88
Installation
6002644_0 – 20.01.2016
Formline headroom hood
x
465
45
270
510
30
290
=
=
400
Safety distance (x):
y
Recommendation 600 mm.
y
With gas hobs, at least 650 mm.
☞
Determine the hanging position.
☞
Ensure that the chimney mount is correctly positioned:
y
The chimney cannot be mounted if it falls below the
required measurements (30 mm).
y
Any irregularities (e.g. in the ceiling) can be
compensated with slotted holes.
☞
Make sure that the safety distance is complied with.
WARNING
Hazard due to explosions or electric shock.
Drilling through gas, water or electrical lines can lead to
hazardous situations.
☞
Ensure that there are no lines in the wall at the fastening
points.
Ø 8
☞
Determine the locations of the fastening points and mark
them.
☞
Drill the holes in the wall.
☞
Insert the wall plugs into the holes.
☞
Screw the chimney fastening bracket on.