Quickstart:

 Heating Control EU 

Technical specifications 

Normal operating voltage 

5 Volt (mini-USB connector) 

Frequency range 

868.42 MHz 

Wireless range 

30 ~ 50meter line of sight. 

Protocols supported 

OpenTherm only! 

Basic operations 

-

 

Override or request the temperature set point of your thermostat 

-

 

Control the heating in your house with Lifestyles and Rules 

-

 

An intern schedule which will change the temperature set points on a preconfigured timetable 

-

 

Reporting thermostat related values like room temperature 

-

 

Reporting boiler related values like boiler pressure, modulation level or water temperature 

Mounting 

-

 

Place the 

Heating Control

 unit between your thermostat and your boiler. (you need both opentherm) 

Example: 
1.

 

Open your boiler and lookup if it supports OpenTherm protocol. 

2.

 

Remove the wires of your thermostat and place them into the 

Heating Control

 unit. 

3.

 

Insert the 

Heating Control

 wires into the boiler connector. 

4.

 

Now place the USB power. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

Include or exclude in Z-Wave network 

1

 

1.

 

Press and hold the push button for 2 seconds and release to start the inclusion or exclude process. 

2.

 

When classic inclusion failed, the product will start Network Wide Inclusion automatically. 
 

  

 

                                                           

1

 Make sure your Z-Wave controller is in the correct operation mode (include or exclude). 

Disconnect

 

thermostat wires 

And 

connect

 here the 

thermostat wires 

Connect these 

wires to the boiler 

Connect the USB 

power 

Summary of Contents for Heating Control EU

Page 1: ...on level or water temperature Mounting Place the Heating Control unit between your thermostat and your boiler you need both opentherm Example 1 Open your boiler and lookup if it supports OpenTherm pro...

Page 2: ...u are in doubt about the proper operation take the product back to the place of purchase Do not clean the product with any liquid Indoor use only Technical details Product dimensions length x width x...

Page 3: ...ands and perform actions based on the command A routing slave can route Z Wave messages to other nodes in the network This device is always awake and does not go to sleep mode because it is an AC powe...

Page 4: ...d The chance is still present that it still works as intended Only we can t guarantee it In case your thermostat boiler is not listed but still works with the Heating Control we would appreciate it if...

Page 5: ...o set the reference temperature for the schedule set in with the CLIMATE_CONTROL_SCHEDULE The second one is to activate a temperature with the THERMOSTAT_MODE_SET or the basic command class The Heatin...

Page 6: ...using Z Wave class 0x70 COMMAND_CLASS_CONFIGURATION_V1 Configure parameters 1 Set to default Description Set all configuration values to default values factory settings Read more in chapter configura...

Page 7: ...s Fout 203 send cfg value again Default 0x00 disabled Param1 0x00 No special 0x01 Remeha Celcia 20 0x02 Honeywell rounded temperatures Param2 3 4 Not used Size 1 byte 7 Status auto report Description...

Page 8: ...ports a configuration reset function Configuration reset means that all configuration values are defaulted This function can be activated by sending a configuration set frame CONFIGURATION_SET Paramet...

Page 9: ...y Toon Remeha c Mix Regelmodule 2x Remeha iSense Remeha Celcia 20 Remeha iSense Siemens QAA73 Termet Regulator OPEN THERM typ CR 11011 WKZ0 624000000 Theben RAM 850 top2 Viessmann Vitovent 300 control...

Reviews: