background image

26

27

INSTALLATION (CONT.)

4.  Water Supply Hose

5.  Installation  

Catch Plate

6.  Bolt & Nut Assembly

7.  Assembly

8.  Flexible Tube

 

Remove existing supply tube 
from fresh tank

 

If your shut off valve is 1/2” 
O.D compression size, use 
supplied 1/2” conversion nut 
as shown above.

 

Slide cone packing and 
washers onto the bolts then 
fasten to securely mount 
bidet seat to toilet.

1.  Slide this product onto the catch 

plate centering the unit with  
the guide arrows on the base.

2.  You will hear a click once this 

product is securely mounted  
to the catch plate.

3.  This product will feel a little  

loose on the toilet bowl. Adjust 
the fit from front to back and  
side to side for balance.

4.  Tighten the nuts on  

both bolts securely.

5.  Check for any water leaks.

 

Place the plate and guides 
over each mounting hole. 
Insert the mounting bolts 
through the plate and 
mounting holes.

 

Connect the flexible tube from 
side of T-Valve to this product, 
Open the Angle Stop valve to  
fill water.

 

Check for any water leaks.

 

Customers should use the  
new hose set provided with  
the product. Do not use used  
set again.

Summary of Contents for bioBidet Bliss BB1700

Page 1: ...OWNER S MANUAL BB1700 ...

Page 2: ...rts 10 Dimensions 11 Remote Control 12 Operation 14 PRODUCT INSTALLATION Installation 25 Unit Separation 29 PRODUCT SETTINGS Maintenance 30 Water Draining 32 Troubleshooting 33 Specifications 34 WARRANTY Warranty 35 Information to the User 38 TABLE OF CONTENTS ...

Page 3: ...the electronic components It is necessary to provide adequate ventilation with a fan open door or open window when bathing GENERAL CAUTIONS 1 Never operate this product if it is not working properly if it has been dropped or damaged or dropped into water Return the product to a service center for examination and repair 2 Do not stand or sit on the seat cover lid It is not designed to support a use...

Page 4: ...t circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current If repair or replacement of the cord or plug is necessary do not connect the grounding wire to either flat blade terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire Check with a qualified electrician or service person i...

Page 5: ...extension cord is not recommended or advised If it is necessary to use an extension cord use only a three prong extension cord one to one and a three slot built in GFCI receptacle that will accept the plug on this product The marked rating of the extension cord should be equal to or greater than the electrical rating of the unit 10amp Consult a qualified electrician or service person if you are no...

Page 6: ...ion LED Window Heated Seat Lid Caution Label Deodorizer Dryer V ent Contr ol Panel for BB 170 0 Feminine W ash Nozzl e Drain button Cone packin g 2 pcs Mounting bolts 2 pcs Catch Plate 1 pcs Nuts 2 pcs Bolt Cas e 2 pcs Water supply hose for electronic bidet Water supply hose T Valve L Valve 1 2 O D Compression Conversion Nut ...

Page 7: ...the massage wash If move button is selected when user is not sitting on the seat it operates nozzle shower function If massage function is selected when the user is not using wash functions it automatically operates was and dry function sequentially If Economy mode is selected seat temperature and water temperature will stay at 89 6 F When user sits on the seat it automatically operates to deoderi...

Page 8: ...ug the power cord into AC120V power outlet Plug the unit into the proper power source and the LED power light will start flashing Wait until the LED power light stops flashing and becomes solid red The water tank will be filled after pushing a wash Posterior Wash Feminine button When the water tank is filling the buzzer Beeps continuously After the water tank is full the buzzer will end with One S...

Page 9: ...x Wash the nozzle spray is more or focused to produce the effect of strong wash to help s timulate bowel movement 2 Press Water pressure High Low button to adjust the water pressure 3 Press Turbo Wash or Vortex Wash continuously for 3 to 5 seconds Automatically the water nozzle comes out and sprays a warm stream of water to the posterior center of the rectum 4 If necessary adjust Position of water...

Page 10: ...initial setting is Off Press button for 3 seconds press the button again for 3 seconds the function is canceled After setting Deodorizer function it is automatically activated when sensing the human body Once used the Deodorizer function automatically stops after 1 minute of operation Deodorizer function stops while dryer is selected After dryer function completes deodorizer automatically is activ...

Page 11: ...ssing the Front or Rear buttons 12 Oscillation Nozzle Movement Function 13 Nozzle Position Adjustment 14 Massage Rhythm Wash When using the Posterior Wash or Feminine Wash functions pressing the MASSAGE button will provide a pulsation spray You may change the pressure of the spray by pressing the High or Low buttons Push the MASSAGE button again and the pulsating action will stop automatically Aut...

Page 12: ...ual temperature setting OTHER ENERGY SAVING TIPS Keep seat cover closed when not in use to prevent heat from being lost Keep temperature set to low Unplug the power cord if you do not plan to use the unit for a long period of time If the MASSAGE function selected when user is not using wash functions it automatically operates wash and dry function sequentially Wash 30 Seconds Dryer 1 minute then a...

Page 13: ...Remove existing supply hose connected to the toilet tank Make sure not to damage the water supply hose Install T Valve at the thread from tank Beeping mode can be enabled or disabled To select or cancel silent mode press and hold down the Stop and Massage remote buttons simultaneously for approximately 3 seconds or until short beeps Single short beep Silent mode has been canceled Double short beep...

Page 14: ...uide arrows on the base 2 You will hear a click once this product is securely mounted to the catch plate 3 This product will feel a little loose on the toilet bowl Adjust the fit from front to back and side to side for balance 4 Tighten the nuts on both bolts securely 5 Check for any water leaks Place the plate and guides over each mounting hole Insert the mounting bolts through the plate and moun...

Page 15: ...Separation Nozzle Combination Separation of Unit From Toilet Bowl 1 Disconnect the power plug 2 Close water supply shut off valve 3 Drain water from bidet seat using drainage as illustrated 4 Remove bidet seat from toilet as illustrated DO NOT TURN UNIT UPSIDE DOWN ...

Page 16: ... and will void the warranty for those Bio Bidet products Bio Bidet will not be responsible for any resulting damages or claims related to the misuse or distribution of non BioBidet Carbon Iodine filters When you clean this product do not use thinner benzene or toilet bowl cleaner It may cause damage to the surface of unit Use a wet cloth when you clean this product Do not spray water directly on t...

Page 17: ...sure to HIGH 2 Clean the strainer The washing water is not warm 1 The water temperature is set to LOW 2 Continuous operation has depleted the supply of warm water 1 Set the water temperature to HIGH 2 Wait about three minutes The seat and dryer is not warm The seat dryer temperature is set to LOW Set the seat dryer temperature to HIGH WATER DRAINING Do not drink the drained water Do not insert fin...

Page 18: ...of products or parts found to be defective provided that such products were properly installed and used in accordance with instructions BBC Innovation LLC reserves the right to make such inspections as may be necessary in order to determine the cause of the defect BBC Innovation LLC will not charge for labor or parts in connection with warranty repairs or replacements BBC Innovation LLC is not res...

Page 19: ...ohibited by applicable law any implied warranties including that of merchantability or fitness for use are expressly limited to the duration this warranty Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitation and exclusion may not apply to you Warning BBC Innovation LLC shall not be r...

Page 20: ... installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determin...

Page 21: ...Thank You Technical Support Customer Service 7900 S Route 31 Crystal Lake IL 60014 T 847 458 2334 U S TOLL FREE 877 339 5214 support biobidet com www biobidet com ...

Reviews: