EZ Mount Installation (Surface Mount Only)
1. Disconnect battery positive leads at the batteries for safety
2. Choose mounting location on a flat surface close to the
batteries
3.
Select pan head (or similar) screws for mounting - use either
M5 or 10g imperial (not included)
4. With Actuator removed, use the switch base as a mounting
template to mark the hole positions. (See separate
instructions for Actuator removal/fitting)
5.
Drill holes and screw switch base into position
6. Connect cables to studs ensuring that batteries and loads are
correctly fitted
7.
Ensure cables are secured to ISO/ABYC standards, and that
cables are supported so they are not placing unnecessary
strain on the battery switch studs
8. Check that spring washers are fitted beneath nuts
9.
Tighten the stud nuts to 13.5 Nm (10 lbf)
10. Slot the side panel(s) into the Actuator as required
11. Replace Actuator, ensuring that both switch base and
Actuator are both in their “OFF” positions
12. Lock the Actuator fastening screws
13. With switch in “OFF” position connect battery positive leads
at battery
14.
Check switch operation
Check switch operation:
a. Loads have no voltage in “OFF” position
b. Loads have voltage from battery 1 in “1 ON” position
c. Loads have voltage from battery 2 in “2 ON” position
d. All connections are paralleled in “1&2” position
Fit Actuator at
0, 90, 180, or
270 degrees
to suit cabling
ON
ON
1&2
1
2
OFF
ON
ON
1&2
1
2
OFF
ON
ON
1&2
1
2
OFF
ON
ON
1&2
1
2
OFF
Off Position For
Switch Base, When
Arrow On Shaft
Points At "OFF"
Always remove &
replace Actuator with
knob in the "OFF"
position
OFF
ON
ON
1&2
1
2
Replacement of Actuator (always remove, and replace the
Actuator with knob in the “OFF” position)
1.
Check that switch contact shaft (on base) hasn’t been rotated, and
that arrow on base shaft is pointing towards “OFF” engraving
2. Ensure that that light grey fastening screws are in the “unlocked”
position
3. Ensure that Actuator knob is rotated to the “OFF” position
4.
Note that Actuator can be fitted at any position 0/90/180/270 to suit
electrical cabling
5.
Replace Actuator
97.8 [3.85]
15.6 [0.61]
76.9 [3.03]
92.5 [3.64]
62.4 [2.46]
30.1 [1.19]
27.5 [1.08]
97.8 [3.85]
97.8 [3.85]
76.2 [3.00]
76.2 [3.00]
5.5 [0.22]
Dimensions:
Removal of Actuator (always remove, and replace the
Actuator with knob in the “OFF” position):
1.
Ensure knob is on “OFF” position
2. Undo light grey fastening screws by rotating 45 degrees
anticlockwise
3.
Remove Actuator
UNLOCKED
LOCKED
ON
ON
1&2
1
2
OFF
Surface
EZ-Mount
Rear
Panel
Mount
Front
Panel
Mount