      F1.2: Calibration mode selection, with 2 options
      F1.2=1  fixed point calibrating
      F1.2=2  arbitrary point calibrating

       

Note: If the version number is less than REV2.0, choose F1.2=2 only

      F1.3: Baud rate selection, with total 5 options
      F1.3=1   B =600
      F1.3=2   B =1200
      F1.3=3   B =2400
      F1.3=4   B =4800
      F1.3=5   B =9600

      F1.4:  Auto shut-off function selection, with 3 options
      F1.4=0  disabled
      F1.4=3  auto shut-off in 3 minutes after stopping operating
      F1.4=5  auto shut-off in 5 minutes after stopping operating

      F1.5: Key sound selection, with 2 options
      F1.5=0  disabled
      F1.5=1  allowed

      F1.6: Setup value selection from F1.1 to F1.5, with 2 options
      F1.6=1  select setup value of customer
      F1.6=2  select the default value , see the following table:

  Note: After the F1.6 is selected and press [ENTER] to confirm, the indicator
            will display “ F1” again.   To re-enter by pressing [ENTER] and press [EXIT]
            to withdraw. And also to press [

] to  re-select main directories.

    5.2.2 Subdirectories  F2
     F2.1: Turn-on zero setting range selection, with 4 options
     F2.1=0   disabled
     F2.1=5      

±

5%F•S

     F2.1=10    

±

10%F•S

     F2.1=20    

±

20%F•S

 F1.1

 F1.2

 F1.3

 F1.4

 F1.5

1

2

2

5

1

Table 1

11

Summary of Contents for HPS - 1 AE

Page 1: ...ENGLISH PYC1 3t ELECTRONIC PALLET SCALE Using brochure...

Page 2: ...Calibration Disclaimer We ve been tried to provide complete and accurate information in this manual however we make no representations and warranties with respect to the contents of this manual and r...

Page 3: ...Basic counting function 1 10 Weight unit converting 1 11 Beep sound selection 1 12 Auto shut off function 1 13 Ticket print HPS 1 AU HPS 1 BU HPS 1 CU HPS 2 AU HPS 2 BU HPS 2 CU HPS 1 AE HPS 1 BE HPS...

Page 4: ...diagram Note The pallet scale can be disassembled into three main parts for transportation Please refer to the above assembly diagram for installation Figure 1 Handle Indicator Box Pallet Platform Sca...

Page 5: ...8 9 6 10 11 12 13 2 3 4 5 1 lb weight unit kg weight unit Counting state indicating Zero position indicating Stable weighing indicating Totalizing effective cursor Auto backlight function switch on c...

Page 6: ...y return to zero of not more than 5 Max capacity Once pressing this key 0 cursor appears b Under calibrating state this key is used for selecting digit place Press this key once the selected digit wil...

Page 7: ...y value converting be tween gross weight and net weight c Under counting state press this key to make the display value converting be tween the sample number and the weight Clearing key a Under weighi...

Page 8: ...as follows Step 1 Press once to make the indicator display 00000 0 the digit at the last right place flashes Step 2 Press once the second digit flashes and 0000 0 0 is displayed Step 3 Press once the...

Page 9: ...ctive 0 on high 4 digit will be omitted But if the high 4 digit are all 0 only one 0 at the last place will be displayed i e H 0 H 0 H 0 H 0 H 0 b Repeat totalizing To compare with the last or first t...

Page 10: ...e if there is any change of the weight or keypad being pressed its backlight will automatically turn on for 10 seconds and then turn off b Manual mode While manual mode is selected Auto BL cursor disa...

Page 11: ...the same time the indicator will back to self checking process 4 8 7 Turn off power supply and pull out its power plug at once if it is out of order in use Non professional staff can t repair it with...

Page 12: ...will select the main directories in F2 F3 F1 F2 sequence Press ENTER to enter any subdirectory under the main directories Press I O and C at the same time to back to the entrance self checking 5 2 Su...

Page 13: ...5 minutes after stopping operating F1 5 Key sound selection with 2 options F1 5 0 disabled F1 5 1 allowed F1 6 Setup value selection from F1 1 to F1 5 with 2 options F1 6 1 select setup value of custo...

Page 14: ...with 6 options F2 2 00 disabled F2 2 0 2 0 2d F2 2 0 5 0 5d F2 2 1 0 1 0d F2 2 2 0 2 0d F2 2 3 0 3 0d F2 3 Filtering selection with 3 options F2 3 1 low degree weak air wind flow or little atmospheric...

Page 15: ...raise quality Focusing on improving ADD No 8 Laoshan road Dagang industry city Ningbo economic development zone TEL 86 574 8680 6868 FAX 86 574 8680 6862 E mail sales benui com office benui com http w...

Reviews: