Dear Customer,

Your Buderus 

600 Series 

wall-mounted condensing gas 

boiler has been designed and built in accordance with 
state-of-the-art technological standards and the 
recognised safety rules. Special focus has been placed 
on operator convenience in this respect.
Carefully read the safety instructions and operating 
manual to ensure safe, economic and ecologically 
beneficial use of the unit.
Due to the high efficiency of the boiler a plume of water 
vapour may form at the terminal during operation. 
This is normal.

1

Safety precautions

A

DANGER!
If you smell gas

:

1. No naked flames ! Do not smoke !
2. Avoid sparks ! 

Do not operate electrical switches.
Do not use the telephone, plug-in devices of 
any kind or the doorbell!

3. Shut off the main gas supply!
4. Open windows and doors!
5. Warn building occupants and evacuate the

building!

6. Call TRANSCO (under 'GAS' in the telephone 

directory) from outside the building!

I

NOTE

In the event of any other type of incident, shut off 
the main gas supply and electric supply to the 
appliance and seek assistance from a CORGI 
registered engineer. 

2

Installation area / boiler 
room

A

DANGER!

The air intake and outlet openings must not be 
reduced in size or closed.

A

DANGER!

Do not store or use inflammable materials or 
liquids near the heating boiler.

I

NOTE

To prevent the boiler from being damaged, care 
must be taken not to contaminate the 
combustion air with halogenated hydrocarbons 
(e. g. contained in aerosol sprays, solvents, 
detergents, paints, and adhesives), or with high 
quantities of dust. The room in which the boiler 
is installed must be frost-proof and be well 
ventilated.

3

Working in the heating 
system

A

DANGER !

Only a CORGI registered Engineer is to be 
entrusted with the installation of this boiler, the 
gas supply and the flue connection. 
Commissioning, Servicing and any Repairs 
must be carried out by a competent person i.e.: 
a CORGI Registered Engineer. 
All CORGI Registered Installers carry a CORGI 
identification card and have a registration 
number. Both should be recorded in your boiler 
logbook. You can check your installer/Engineer 
is registered by telephoning 01256 372300 or by 
writing to:
CORGI, 1 Elmwood, Chineham Business Park, 
Crockford Lane, Basingstoke. RG24 8WG

4

Functions of the system 
and operating instructions

The installer should familiarize the user with the 
functions and operation of the heating system and 
ensure that a complete set of technical documentation is 
supplied.

5

Maintenance intervals

For optimum, long-term reliable functioning of the 
heating boiler, and in order to be able to claim under the 
terms of the manufacturer's warranty, the heating boiler 
must be inspected and maintained at least once a year 
(under normal operating conditions) by an officially 
recognized installation and service engineer. The term 
"normal operating conditions" means that the heating 
boiler is used to provide central heating and/or hot water 
to no more than one single-family dwelling.

In all other cases, the heating boiler must be inspected 
and maintained by an officially recognised installation 
service engineer every 2,500 burner operating hours. 

Summary of Contents for Buderus 600 - 28C

Page 1: ...7212 8000 02 2006 GB IE EN For the user Please read thoroughly before operating the unit Users manual Gas wall hung Boiler condensing Buderus 600 28C...

Page 2: ...lding Regulations current I E E Wiring Regulations and the relevant British Standard Codes of Practice The device may only be used in combination with the units accessories and spare parts listed in t...

Page 3: ...e combustion air with halogenated hydrocarbons e g contained in aerosol sprays solvents detergents paints and adhesives or with high quantities of dust The room in which the boiler is installed must b...

Page 4: ...ntil the system pressure P1 1 appears in the display Optimum filling pressure is 1 5 bar 6 1 2 Topping up the heating system A WARNING The wall mounted condensing gas boiler must not be activated at t...

Page 5: ...Turn the knob with the tap symbol fig 5 item 1 to the desired temperature for your domestic hot water see table 2 Set the knob to Eco when the boiler is situated in an area with hard water to prevent...

Page 6: ...un over time The range is 0 min to 60 min F 0 F60 and 24 hours F1d z Set the pump run over time to F1d fig 6 item 4 when there is a frost hazard z Confirm the selection by pressing the service button...

Page 7: ...7 item 1 and leave the gas service valve open fig 8 item 2 z Adjust room temperature to minimum or frost protection setting at regulating device or on remote control unit I NOTE If you intend to shut...

Page 8: ...ww buderus domestic co uk Buderus is a trading name of BBT Thermotechnology UK Ltd Customer Services Technical Product Support Sales Returns Spares Tel 0870 421 5933 Tel 0870 421 5944 Tel 01905 752 64...

Reviews: