BSH6000 Operation manual

                                                Chapter 3 Basic Instructions 

  4 

Keypads 

B

Block A

Block B

Temp

.

Time

h:m

Temp

.

Time

h:m

Block A

Block B

Block A

TM

B

Block A

Block B

Temp

.

Time

h:m

Temp

.

Time

h:m

Block A

Block B

Temp

.

Time

h:m

Temp

.

Time

h:m

Temp

.

Time

h:m

Temp

.

Time

h:m

Block A

Block A

Block B

Block B

Block A

TM

  Display 

 
 

Mode 

Start 

 

Start/Stop key. After the temperature and time setting is selected, 
press this key to start the timer.    This key can also be pressed to 
stop the timer.   

Down  key:  Used  in  both  time  and  temperature  mode  to 
decrease the setting.

The 

“Mode” 

but

t

on 

i

used 

t

t

oggl

bet

ween 

t

he 

t

i

me 

and temperature setting.

Up  key:  Used  in  both  the  time  and  temperature  mode  to 
increase the setting.

Stop

DOMINIQUE DUTSCHER SAS

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for Iso-Block BSH6000

Page 1: ...Operation Manual BSH6000 Iso Block Dry Bath Incubator D O M I N I Q U E D U T S C H E R S A S All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...OVERVIEW 3 STRUCTURE OVERVIEW 3 KEYPADS 4 DISPLAY 4 CHAPTER 4 OPERATION 5 1 TEMPERATURE AND TIME SETTING 5 2 ADVANCED TIMER SETTING ERROR BOOKMARK NOT DEFINED TEMPERATURE CALIBRATION 7 CHAPTER 5 FAIL...

Page 3: ...he electrophoresis blood serum coagulation and a variety of laboratory procedures Features Large digital display of time and temperature Extremely accurate temperature control up to 105 C Built in ove...

Page 4: ...60Hz Technical Data Item No BSH6000 Temperature range Ambient Room Temp 5 C 105 C Timer Max 99hr 59min Temperature accuracy 0 1 C Temperature uniformity 0 2 C Heating time 20 105 C 20min Block Materia...

Page 5: ...ructure keypads and key functions of the instrument as well as preparatory work prior to initial operation Structure overview Power supply Fuse On Off button B block Chamber B Block Display Transparen...

Page 6: ...Start Start Stop key After the temperature and time setting is selected press this key to start the timer This key can also be pressed to stop the timer Down key Used in both time and temperature mode...

Page 7: ...ng The example shows an actual temperature of 28 5 C and 35 minutes remaining c To adjust the set temperature press or keys until the desired temperature Ex 55 5 is showing on the display After 5 seco...

Page 8: ...be adjusted so that the heater will shut down once t i meh a se x p i r e d T oa d j u s t t h ea d v a n c e dt i me rs e t t i n gp r e st h e Mo d e k e ya n d h o l di t f o r 1 0s e c o n d s A f...

Page 9: ...s less than 35 C b Inject olefin oil into one of the cone shaped wells and then put a thermometer thermocouple into this well make sure that the precision of the thermometer should be within 0 1 and t...

Page 10: ...heat to 100 Once 100C is reched and held as constact the decimal begins to flicker After 20 minutes the user can read the actual value from thermometer N o t e s P l e a s er e a dt h ea c t u a l v a...

Page 11: ...atures are quite different Broken sensor or loose contact of the block Contact the supplier 3 O P E n d i s p l a y e d a l a r mi n g b e e p Sensor disconnect Contact the supplier S H O r d i s p l...

Page 12: ...m for reference only PT1 Power HEAT1 HEAT2 PT2 MAIN BOARD FAN2 FAN1 Key andDisplay L PE N HEAT PT100 B lock1 HEAT PT100 B lock2 Fan Fan Switch J3 J12 J1 J8 J6 J10 J11 D O M I N I Q U E D U T S C H E R...

Page 13: ...Memo D O M I N I Q U E D U T S C H E R S A S All manuals and user guides at all guides com...

Reviews: