Page 2: ...ersonnel are specially trained to keep your solar storage cylinder effi cient and cheap to run B service centres also stock any original spare parts that might be required This manual contains importa...

Page 3: ...ecifications 6 7 Water circuit 7 8 Location of sensors 8 9 Overall dimensions and water fittings 9 INSTALLER 11 10 Unpacking the product 11 11 Handling 11 12 Place of installation 12 13 Installation i...

Page 4: ...must be mixed with water in a percentage varying from 30 to 50 as instructed in the B installation and maintenance manual b b Only fill the solar collector primary circuit with water and glycol premi...

Page 5: ...ermoacumulador l T067659EPE02 Conexi n a tierra obligatoria Liga o terra obrigat ria Obligatory ground connection W Pot ncia el ctrica consumida Pot ncia consumida max pela serp sup T Prim rio 80 C kW...

Page 6: ...450 33 520 mm Flange diameter 118 mm Diameter length of sensor sockets 16 175 mm Sleeve for electric heating element not supplied 1 F Coil water capacity 5 7 9 3 11 12 8 l Coil heat exchange surface...

Page 7: ...lector probe Note The above schematic is purely indicative b b B IDRA MS storage cylinders are delivered without a boiler heating pump A suitably rated pump must be provi ded and installed separately...

Page 8: ...the boiler and solar collectors Installers must use their expertise to ensure proper installation and functioning in compliance with all applicable legislation Psr B A C A Temperature sensor socket B...

Page 9: ...iameter length of solar controller sensor socket 16 175 mm RE Sleeve for electric heating element not supplied 1 F mm AD Diameter length of magnesium anode 33 450 33 520 mm TR Temperature gauge DSA Se...

Page 10: ...lar controller sensor socket 16 175 mm RE Sleeve for electric heating element not supplied 1 F mm AD Diameter length of magnesium anode 33 450 33 520 mm TR Temperature gauge DSA Sensor power cable ent...

Page 11: ...n hand to lift the storage cylin der off the pallet using the eyebolt proceed as follows Place a platform of about half the height of the pallet near the storage cylinder Make sure the platform is abl...

Page 12: ...one Silicon ions less than 30 ppm Technical Assistance Centre 14 Putting into service It is essential to perform the following checks before star ting up or testing the functioning of the storage cyli...

Page 13: ...Centre or by a qualified heating engineer at least once a year Perform the following operations before beginning any maintenance Switch the electricity supply to the storage cylinder s val ve group a...

Page 14: ...limiter Fit a flow reducer There are blockages or deposits in the domestic hot water circuit Check and clean as necessary The pump is malfunctioning Check the pump The water temperature from the boile...

Page 15: ...on the environment and save energy before leaving for the weekend or a short break etc pro vided outdoor temperatures will remain above ZERO sim ply adjust the storage cylinder s thermostat to its min...

Page 16: ...C Italy Customer Service 199 13 31 31 www berettaclima it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessorie...

Reviews: