8 STEP 

 

 

 

 

 

 

 

 

 

12V  5A 

 
BENTON 
 
ICEMAN 5.0 BLE 
 
SWITCH MODE BATTERY CHARGER 
 
For Lead acid batteries 

1.2-120Ah (charging), up to 160 Ah for maintenance

 

             
 
 
User’s manual and guide to professional battery charging 
 

 

 

 
 
 
 

 
 

 
 

 

 

 
 
 

 
 
For Your Safety 

This  manual  contains  important  safety  and  operating  instructions.  Read  this  manual 
carefully before using the charger for the first time and keep the manual in a safe place 
for future reference. 

Mode Button 

Power LED 

Error LED 

Ready To Use 

Fully Charged 

Normal Battery Mode 

Small Battery Mode 

Cold Mode 

Boost Mode 

Cold Mode 

Boost Mode 

Summary of Contents for ICEMAN 5.0 BLE

Page 1: ...rofessional battery charging For Your Safety This manual contains important safety and operating instructions Read this manual carefully before using the charger for the first time and keep the manual...

Page 2: ...nals 6 3mm with in line battery protection fuse 10A for permanent attachment to the battery posts to allow quick connection disconnection through snap connector 4 User Manual AC Plug Mains Cable H05RN...

Page 3: ...hassis first The other connection is to be made to the terminal connected to the chassis far from the battery and fuel line The battery charger is then to be connected to the power supply After chargi...

Page 4: ...0 3A This mode is suitable to recover severely discharged AGM batteries smaller than 14 Ah or charging in sub zero temperatures Mode 14 4V 5 0A This mode is normally used for WET MF VRLA AGM GEL and...

Page 5: ...rger diameter than a negative post c Identify the pole of battery which is connected to the chassis earth Normally the negative terminal is connected to the chassis d Charging of negative earthed batt...

Page 6: ...ads the power cord should be removed from the mains b Connect the red clamp or eyelet terminal to the positive pole of the battery and the black clamp or eyelet terminal to the negative pole 3 Connect...

Page 7: ...nt Temperature 30 C to 50 C Reduced output power at higher temperature Type of Charger Eight step fully automatic switch mode with maintenance charging Type of Batteries 12V Lead acid rechargeable bat...

Page 8: ...current 4 Absorption With use of declining current charging up to almost 100 is achieved 5 Analysis Checks status of charge If battery does not retain energy it must be replaced 6 Boost Recovers sever...

Page 9: ...cannot be de sulfated it must be replaced No charging Phases Flashing Charger is not connected to battery over 2 mins Charger is in energy save mode For ICEMAN 5 0 BLE Bluetooth Description Battery Ch...

Page 10: ...hich can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna...