15.1.1999
3GP_60GB
8
Product: TGP-60-EU (Vega) / Local Service Mode
4.4.3.1 Tuning
Connect the GSM tester to the phone and select item "Tuning-TX power" from the
menu. First adjust the minimum power level to the specified value and then the max-
imum power level.
Now two pairs of power control/output power values are known. From this informa-
tion, the tuning software is able to create an approximation for the power control/out-
put power curve of this particular unit and solve the power control value for each of
the remaining nine power levels.
You can adjust the template to match by moving the corner positions and minimum
spectrum by adjusting the rise/fall speed. Usually, the default values for the corner
positions and speed should be correct. However, you should check the spectrum
due switching on the two highest power levels and the power template on the two
smallest power levels, especially the rising edge position. If any of these fail, you
should check all levels.
4.4.4 RX RSSI
A GSM mobile must be able to report the correct receiver input signal level (RXL)
and quality (RXQ) to the base station. The reported RX level is calculated from the
RF gain control value in the AGC circuit and I/Q demodulator input level, and cor-
rected with calibration values individual to each phone.
4.4.4.1 Tuning
Connect the GSM tester or RF signal generator to the phone and select item "Tun-
ing-RX RSSI" from the menu. Adjust the generator according to the software direc-
tions.
The RX level measurement is performed and the difference between measured and
actual value is calculated.
Measurement is repeated using different signal levels. After all measurements are
completed, the calibration table is calculated and stored on EEPROM.
4.4.5 A/D converter calibration
Remove the battery and connect a multimeter to the battery connector pins behind
the phone. Adjust the external power supply voltage until the voltage of the battery
pins is 5.0 +/- 0.01 volts.
The phone should be at room temperature (25 +/-5 degrees Celsius) for correct tem-
perature calibration.
Select item "Tuning-A/D converter" from the menu. The input values of the battery
voltage and temperature measurement channels are read and stored on EEPROM.
Summary of Contents for TGP-65-EU iO
Page 1: ...15 1 1999 GP_60UGB TOC 1 Product TGP 60 EU Vega SERVICE MANUAL BENEFON VEGA TGP 60 EU ...
Page 10: ...15 1 1999 2GP_60GB 6 Product TGP 60 EU Vega ...
Page 12: ...15 1 1999 2GP_60GB 8 Product TGP 60 EU Vega ...
Page 13: ...15 1 1999 2GP_60GB 9 Product TGP 60 EU Vega BeneWin BeneWin ...
Page 14: ...25 01 1999 1USER_GB 1 Product TGP 65 EU io 2 0 OWNER S MANUAL ...
Page 39: ...15 1 1999 4a1800gb 13 Product TGP 60 EU Vega ...
Page 40: ...15 1 1999 4a1800gb 14 Product TGP 60 EU Vega ...
Page 41: ...15 1 1999 4a1800gb 15 Product TGP 60 EU Vega ...
Page 42: ...15 1 1999 4a1800gb 16 Product TGP 60 EU Vega ...
Page 43: ...15 1 1999 4a1800gb 17 Product TGP 60 EU Vega ...
Page 44: ...15 1 1999 4a1800gb 18 Product TGP 60 EU Vega ...
Page 45: ...15 1 1999 4a1800gb 19 Product TGP 60 EU Vega ...
Page 46: ...15 1 1999 4a1800gb 20 Product TGP 60 EU Vega ...
Page 56: ...15 1 1999 4y1800gb 30 Product TGP 60 EU Vega OY1800 The Top Side Layout PY1800A3 ...
Page 57: ...15 1 1999 4y1800gb 31 Product TGP 60 EU Vega OY1800 The Bottom Side Layout PY1800A3 ...
Page 58: ...15 1 1999 4y1800gb 32 Product TGP 60 EU Vega OY1800 ...
Page 59: ...15 1 1999 4y1800gb 33 Product TGP 60 EU Vega OY1800 oy180a5 sch 2 Wed Sep 02 08 25 38 1998 ...
Page 60: ...15 1 1999 4y1800gb 34 Product TGP 60 EU Vega OY1800 ...
Page 61: ...15 1 1999 4y1800gb 35 Product TGP 60 EU Vega OY1800 ...
Page 62: ...15 1 1999 7GP_60GB 36 Product TGP 60 EU Vega 5 5 MECHANICS ...