Version 0.7 3 September 2015
www.benext.eu
Page 5 of 9
If a SENSOR_MULTILEVEL_GET command is sending without a sensor type (version 1), then the ‘air
temperature’ (0x01) is reported.
Class: 0x72 COMMAND_CLASS_MANUFACTURER_SPECIFIC
This will report information about the manufacturer. This product will contain the manufacturer ID of
BeNext
.
Manufacturer ID of
BeNext
is 138, the ID of this product is 33.
Class: 0x85 COMMAND_CLASS_ASSOCIATION
The association command class is used to associate other devices with the
Heating Control
. The devices that
are associated will receive unsolicited reports.
The
Heating Control
has one association group.
Group 1
Maximum supported nodes: 1
Every unsolicited report will be sent to the nodes in this group.
Class: 0x43 COMMAND_CLASS_THERMOSTAT_SETPOINT
This command class has two purposes. The first one is to set the reference temperature for the schedule set in
with the CLIMATE_CONTROL_SCHEDULE.
The second one is to activate a temperature with the THERMOSTAT_MODE_SET or the basic command class.
The Heating Control supports two set point types:
-
0x01: Heating
-
0x0B: Energy Save heating
Other set point types will be ignored by application.
Class: 0x46 COMMAND_CLASS_CLIMATE_CONTROL_SCHEDULE
Change the temperature set point within a wake up notification.
Send a temperature offset (compared to the thermostat set point) with the override set command when the
Heating Control
sends a wake up notification.
BYTE 1:
COMMAND_CLASS_CLIMATE_CONTROL_SCHEDULE
BYTE 2:
SCHEDULE_OVERRIDE_SET
BYTE 3:
Override type
BYTE 4:
Override state
The override type is the 0x01: Temporary override and is changed when the schedule reached a new switch
point.
The override type is the 0x02: Permanent override and is changed when a new SCHEDULE_OVERRRIDE_SET is
send to the
Heating Control
.
The override state is the value offset (compared to the thermostat set point) * 0.1 °C.