PARAMETERS, LOGIC AND SPECIAL FUNCTIONS
In the charts following the single available functions are described in the plant.
PARAMETERS (
PAR
)
MENU
FUNCTION
MIN-MAX-(Default)
MEMO
TCA
Automatic closure time. It is enabled only with “TCA”=ON logic.
At the end of the preset time, the control unit controls a closure operation.
1-240-(40s)
Tped
The stroke time of the gate leaf is adjusted during the partial opening phase controlled
by the pedestrian input.
5-100-(20%)
tsm
Braking is adjusted.
The value is expressed in percentage on the aggregate value of the stroke.
0-100-(20%)
FSTS
The opening and closing speed is adjusted.
20-99-(70)
sldS
Speed during braking is adjusted.
20-99-(50)
PMo
Adjustment of amperometric sensor sensitivity in opening*
1: maximum sensibility - 99**: minimum sensibility
1-99-40%)
PMC
Adjustment of amperometric sensor sensitivity in closing*
1: maximum sensibility - 99**: minim sensibility
1-99-(40%)
TLS
It is activated only with AUX1 or AUX2 parameter preset on value 2.
The activation time of the service light is adjusted.
1-240-(60s)
AUX1
It selects the operating mode of the AUX 1 output:
0: Open gate indicator light. The light is off when the door is closed, flashes with
moving door and is on with open door.
See wire diagram.
1: Second radio channel. The output is controlled by the radio channel of the built-in
receiver (see RADIO Menu).
2: Service light. The contact closes for the time preset with TLS parameter. The
countdown starts at the inception of operation.
3: Area light. The contact closes in the opening phase and remains closed for the
entire TCA time. It opens only with closed door.
See wire diagram, Fig. 2.
0-3-(0)
AUX 2
The same operating options as AUX1 output, but referred to AUX2 terminals. See
connections in Fig. 3.
0-3-(1)
TBR
Stop space is adjusted after reaching the opening and closing limit switch.
1-3-(3)
SPIN
It regulates the reversal space that the leaf runs as consequence a result of the safety
edge action (or triggering of the amperometric sensor).
During the reversal phase any further action of safety edge or photocells is ignored.
This value is expressed in second.
1-4 (2)
* ATTENTION: A wrong formulation of these parameters can be dangerous.
Respect the regulations in force!
** By presetting the value at 99 before carrying out the Autotest, the control unit does perform the calculation of the torque, as
indicated in paragraph "LEARNING OF VALUES", and the amperometric sensor is disabled.
LOGICS (
LOGI
)
MENU
FUNCTION
DEAFULT
MEMO
TCA
Enables or disables automatic closing
On: automatic closing enabled
Off: automatic closing disabled
(ON)
IBL
Enables or disables multi-flat function.
On: multi-flat function enabled. The step-by-step and perdestrian commands have
no effect during the opening phase.
Off: multi-flat function disabled.
(OFF)
IBCA
During the TCA phase, the PP controls are enabled or disabled.
On: PP controls are disabled.
Off: PP controls are enabled.
(OFF)