Calibration Procedure
(A)
Auto Calibration (OB, AGC/WB
、
Meshut26
、
Meshut 80) & Infinite Focus Calibration
1.
Insert the battery into the camera and press “Power, Playback, Tele and Set” button to access the
auto test mode.
2.
The on screen display shows the “OB CLBT” message (Fig. 1). Put the camera in front of light source
box and make sure the camera is close to light source box tightly or you can shoot the black subject.
3.
Tap “OK” button and the press “Set” button to test automatically. . When the dialogue box showed
“OK”(Fig. 2), it means the test is passed. If it shows “NG”, it means the test was failed.
4.
Press the “Fn” button to back the main menu and select the AGC/WB.
5.
The on screen display shows the “AGC/WB” message (Fig. 3). Put the camera in front of the light
source box and the LV setting is LV10.
6.
Tap “OK” button and then press “Set” button. Calibration program will execute automatically.
7.
When the on-screen display shows “OK” (Fig. 4), it means the test is passed. If it shows “NG”, it means
the test was failed.