Benjamin Heating products TRAVELER BPTCA515 Owner'S Manual Download Page 2

6.  MAINTAINING YOUR COMPRESSOR

IMPORTANT

: Before doing any maintenance on your compressor make sure the unit is not pressurized by opening the release valve and 

disconnect from any source of power.

 

Use only a dampened cloth to clean exterior of compressor.

 

 Avoid using any detergent or solvents, which might contain chemical that could damage plastic components and/or painted 

surfaces of the compressor.

 

All other services should be performed by an Authorized Service Personnel.

A.  Cotton Filter

It is recommended that you change the cotton air filter after the earlier of three (3) months, 50 hours of use or  if they become deformed or 

extremely dirty (filters sold separately).

IMPORTANT

: Before using and/or storing the compressor, inspect its cotton filter in the oil/water separator as follows:

1. 

Remove the filter housing from the top of the compressor.

2. 

Using snap ring pliers, unscrew the brass filter cover and remove the cotton filter.

3. 

Squeeze the cotton filter dry to remove excessive amount of moisture.

4. 

Replace cotton filters if it become deformed or extremely dirty (filter sold separately).

B.  Lubricating the compressor

This compressor is lubricated using solid lubricants. MP-3 or Multipurpose Lithium grease is the 

recommended solid lubricant. It is recommended that you do this once a year.

1. 

Remove the cover from the compressor.

2. 

Locate the two  lubrication port on the right side  of the compressor (Fig. 8).

3. 

Remove rubber plugs and add 1oz of MP-3 grease to each lubrication port.

4. 

Re-install rubber plugs into housing and the cover on the compressor.

7.  EXPLODED VIEW OF PARTS

Cleaning or replacing these parts can solve most of the compression problems. Spare parts, included with the compressor.

1

6

5

9

12

5

2

7

10

3

3

4

8

5

5

11

5

1. 

Black Plastic Ball

2. 

Black O-Ring (D46*2)

3. 

Green O-Ring (D12*2)

4. 

Low Pressure Check Valve

5. 

White Spacer

6. 

Middle Pressure Check-Valve Set

7. 

High Pressure Check Valve

8. 

Green O-Ring(D14*2)

9. 

Green O-Ring (D16*2)

10. 

Cotton Filter

11. 

POM Black Spacer

12. 

Copper Burst Disc

7

8

9

10

11

12

1

4

2

3

5

6

8.  LOAD INDICATOR ERROR CODES

A.  Issue – L

1.  Resolution –

 The supply voltage is lower than 10.8v.

B.  Issue – H1

1.  Resolution –

 The supply voltage is higher than 14V.

C.  Issue – H2

1.  Resolution –

 The current is higher than 29 when the machine is working.

D.  Issue – H3

1.  Resolution –

 The temperature is above 85 when the machine is working.

9.  TROUBLESHOOTING

A.  Issue – Air Compressor will not start

1.  Resolution –

 Check to make sure the air compressor is plugged into an active electrical outlet or charged 12V battery.

2.  Resolution –

 Check to make sure the DC AC toggle switch is set on the proper setting for which you plan to power the compressor.

3.  Resolution –

 Check to see if the fuse failed.

B.  Issue – Air Compressor is not building pressure

1.  Resolution –

 Make sure both release valve and moisture release valve is closed. It should be hand tightened.

2.  Resolution –

 Check any noticeable air leaks around the fill hose and or fill adapters.

3.  Resolution –

 Check to see if the burst disk failed.

C.  Issue – Air Compressor shuts off before reaching desired pressure

1.  Resolution –

 Make sure the Output Pressure (Auto Shut Off) is set properly.

2.  Resolution –

 Make sure the converter is switched to the right output voltage of the plug.

D.  Issue – Burst Disc Failure

1.  Resolution –

 Should the Burst Disc (Safety Valve) fail during use of the compressor, shut off the compressor. Open the Release 

Valve (Bleed Screw) to vent the remaining air from the compressor. Remove the Burst Disc retention screw to verify the Burst Disc 

has failed (there will be a hole in it). Remove the failed Burst Disc from the compressor. Additional Burst Discs are in the bag of spare 

parts that comes with the compressor. Install a new Burst Disc and re-insert the Burst Disc retention screw by turning it clockwise.

