  Version 0.7                                 3 September 2015                                   

www.benext.eu

                                Page 5 of 9 

 
If a SENSOR_MULTILEVEL_GET command is sending without a sensor type (version 1), then the ‘air 
temperature’ (0x01) is reported.

 

 
Class: 0x72 COMMAND_CLASS_MANUFACTURER_SPECIFIC 

This will report information about the manufacturer. This product will contain the manufacturer ID of 

BeNext

Manufacturer ID of 

BeNext

 is 138, the ID of this product is 33. 

 
Class: 0x85 COMMAND_CLASS_ASSOCIATION 

The association command class is used to associate other devices with the 

Heating Control

. The devices that 

are associated will receive unsolicited reports. 
 
The 

Heating Control

 has one association group. 

 
Group 1 

Maximum supported nodes: 1 
 

Every unsolicited report will be sent to the nodes in this group.  

 
Class: 0x43 COMMAND_CLASS_THERMOSTAT_SETPOINT 

This command class has two purposes. The first one is to set the reference temperature for the schedule set in 
with the CLIMATE_CONTROL_SCHEDULE. 
 
The second one is to activate a temperature with the THERMOSTAT_MODE_SET or the basic command class. 
The Heating Control supports two set point types: 

0x01: Heating 

0x0B: Energy Save heating 

 
Other set point types will be ignored by application. 

 

 
Class: 0x46 COMMAND_CLASS_CLIMATE_CONTROL_SCHEDULE 
 

Change the temperature set point within a wake up notification. 
Send a temperature offset (compared to the thermostat set point) with the override set command when the 

Heating Control

 sends a wake up notification.  

BYTE 1:  

COMMAND_CLASS_CLIMATE_CONTROL_SCHEDULE 

BYTE 2:  

SCHEDULE_OVERRIDE_SET 

BYTE 3:  

Override type 

BYTE 4:  

Override state 

The override type is the 0x01: Temporary override and is changed when the schedule reached a new switch 
point.  
The override type is the 0x02: Permanent override and is changed when a new SCHEDULE_OVERRRIDE_SET is 
send to the 

Heating Control

 
The override state is the value offset (compared to the thermostat set point) * 0.1 °C. 
 

Summary of Contents for Heating Control EU

Page 1: ...on level or water temperature Mounting Place the Heating Control unit between your thermostat and your boiler you need both opentherm Example 1 Open your boiler and lookup if it supports OpenTherm pro...

Page 2: ...u are in doubt about the proper operation take the product back to the place of purchase Do not clean the product with any liquid Indoor use only Technical details Product dimensions length x width x...

Page 3: ...ands and perform actions based on the command A routing slave can route Z Wave messages to other nodes in the network This device is always awake and does not go to sleep mode because it is an AC powe...

Page 4: ...d The chance is still present that it still works as intended Only we can t guarantee it In case your thermostat boiler is not listed but still works with the Heating Control we would appreciate it if...

Page 5: ...o set the reference temperature for the schedule set in with the CLIMATE_CONTROL_SCHEDULE The second one is to activate a temperature with the THERMOSTAT_MODE_SET or the basic command class The Heatin...

Page 6: ...using Z Wave class 0x70 COMMAND_CLASS_CONFIGURATION_V1 Configure parameters 1 Set to default Description Set all configuration values to default values factory settings Read more in chapter configura...

Page 7: ...s Fout 203 send cfg value again Default 0x00 disabled Param1 0x00 No special 0x01 Remeha Celcia 20 0x02 Honeywell rounded temperatures Param2 3 4 Not used Size 1 byte 7 Status auto report Description...

Page 8: ...ports a configuration reset function Configuration reset means that all configuration values are defaulted This function can be activated by sending a configuration set frame CONFIGURATION_SET Paramet...

Page 9: ...y Toon Remeha c Mix Regelmodule 2x Remeha iSense Remeha Celcia 20 Remeha iSense Siemens QAA73 Termet Regulator OPEN THERM typ CR 11011 WKZ0 624000000 Theben RAM 850 top2 Viessmann Vitovent 300 control...

Reviews: