background image

47

Temperature test, transport and storage information

Beltone Hearing Instruments are subjected to various tests in temperature and damp heating 

cycling between -25 C and +70C according to internal and industry standards.

During transport or storage, the temperature should not exceed the limit values of -20C (68F) to 60C (140F) 
and relative humidity of 90% RH, non condensing (for limited time). The air pressure between 500 and 1100 
hPa (mbar) is appropriate.

International warranty, service and repairs

Beltone provides a warranty on hearing instruments in the event of defects in workmanship or materials, as 
described in applicable warranty documentation

In its service policy, Beltone pledges to secure functionality at least equivalent to the original hearing instru-
ment.

As a signatory to the United Nations Global Compact initiative, Beltone is committed to doing this in line 
with environment-friendly best practices. Hearing instruments therefore, at Beltone’s discretion, may be 
replaced by new products or products manufactured from new or serviceable used parts, or repaired using 
new or refurbished replacement parts.

The warranty period of hearing instruments is designated on your warranty card, which is provided by your 
hearing care professional.

If your Beltone hearing instrument malfunctions, it must be repaired by a qualified technician. Do not at-
tempt to open the case of the hearing instrument since this would invalidate the warranty. If your Beltone 
hearing instrument requires service, please contact your hearing care professional for assistance.

Model

Hearing instrument 

max output (IEC 118-0 OES)

Tinnitus Breaker Pro soundgenerator 

max overall output (IEC 118-0 OES)

PSE64-DRPW

128 dB SPL

90 dB SPL

PSE64-DRPWO

128 dB SPL

90 dB SPL

PSE64-DRW

125 dB SPL

90 dB SPL

PSE64-DRWO

124 dB SPL

90 dB SPL

PSE64-DRSW

123 dB SPL

90 dB SPL

PSE64-DRSWO

123 dB SPL

90 dB SPL

PSE63-DRPW

128 dB SPL

90 dB SPL

PSE63-DRPWO

128 dB SPL

90 dB SPL

PSE63-DRW

125 dB SPL

90 dB SPL

PSE63-DRWO

124 dB SPL

90 dB SPL

PSE63-DRSW

123 dB SPL

90 dB SPL

PSE63-DRSWO

123 dB SPL

90 dB SPL

PSE62-DRP

128 dB SPL

90 dB SPL

PSE62-DRPO

128 dB SPL

90 dB SPL

PSE62-DR

125 dB SPL

90 dB SPL

PSE62-DRO

124 dB SPL

90 dB SPL

PSE62-DRS

123 dB SPL

90 dB SPL

PSE62-DRSO

123 dB SPL

 90 dB SPL

Summary of Contents for MRIE

Page 1: ...Instructions for use Digital Receiver In the Ear RIE hearing Instruments...

Page 2: ...ns However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determine...

Page 3: ...ollowing variants TRU1763DW TRU1763DPW TRU963DW TRU963DPW TRU663DW TRU663DPW TRU363DW TRU363DPW Digital Receiver In the Ear RIE wireless hearing Instruments models type SY312e are available in followi...

Page 4: ...model 48 Warning to hearing care professional i A hearing care professional should advise a prospective user to consult promptly with a licensed physi cian preferably an ear specialist before setting...

Page 5: ...Receiver Tulip Dome 2c Receiver Power Dome 2d RIE mold 3 Sports lock 4 Battery compartment 5 Receiver 6 Push button 64DW 7 Multi function button 8 Model and serial number 9 Left right indicator 63DW...

Page 6: ...of life The hearing instru ment will reduce amplification and emit a melody if battery power gets too low This signal will recur every five minutes until the hearing instrument automatically switches...

Page 7: ...ace batteries in your mouth Consult a physician immediately if a battery has been swallowed as they can be harmful to your health DO NOT burn the batteries as they could explode DO NOT attempt to rech...

Page 8: ...he receiver tube sticking out when you look directly into a mirror 5 If the device whistles the most likely reason is that the receiver dome is not placed correctly in the ear canal Other reasons can...

Page 9: ...New setting Short press up Increases volume Short press down Decreases volume Long press up 3 seconds Changes programs Long press down 3 seconds Activates streaming Program and Multi Function buttons...

Page 10: ...l give one single beep if set in program 1 two beeps if set in program 2 three beeps if set in program 3 four beeps if set in program 4 When you close the battery door and switch the instrument on it...

Page 11: ...the telephone vertically in a position similar to when making a telephone call 3 Place the magnets just below the telephone receiver Make sure not to cover the microphone openings If necessary move t...

Page 12: ...und quality through induction loop is often better because noises from the environment are not transmitted Switch your instrument to the telecoil program Choose a good spot Reception is not clear in a...

Page 13: ...to the nature of your particular cellular phone or of your wireless telephony service provider If you find it difficult to obtain a good result while using your cellular phone your hearing care profes...

Page 14: ...manually it is possible to re enable wireless operation by opening and closing the battery door 10 seconds after this operation is completed wireless operation will begin again Daily maintenance Keep...

Page 15: ...attempt to modify theshape of the receiver tube yourself The receiver tube and the receiver dome RIE mold should be cleaned regularly Cleaning the receiver tube and the receiver domes The receiver tub...

Page 16: ...ieve suffering from tinnitus Tinnitus Breaker Pro can generate sounds adjusted to the specific therapeutic needs and your personal preference as determined by your doctor audiologist or hearing care p...

Page 17: ...al of the device CAUTION Tinnitus Sound Generator i The maximum output of the Tinnitus Breaker Pro feature falls into the range that can cause hearing loss according to OSHA regulations The user shoul...

Page 18: ...2 4 GHz 2 48 GHz 63DW and 64DW models This device includes a RF transmitter that operates in the range of 2 4 GHz 2 48 GHz 63DW and 64DW models General warnings i Hearing instruments can be dangerous...

Page 19: ...areful with sounds from heavy traffic at this stage of getting used to your instrument Sometimes it sounds very loud Try not to get frightened 3 Have a conversation with a single person Use your instr...

Page 20: ...strument meets strict international regulations Therefore it should be possible to use a GSM telephone in most cases However in some circumstances disturbance might be audible through your hearing ins...

Page 21: ...or if you have been in structed change receiver dome or and wax guard filter Not loud enough Receiver dome not inserted properly Reinsert carefully Blocked wax guard filter Consult your hearing profe...

Page 22: ...t settings not optimum Consult your hearing care professional Not clear distorted Weak battery Replace battery Poorly fitting receiver tube Consult your hearing care professional Hearing instrument da...

Page 23: ...modulated in amplitude with an attenuation depth of up to 14dB Hearing instrument maximum output and Tinnitus Breaker Pro sound generator maximum overall output IEC 118 0 OES Model Hearing instrument...

Page 24: ...rom new or serviceable used parts or repaired using new or refurbished replacement parts The warranty period of hearing instruments is designated on your warranty card which is provided by your hearin...

Page 25: ...312 Beltone True Type Battery size Receiver tube type and length size TRU963DW RIE 312 TRU963DWO RIE 312 TRU963DPW RIE 312 TRU963DPWO RIE 312 TRU663DW RIE 312 TRU663DWO RIE 312 TRU663DPW RIE 312 TRU6...

Page 26: ...E 312 PSE963 DRW RIE 312 PSE963 DRWO RIE 312 PSE963 DRSW RIE 312 PSE963 DRSWO RIE 312 PSE664 DRPW RIE 312 Beltone True Type Battery size Receiver tube type and length size PSE664 DRPWO RIE 312 PSE664...

Page 27: ...PSE1762 DR RIE 10A PSE1762 DRO RIE 10A PSE1762 DRS RIE 10A PSE1762 DRSO RIE 10A PSE962 DRP RIE 10A PSE962 DRPO RIE 10A PSE962 DR RIE 10A PSE962 DRO RIE 10A PSE962 DRS RIE 10A PSE962 DRSO RIE 10A Belto...

Page 28: ...ous injuries CAUTION indicates a situation that could lead to minor and moderate injuries Equipment includes RF transmitter Product is a Type B applied part i Advice and tips on how to handle your hea...

Page 29: ...2750 Ballerup Denmark Tel 45 45 75 11 11 Fax 45 45 75 11 19 www beltone hearing com CVR no 55082715 Any issues relating to the EU Medical Device Directive 93 42 EEC or Council Directive 1999 5 EEC on...

Reviews: