![Beper VE.510 Use Instructions Download Page 11](http://html1.mh-extra.com/html/beper/ve-510/ve-510_use-instructions_2735983011.webp)
EN
Mist Fan Use instructions
11
PRODUCT DESCRIPTION Fig.A
1. Nebulizing ring
2. Tube
3. Front grid
4. Grid closure hooks
5. Blade mounting ring
6. Blade
7. Rear grid fixing ring
8. Rear grid
9. Motor unit
10. Control panel
ASSEMBLING THE FAN
To fix the casters, turn the base upside down and insert the casters complete with plastic cap in the dedicated
holes. Note: it will not be possible to insert the casters without the plastic cap.
Fix the control panel structure to the base by screwing the fixing nut placed under the base.
Place the rear grid in its housing and secure it by turning the rear grid fixing ring clockwise.
Insert the blade and secure it by turning the blade mounting ring counter clockwise.
Place the front grid and firmly close it with the appropriate hooks and screw.
Connect the top tube by inserting it into the appropriate housing placed in front of the front grid. Open the front
part of the control panel structure by gently pulling towards you to remove the tank.
Take the water tank, turn it upside down and unscrew the cap placed at the bottom.
Fill the tank with water, close the cap and place it back to its position.
Important: Make sure that all components are firmly fixed to the base in order to ensure a good stability
of the fan, otherwise the fan would oscillate dangerously
OPERATION BY CONTROL PANEL: Fig.B
When the assembly is complete, plug in the appliance.
The ON indicator turns blue.
The default operating mode of the fan is set on NORMAL mode and to WEAK speed (the indicators light up when
the fan is turned on).
By pushing the
ON/SPEED
button, the blade is activated and the desired fan speed is selected (based on your
setting, the blue LED indicator turns on: WEAK, MIDDLE or STRONG).
The
OSCILLATION
button activates the horizontal automatic oscillation of the head of the fan (the OSCILLA-
TION indicator turns blue on the panel). Oscillation allows even distribution of air flow through the environment.
To deactivate oscillation, just press the OSCILLATION button again (the LED indicator on the panel turns off).
The
HUMIDIFIER
button activates/deactivates water mist (the HUMIDIFIER indicator on the panel turns on/off).
!!!IMPORTANT!!! Before selecting water mist function, always make sure that the water tank is full.
The
TIMER
button allows to set the time of switching on/off of the fan.
To set the switching on of the fan, make sure that the fan is OFF but connected to the wall socket, and press
the TIMER button (the LED screen will show the time set, in hours). The TIMER is set with 1 hour progression,
up to 12 hours.
To set the switching off of the fan, press the TIMER button when the fan is ON (the LED screen will show the time
set, in hours). In this case also, the TIMER is set with 1 hour progression, up to 12 hours.
Press the OFF button to turn the fan off.
11. Motor unit fixing screw
12. Water tank
13. Tank closure cap
14. Base
15. Fixing ring for base
16. Casters
17. Plastic cap for casters
18. Remote control
Summary of Contents for VE.510
Page 3: ...Fig A Fig B...