45
Product information
6003884_0 – 22.08.2017
EN
2.
Product information
2.1
Product overview
The device extends the functionality of the ceiling lift hood.
All of the device’s functions are controlled by the ceiling lift
hood.
Observe the ceiling lift hood instructions.
The filter filling in the recirculated air filter neutralises any
smelly odours present. The odour-free, cleaned room air is
fed back into the room. The humidity in the room can be
reduced with the fresh air feed.
Filter mats, special active charcoal and a catalytic converter
are used in the device for effective odour absorption. After a
certain number of operating hours, the regeneration process
takes place in the closed filter. The catalytic converter starts to
regenerate the filter material automatically.
The regeneration process starts after approx. 30 minutes
of constant operation or after approx. 60 minutes of total
operating time, directly after turning the extractor hood off.
The regeneration process takes approx. 120 minutes.
The generation of heat and noise is perceivable at the
device during this time.
The device is used in recirculated air mode. In recirculated air
mode, it is necessary to use the run-on function so that the
device can remove the remaining odours.
A
B
C
D
A Recirculated air filter permalyt® BUR BDL
B Ventilation flaps
C Mains cable with Wieland plug for connection to the
ceiling lift hood power supply
D Cable with 4-pole plug for connection to the ceiling lift
hood controller
2.2
Scope of delivery
B
A
A Recirculated air filter permalyt® BUR BDL
B Assembly instructions
2.3
Technical data
BUR BDL
95
BUR BDL
115
Connection voltage
230 V / 50 Hz
230 V / 50 Hz
Power consumption
approx. 100 W approx. 100 W
Air inlet
ø 150 mm
ø 150 mm
Width
378 mm
478 mm
Depth
246 mm
246 mm
Height
192 mm
192 mm
Net weight
5 kg
7 kg
Information on the model (e.g. serial number, year of
construction) can be found on the typeplate.