16
5. GENERATOR USE
WARNING!
Before using the generator, consult a local electrician and local
electrical codes to determine grounding requirements for your
intended use. This generator is floating neutral.
Do not connect to the building’s electrical system. Doing so may
result in electrical shocks and fire.
To prolong engine life, do not exceed the rated running wattage.
Do not connect an extension to the exhaust pipe.
When an extension cable is required, be sure to use a tough
rubber sheathed flexible cable (according to IEC245 or equivalent
standards). The maximum length of the extension cable: 196
feet (60 meters) for cable of 15.5 gauge
(1.5mm
2
); 328 feet (100
meters) for cable of 13.25 gauge (2.5mm
2
).
Keep away from other electric cables or wires.
5.1 READY TO USE, OVERLOAD, AND OIL ALERT INDICATOR
Light (Solid)
Description
Green
Ready to Use Indicator
ON
Indicates normal operation
OFF
Indicates a problem or unit is off
Red
Overload Indicator
ON
Indicates overload or problem with
connected appliances, disconnect any
appliances.
OFF
Indicates normal operation
Red
Low Oil Indicator
ON
Indicates insufficient oil in the
crankcase
OFF
Indicates normal operation
Ready to Use
Pret a utiliser
Low Oil
Huile bas
Overload
Surcharge
BG
i-SERIES
Summary of Contents for BG4000i
Page 1: ...BG4000i USER MANUAL TM...
Page 4: ...THIS PRODUCT MEETS ALL CERTIFICATION REQUIREMENTS FROM...
Page 42: ...35 11 WIRING DIAGRAM TM...
Page 50: ...TM BG4000i TM MC TM MC...
Page 51: ...BG4000i GUIDE DE L UTILISATEUR MC...
Page 54: ...CET ARTICLE R POND TOUS LES REQUIS DE CERTIFICATION DE...
Page 93: ...36 11 DIAGRAMME DU C BLAGE BG i SERIES...
Page 102: ...MC BG4000i TM MC TM MC...