Indirect length calculation 

The indirect length calculation is intended for determining certain distances using length 
measurements to various points and angle measurements of the respective axes. 

 Indirect length calculation 1 

1.  Point the laser beam at the first measuring point (A). 
2.  Press the “Measurement” key.  

The measurement is started and the measured value will be 
shown on the digital display. 

3.  Point the laser beam perpendicularly to the surface at the 

second measuring point (B). 

4.  Press the “Measurement” key. 

The measurement is started and the second measured value 
will be shown on the digital display. 
The device calculates the distance between the two 
measuring points from the measurements and the determined 
value will be shown on the digital display. 

 / 

 Indirect length calculation 2 / 3 

1.  Point the laser beam at the 

first measuring point (A). 

2.  Press the “Measurement” 

key. 
The measurement is started 
and the measured value will 
be shown on the digital 
display. 

3.  Point the laser beam at the 

second measuring point (B). 

4.  Press the “Measurement” 

key. 

The measurement is started and the second measured value will be shown on the digital 
display. 

5.  Point the laser beam perpendicularly to the surface at the third measuring point (C). 
6.  Press the “Measurement” key. 

The measurement is started and the third measured value will be shown on the digital 
display. The device calculates the distance between the measuring points A and B from the 
measurements and the determined value will be shown on the digital display. 

 Indirect length calculation 4 

1.  Point the laser beam at the measuring point (A). 
2.  Press the “Measurement” key. 

The length measurement and angle measurement (in relation 
to the horizontal) are started and the measured values will be 
shown on the digital display. The device calculates the 
distance between measuring point A and the horizontal 
perpendicular (with respect to the distance to be calculated) 
from the measurements. The determined value will be shown 
on the digital display. 
 

 / 

 Indirect length calculation 5 / 6

 

1.  Point the laser beam at the 

first measuring point (A, 
above the horizontal 
perpendicular with respect to 
the distance to be 
calculated). 

2.  Press the “Measurement” 

key. 
 
 

The length measurement and angle measurement (in relation to the horizontal) are started 
and the measured value for the length will be shown on the digital display. 

3.  Point the laser beam at the second measuring point (B, indirect length calculation 5: below 

the horizontal perpendicular, indirect length calculation 6: above the horizontal 
perpendicular with respect to the distance to be calculated). 

4.  Press the “Measurement” key. 

The length measurement and angle measurement (in relation to the horizontal) are started 
and the measured values (angle between measuring points A and B) will be shown on the 
digital display. The device calculates the distance between the measuring points A and B 
from the measurements and the determined value will be shown on the digital display. 

 Digital spirit level (axis)

 

 

The digital spirit level (axis) is intended for measuring an angle of 
an axis in relation to the horizontal and for displaying the 
corresponding inclination. 
1.  Place the device flat onto the surface to be checked. 
2.  Align the device. The axis of the device must correspond to 

the axis to be checked. 
The measured value will be shown on the digital display and a 
digital spirit level indicates the inclination. 
In horizontal position, the alignment point (“bubble”) is exactly 
between the two markings and will be displayed in green. 

 Digital spirit level (surface) 

The digital spirit level (surface) is intended for displaying an inclination of a surface in relation 
to the horizontal. 
1.  Place the device onto the surface to be checked. 

The digital spirit level indicates the inclination. In horizontal position, the alignment point 
(“bubble”) is exactly within the inner marking and will be displayed in green. 

 Stake-out function 

The stake-out function is intended for dividing a distance into 
previously set subsections of equal lengths. 
1.  Set the desired length of the subsections. 
2.  Press the “Measurement” key. 
3.  Point the laser beam at the measuring point. 
4.  Press the “Measurement” key. 

The measurement is started and the following values will be 
shown on the digital display: 
-  Set length of the subsections (setting) 
-  Number of subsections with respect to the measured 

distance (measured value) 

-  Measured distance (measured value) 
-  Yellow arrows on the top and bottom of the digital display: display in which direction the 

next complete subsection is located (integer). 

5.  Reposition the device accordingly. 

Press the “Measurement” key to interrupt the measurement and press the “Menu” key to 
exit the measuring function. 

 Measuring units 

 

Metre 

Centimetre 

Millimetre 

Foot 

Inch 

Length 

cm 

mm 

ft 

in 

Area 

m² 

m² 

m² 

ft² 

ft² 

Volume 

m³ 

m³  

m³ 

ft³ 

ft³ 

 

 Settings 

 Key tones (volume / OFF)

  

 Automatic rotation of the digital display ON / OFF 

 Opening the measured value memory / deletion via 

 

 Calibrating the spirit level (observe operating manual!) 

Further measuring functions 

For more detailed information or for information on further measuring functions (e. g. 
calibration of the spirit level, measured value memory, addition / subtraction of measured 
values), please refer to the operating manual on the Internet at 

http://tms.benning.de/ld40-ld60

 . 

Error messages 

Code 

Description 

Remedial measure 

Err01 

Measured value outside 
measuring range  

Carry out the measurement within the 
measuring range. 

Err02 

Reflected signal too weak 

Carry out the measurement at a measuring 
point with a different surface. 

Err03 

Measured value outside of 

display range (max. 99 999) 

 

Divide the measurement into smaller 
subsections. 

Err04 

Pythagoras calculation failed  Check whether the measured values are 

correct and the correct measuring sequence 
has been observed. 

Err05 

Low battery 

Replace the batteries of the device. 

Err06 

Ambient temperature 
outside the operating 
temperature 

Carry out the measurement at a permissible 
ambient temperature. 

Err07 

Ambient light too bright 

Carry out the measurement in a darker 
environment. 

Disposal and environmental protection 

At the end of product life, dispose of the unserviceable device and the batteries via 
appropriate collecting facilities provided in your community. 