Beninca SA02M Operating Instructions Manual Download Page 5

7

protection will intervene after this time has elapsed. (Add about 4 sec. to the actual stroke time of the 
automation). Adjustment can be from a minimum of 1 to a maximum of 125 seconds.

 

The minimum time is obtained by rotating the trimmer completely anticlockwise.

 

Note: TL is read by the control unit only at end of operation. Hence, if the Trimmer position is changed 
to modify the following operation it is necessary to wait for the TL of the previuous movement to elapse, 
otherwise cut power off the unit to reset.

TRAC 

This allows

 

to regulate the delay time after which the second gate leaf starts its closing movement. The 

adjustment ranges from 1 sec. min. to 40 sec. max

 

The minimum time is obtained by turning the trimmer completely anticlockwise.

Programming of the control unit
To erase the remote control codes from memory
To erase the codes from the memory, power the control unit by keeping the PGM programming push-button 
pressed. The flashing light switches on. When the flashing light switches off, the memory is erased.

To store a new remote control code in memory
Press the PGM programming button, SCA will start to flash fast until a new remote control is received and stored 
in memory. If, after pressing the button, SCA is not flashing but the flashing light for 5S switches on, this means 
that memory is full and no more codes can be stored in.

Adjustment of the motor power
A faston connector is provided on the power transformer which allows to adjust the power of motors on 4 dif-
ferent levels. The minimum power is obtained by moving the Faston to120, by moving the Faston to 230 the 
power will be maximum.