background image

Operation Manual

BLR-CX

ATTENTION!

When installing BLR-CX, there are the dangers of electric shock! Installation and 
commissioning  are  therefore  to  be  performed  by  a  technician  with  necessary 
qualification. During installation, the relevant regulations setting up of switchboards 
and accident prevention have to be respected.

Equipment with damaged or open housing or terminals shall not be operated at 
mains and are instantly to  unlock.

Process Technique Electronics (Pvt) Ltd

Phone : +91 80 2522 8895, 2522 3736

324 Konena Agrahara

Fax : +91 80 4125 8146

Vimanapura

Email : [email protected]

Bangalore 560 017

http://www.processtechnique.com

Summary of Contents for BLR-CX

Page 1: ...ation the relevant regulations setting up of switchboards and accident prevention have to be respected Equipment with damaged or open housing or terminals shall not be operated at mains and are instan...

Page 2: ...re sensor or temperature switch parallel operation possible upto 14 control exits control exit can be parametered for fan control signal in order contact closed K1 K14 K1 K14 L1 L2 L3 N PE BLR CX TTL...

Page 3: ...ill be damaged by this 4 Disconnect and remove previous pfc relay 5 Mount BLR CX to the control panel with two mounting clips cutout 138x138mm 6 Connect protection earth to PE connection of metal case...

Page 4: ...nection error of CT short link of CT is not removed CT ration is too big compared to real current no current 4 Indication EXPORT kW export if there is no real kW export voltage and current connection...

Page 5: ...NUAL manual mode SETUP Setup of parameters EXPORT kW export NT 2nd target cosj is working ALARM blinking during alarm 1 line cosj menue items 2 line measuring values paramters alarm codes Step indicat...

Page 6: ...er setting of last digit selection of multiplier k kilo or M Mega leading sign I induktive or C capacitive blinking of I or C u storage of setting t abort input o p e n m e n u e move cursor right con...

Page 7: ...t Cmax thi operation hours OPh INFO Step Database size and derating of steps switch cycles steptype chapter INFO Step Database MANUAL Operation Selective switching in and out of control exits chapter...

Page 8: ...step is blinking By using p q following information can be selected Actual Size of Capacitor the value is rated to nominal voltage Derating of Capacitor actual power nominal power in Switch Cycles St...

Page 9: ...Manual Operation cannot be opend in modes LIFO and Combi Filter Referencebook Discharging lock time is also active during manual operation steps are locked a certain time after switching off when vol...

Page 10: ...suring values Pt VT ratio important base for nominal voltage AI Automatic Initialising chapter wrong connection PFC PFC ON OFF HOLD on off freezing of automatic pfc correction CP1 Target cosj 1 base f...

Page 11: ...ng all control exits several times on and off Duration for this is several minutes Not connected exits get steptype Foff Stepsizes are not detected by this function After finished Ai BLR CX has to be...

Page 12: ...rations after a reset of stepdatabase steptype Foff is set automatically Defective Steps When a step is switched 3 times in series without measured size it is detected as defective and it is blocked f...

Page 13: ...eps ALARM SPL Nr Derating of stepsize 70 of original size ALARM stepnumber and code are blinking rotational thi Overtemperature disconnection of steps ALARM OPH max operation hours are reached mainten...

Page 14: ...308 step recogn off NO 309 lock defective steps YES SETUP 200 locked access 310 PFC ON MEASURING 311 Algorithm Bes Fit 1 201 nominal voltage 400V 312 kvar offset 0kvar 202 CT ratio 1 313 asymmetric S...

Page 15: ...HD steps off NO 604 resetAPF 505 Verz THD temp2 60s 605 reset max temperature 506 I 0 freeze PFC NO 606 reset alarm 507 maintenancealarm NO 607 info firmware relaese 508 limit switch cycles 262k 608 c...

Page 16: ...400V AC 2A Fan control using of control exit Interface TTL rear standard optional RS485 Modbus USB Ambient temperature operation 20 V 70 C starage 40 C 85 C Humidity 0 95 without condensation Overvolt...

Reviews: