VHDI-0050M
V00150213-U(1)
5. Maintenance
Storage conditions
Products storage temperature should be -20°C~60°C. For long time storage requirement,
please use original carbon boxes, and avoid from high humid, acid base or dusty place.
Maintenance
Warning
To ensure your safety, place choose original adapters. And provide stable AC input according
to this manual.
6. Trouble shooting
Normal problems
a) No output on display terminals
Check transmitter and receiver power first. And then check if transmitter unit video
indicator is light. If it is not, check video source please. If it is, check receiver unit video
indicator. If receiver video indicator is not light, check CAT5e/6 cable please.
If length of cable is longer than maximum distance, the system is not workable.
Refer to manual parameters segment to get more details of distance. If receiver video
indicator is light, check HDMI cable and display terminal please.
b) Remote IR is not workable
Check transmitter and receiver power fist. Ensure both TX and RX power and video
indicators are light. And then check CAT5e/6 cable please. Check if IR blaster unit
connects to extender IR out port, and close to controlled device. And check if remote
controller faces to IR receiver.