Technical data 

Absolute limit values 

The following parameters must not be exceeded under any circumstances to prevent damage to the device: 

Parameters 

min. 

max. 

Unit 

Operating voltage 

-0.5 

+63 

Storage temperature 

-40 

+85 

°C 

Ambient temperature during operation 

-20 

+70 

°C 

Voltage at limit switch inputs 

-5 

+63 

Voltage at the relay terminals 

 

30 

Vdc 

 

250 

Vac 

Current per relay contact (X4) 

 

Aeff 

Current at brake relay (X2) 

 

Current at analog output 0..10V 

 

20 

mA 

 

Electrical connection values 

Parameters 

min. 

max. 

Unit 

Operating voltage  

+24 

55 

Power consumption without motors 

 

80 

mA 

12V output max. load 

 

300 

mA 

5V output max. load 

 

200 

mA 

Ambient temperature 

+50 

°C 

Crotch frequency 

200 

kHz 

Delay time automatic current reduction 

0.5 

0.7 

Threshold over temperature 

70 

85 

°C 

Current control accuracy 

-10 

+10 

Cable cross section for terminals Supply 

0.5 

2.5 

mm² 

Cable cross section for terminals Motor 

0.22 

mm² 

Number of microsteps per full step 

10 

Microsteps/revolution for standard motor

1

 

1000 

2000 

 

                                                           
1  Standard motor: 1.8°/full step, 200 full steps/revolution 

Summary of Contents for TripleBeast

Page 1: ...still required The effort for mounting wiring and the possibilities for errors are thus reduced to a minimum The Triple BEAST offers all the advantages of the individual BEAST power amplifier at extre...

Page 2: ...lutely necessary More detailed selection criteria are listed in the chapter0 3 A PC with Beamicon2 CNC software and a RJ45 network cable patch cable Please note that this version of the Triple BEAST i...

Page 3: ...Signal input 7 Reference switch 4th axis voltage output 12 24V 8 Reference switch 4th axis Signal input Relay outputs 6 pin terminal X4 bottom left No Description 1 230V L Input 2 230V N Input 3 Relay...

Page 4: ...d power supply consisting of transformer rectifier and filter capacitor is also suitable Please note however that the voltage range must be maintained even with mains and load fluctuations usually 10...

Page 5: ...for all axes simultaneously Simultaneous operation of very small and very large motors is therefore not possible Depending on the selected range the fine adjustment can then be carried out separately...

Page 6: ...jumpers These are numbered from right to left with no 12 to 16 and are described further below The LEDs on the upper side indicate the status of the PC interface LEDs Lettering Description 1 green Pow...

Page 7: ...a red plug or X The network interface is galvanically isolated from the PC Power over Ethernet PoE is not supported Reference switch inputs Up to 4 switches or inductive sensors can be connected If th...

Page 8: ...upply ground However this is not a problem with all modern frequency inverters because they have an isolated speed input Care should be taken with old thyristor controllers whose speed input is partia...

Page 9: ...nected to the supply voltage of the power supply X1 5 This is useful if a 24V power supply unit is connected there and the switches used are inductive proximity switches or similar industrial sensors...

Page 10: ...neously as a reference and limit switch The following output signals are available and can be assigned to the logical signals in the software right table Pin Name Signal Description Release Current re...

Page 11: ...purposes only a jumper may be connected between pins 5 and 6 of X2 as an alternative An emergency stop switch is legally required on a machine If these requirements are met you can establish the conne...

Page 12: ...selected if several modules are in the network 4 LED Charge Pump green is not lit a ChargePump signal not assigned or module is not connected b Software not started or running in demo mode 5 LED Drive...

Page 13: ...age at the relay terminals 30 Vdc 250 Vac Current per relay contact X4 8 Aeff Current at brake relay X2 5 A Current at analog output 0 10V 20 mA Electrical connection values Parameters min max Unit Op...

Reviews: