Safety

2.4 Intended use

5190 / 04/2021 en

BENNING TA 6

11

2.4

Intended use

Only use the device within the framework of the corresponding technical data. Any operating
conditions that deviate from this shall be considered as improper use. Solely the user of the
device shall be liable for any resulting damage.

In particular, note the following:

• In case of improper use, the liability and warranty claims become void. Solely the user of the

device shall be liable for any damage resulting from improper use. Uses not complying with
the intended use include e. g.:

– Use of components, accessories, spare or replacement parts that have not been

released and approved for the respective application by Benning

– Non-observance, manipulation, changes or misuse of the operating manual or the

instructions and notes contained therein

– Any form of misuse of the device

– Any use other than or beyond that described in this operating manual

• Warranty and liability claims are generally excluded if damage is due to force majeure.

• If any prescribed services are not performed regularly or not on time according to

manufacturer specifications during the warranty period, a decision about a warranty claim
can only be made once the findings are available.

Direct any questions to Technical Support [

}

 page 8].

Using the device

Please observe the following basic obligations when using the device:

• The device may only be used in a technically perfect and safe condition. Always check the

device for damages before using it.

• Make sure the personnel using the device is qualified for the respective task.

• Observe relevant regulations on occupational safety and health as well as those on

environmental protection.

• The device may only be used in dry environments.

• Use the device exclusively for measuring purposes with the BENNING IT 115, IT 130 and

IT 200 installation testers. In addition, observe the operating manual of the installation
tester.

• The device is intended for short-time use only (continuous operation is not permitted).

Disconnect the device from the test object after use.

• Use the device only in electric circuits of overvoltage category II with a conductor for a

maximum of 300 V to earth.

 WARNING

Opening the device

Danger to life or serious injury is possible due to contact with high electric voltage when opening
the device. The device might get damaged.

• Do not open the device.

• Please contact your specialty retailer or the returns management [

}

 page 8] for any repairs.

Summary of Contents for 044168

Page 1: ...BENNING TA 6 Operating manual Translation of the German original version 5190 04 2021 en...

Page 2: ...ights reserved This document particularly all of the contents texts photographs and graphics that it contains are protected by copyright No part of this documentation or the associated contents may be...

Page 3: ...2 3 Symbols used 10 2 4 Intended use 11 2 5 Special types of risks 12 3 Scope of delivery 13 4 Device description 14 4 1 Device structure 14 4 2 Functions 15 5 Operation 16 5 1 Testing with an instal...

Page 4: ...Table of figures Table of figures Figure 1 BENNING TA 6 device structure 14 Figure 2 Switch positions of the BENNING TA 6 15 Figure 3 Connecting the BENNING TA 6 16 5190 04 2021 en BENNING TA 6 4...

Page 5: ...List of tables List of tables Table 1 History 7 Table 2 Symbols on the device 10 Table 3 Symbols used in the operating manual 10 Table 4 Technical data 18 5190 04 2021 en BENNING TA 6 5...

Page 6: ...L3 N L1 L2 L2 L3 L3 L1 RCD testing Phase sequence test voltage and frequency measurements Further information http tms benning de ta6 On the Internet you will find the following additional information...

Page 7: ...opment Benning reserves the right to make changes to the device s design configuration and technology The information in this operating manual corresponds to the state of technical knowledge at the ti...

Page 8: ...hnical questions on handling the device Phone 49 2871 93 555 Fax 49 2871 93 6555 E Mail helpdesk benning de Internet www benning de Returns management Easily and conveniently use the BENNING returns p...

Page 9: ...ion to this warning irreversible or deadly injuries will occur WARNING Hazard to humans If you do not pay attention to this warning irreversible or deadly injuries could occur CAUTION Minor hazard to...

Page 10: ...low voltage mains installation The device complies with EU directives At the end of product life dispose of the unserviceable device via appropriate collecting facilities provided in your community T...

Page 11: ...ng the warranty period a decision about a warranty claim can only be made once the findings are available Direct any questions to Technical Support page 8 Using the device Please observe the following...

Page 12: ...ws visible damage or is damp wet The device does not work properly in compliance with regulations e g errors during measurements The device shows recognisable consequences of prolonged storage under i...

Page 13: ...livery 2 5 Special types of risks 5190 04 2021 en BENNING TA 6 13 3 Scope of delivery The scope of delivery of the device includes the following components 1 x BENNING TA 6 measuring adapter 1 x opera...

Page 14: ...190 04 2021 en BENNING TA 6 14 4 Device description 4 1 Device structure 1 3 4 5 6 2 Figure 1 BENNING TA 6 device structure 1 Housing 2 Rotary switch 3 Test cable 4 16 A CEE plug 3P N PE 400 V 50 Hz 5...

Page 15: ...frequency measurements Switch positions 1 2 3 4 5 Figure 2 Switch positions of the BENNING TA 6 1 Rotary switch 2 4 switch positions for insulating resistance measurement RISO L1 PE L2 PE L3 PE N PE 3...

Page 16: ...only at test objects which are free of voltage 1 2 3 Figure 3 Connecting the BENNING TA 6 1 BENNING installation tester 2 BENNING TA 6 3 Test object Procedure 1 Connect the connecting plug of the devi...

Page 17: ...t get damaged Do not open the device Please contact your specialty retailer or the returns management page 8 for any repairs 6 1 Cleaning the device Clean the device regularly and as the need arises R...

Page 18: ...objects 2nd digit 0 no protection against water Overvoltage category CAT II 300 V to earth Housing dimensions length x width x height 145 mm x 85 mm x 70 mm Length of test cable 1 5 m Weight 0 5 kg O...

Page 19: ...ection 6 1 Cleaning the device 5190 04 2021 en BENNING TA 6 19 8 Disposal and environmental protection At the end of product life dispose of the unserviceable device via appropriate collecting facilit...

Page 20: ...Maintenance 17 Manufacturer 2 N Non discrimination 2 P Purpose of the operating manual 6 R Return address 8 Returns management 8 S Scope of delivery 13 Securing 12 Service Support Technical support 8...

Page 21: ...5190 04 2021 en BENNING TA 6 21...

Page 22: ...nting Subject to technical changes No liability accepted for printing errors BENNING Elektrotechnik und Elektronik GmbH Co KG M nsterstra e 135 137 D 46397 Bocholt Phone 49 2871 93 0 Fax 49 2871 93 42...

Reviews: