benchmarkwireline.com
P. O. BOX 850
Fax: 281.342.4848
Phone: 281.342.6415
Simonton,Texas 77476
36220 FM 1093
AMS4A051 Hoistman's Panel Specification May 2007
Page 2 of 10
1.2 FEATURES
--
Digital displays for depth, line speed, and tension
--
Analog incremental tension meter, 4 inch (108 mm) dia., 270 degree.
--
Incremental tension zero push switch.
--
Excessive tension alarm setting allows operator to set tension alarm to a
predetermined value. Contact closure is provided for winch shutdown.
--
Zero Depth button - sets depth to 0. Depressing button again resets
depth to previous setting. Only works when line speed is zero
--
Approaching surface alarm
--
Depth adjust up or down switches. Only works when winch is stopped
--
Load cell zero & calibrate controls. Only works when there is no load on
cable.
--
Depth & tension saved in non-volatile memory at power loss
--
Outputs for Tension and Encoder to interface to an acquisition system.
--
RS232 Interface for additional control and data outputs.
--
Can be set to display either English or Metric units.