13
CZONE Display Interface Operations Manual
Display Interface
Dimensions: H x W x D - 105 x 165 x 62 mm
4
3
/
32
x 6
7
/
16
x 2
13
/
32
in
Weight:
374 g
DC Power Meter:
Displays voltages of multiple battery banks with low and high voltage alarms;
charge and discharge (amps) of multiple battery banks; battery capacity in ampere
hours and % charge/discharge; includes low ampere hour alarm.
AC Power Meter:
Displays multiple line voltages (230 and 110 V with low and high voltage alarms);
AC line frequencies (includes high and low frequency alarm for each); AC power
consumption in kW (calculation uses power factor for true RMS).
Fluid level display:
Displays multiple tank levels/multiple fluid types such as Diesel/Gas/Fresh water/
Black water/Grey water; switching thresholds can be set for tank levels to raise
alarms or to control an output i.e. a ballast pump can be automatically controlled via
the ballast water level.
Switching channel control:
All DC control circuits can be toggled on or off, dimmed or motors reversed.
Systems in operation:
Displays operation of circuits of interest ie Bilge pumps, engine room lights etc;
systems faults and alarm conditions (programmable); Repeater for other NMEA 2000
broadcasted data.
Inputs:
Network, NMEA 2000, 5 – 35 V DC
EMC ratings:
IEC EN 60945, IEC EN 61000, FCC Class B.
ISO 7637 - 1 (12 V Passenger cars and light commercial vehicles with nominal 12 V
supply voltage - Electrical transient conduction along supply lines only).
ISO 7637 - 2 (24 V Commercial vehicles with nominal 24 V supply voltage - Electrical
transient conduction along supply lines only).
IEC Standards for indirect lightning strikes.