SPECIFICATIONS
Working Voltage

Direct Current 12V-15V

Motor Power

DC12V 350W or AC 110V or 220V 450W

Working Pressure

Up to 4,500 PSI

Application Range

Airgun/Paintball Cylinders less than .6L (600cc) 

LIMITED ONE YEAR WARRANTY

This product is warranted to be free of defects in materials and workmanship for 1 year. Buyer should retain the original sales receipt as 

record of date of purchase. This warranty does not cover adaptors, filters, attachments or other accessories. In the event of a defect under this 

warranty, Crosman will, at its option, repair or replace the product; provided, however, its inspection indicates that an original defect exists. 

Crosman reserves the right to replace any product which is no longer available with a product of comparable value and function. If Crosman 

determines the repair is not covered under the warranty guidelines, there could be a charge to you for the repair.

WHAT IS COVERED

1. 

Parts and Repair of any factory defect of material or workmanship.

2. 

Transportation charges to consumer for the repaired product and/or replacement product.

WHAT IS NOT COVERED

1. 

Transportation charges to the Authorized Service Personnel for defective product.

2. 

Normal wear and tear from regular use.

3. 

Damaged parts as a result from misuse, neglect or tampering.

4. 

Damage caused by abuse, modification or failure to perform normal maintenance – see Owner’s Manual.

5. 

Improper installation or maintenance performed by someone other than an Authorized service personnel.

6. 

Any other expense.

THIS LIMITED WARRANTY DOES NOT INCLUDE CONSEQUENTIAL DAMAGES, INCIDENTAL DAMAGES OR INCIDENTAL EXPENSES, INCLUDING 

DAMAGE TO PROPERTY OR ANY OTHER EXPENSE. CROSMAN DISCLAIMS ANY IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTIES OF 

MERCHANTABILITY AND FITNESS. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, 

OR ALLOW LIMITATIONS ON IMPLIED WARRANTIES SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. TO THE EXTENT ANY 

PROVISION OF THIS WARRANTY IS PROHIBITED BY FEDERAL, STATE OR MUNICIPAL LAW, IT SHALL NOT BE APPLICABLE. THIS WARRANTY GIVES 

YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS, WHICH VARY FROM STATE TO STATE AND COUNTRY TO COUNTRY.

   STOP – BEFORE YOU RETURN THIS PRODUCT TO THE STORE

Save on gas and avoid the trip back to the store. Contact our Customer Service/Technical Support representatives for information and 

trouble-shooting help. Call 1-800-7AIRGUN (1-800-724-7486) or find answers to frequently asked questions at www.crosman.com.

WARRANTY CLAIM AND REPAIR SERVICE

If your compressor needs repair - DO NOT ATTEMPT TO DISASSEMBLE IT! Your compressor requires special tools and fixtures to repair it. Any 

disassembly or modification not performed by Authorized Service Personnel will void the warranty.

U.S. Customers -

 Contact Crosman Customer Service at 800-724-7486 or e-mail us via www.crosman.com. You will be instructed where and 

how to send your compressor in for repair under warranty.

Crosman Corporation

Attn: Warranty Dept.

7629 Route 5 & 20

Bloomfield, NY 14469

Include with your product a copy of your receipt and a brief description of the problem. Be sure to indicate your name, mailing address, e-mail 

address and telephone number. We recommend you use a method of shipping that provides you with a tracking number and insurance 

options. Crosman is not liable for any damaged, lost or stolen merchandise during shipping.

Canadian Customers -

 Contact the Gravel Agency, in Quebec at 866-662-4869.

Outside U.S. Customers -

 Please contact your point of purchase dealer/distributor. If you do not know your dealer/distributor, contact our 

International Dept. for assistance at 585-657-6161 or e-mail us via www.crosman.com.
Crosman, Traveler and Benjamin are trademarks of Crosman Corporation.

© 2021 Crosman Corporation  

06-21 OM

Fig. 8

Fig. 8

Reviews: