background image

11 

 

shift mode. 

2

Press "Scan/M" button can change the unit. 

             

 

3

press "ON/OFF" to finish unit shift. 

4.After completing the measurement , please pack the protective cover and store it in 

required environment. 

Cleaning instructions:   

1

 

Sensitive head is the most  important part of  the device, and the front mirror is 
fragile.  The  sensitive  dead  can  be  cleaned  with  cotton  swab  or  soft  cloth  with 
alcohol / warm water 

2

 

Clean LCD and cover with clean soft cloth, do not  use solvent, do not dip  into 
water or other liquid. 

3

Please cover protective cover if don't use, avoid dust pollution and direct 

sunlight .storage the thermometer environmental conditions should maintain relative 
stability, had better be in 16-35, humidity is not more than 90% RH environment, so it is 
easy to use at any time 

  Description  of  maintenance  and  who  should  do  it:  Please  hande  it  over  to  a 

professional personnel to carry on maintaining 

  Storage instructions: 

Please pack good protective sleeve in the collection bag if don

’t use the thermometer.If it is 

not installed protective sleeve state custody, it may cause a malfunction 

Please make sure the thermometer , collection bag and protective sleeve out of the reach 
of the baby, otherwise may cause failure 

Please don

’t    put the thermometer into the collection bag storage when it’s wet.Or it may 

cause a failure 

. please do not place the device in too high/low temperature and humility environment, to 
avoid sunshine, keep away from electric shock and dusty environment. 

Summary of Contents for ETE-68B4

Page 1: ...1 ETE 68B4 Infra red Ear Thermometer...

Page 2: ...nology it can get stable and accurate measurement result every time This product will self test and display the current room temperature when starting up to ensure the accuracy of the measurement This...

Page 3: ...oduct and or property damage Type BF Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary This item is compliant with Medical...

Page 4: ...safely and see that it is in proper working condition before being used The manufacturer does not require such preventive inspections by other persons The ear thermometer is used only for testing it c...

Page 5: ...ent accurancy and avoid cross infection Please don t add any protective sleeve to the sensor or the measurement result will be incorrect please make sure the device appearance is not damaged and the s...

Page 6: ...s cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of th...

Page 7: ...n This product pass clinical verification the clinical maximum allowable error is 0 3 bluetooth function Bluetooth 4 0 transmission android and apple 4 0 Body temperature A person s normal temperature...

Page 8: ...e protection cover on the head CAUTION Protective cover is used only when storing you must take down protective cover when measuring 2 Press the ON OFF button and the device start self calibration all...

Page 9: ...of ear wax in the ear The ear temperature may be high if you lie on the side and one ear is compressed so after going to bed please do not measure in the ear which is compressed on the side If you wa...

Page 10: ...u clearly see the ear canal then deep into as much as possible When measuring the ear temperature for sleeping baby Please make sure the ear up let face in a horizontal position with one hand holds th...

Page 11: ...s should maintain relative stability had better be in 16 35 humidity is not more than 90 RH environment so it is easy to use at any time Description of maintenance and who should do it Please hande it...

Page 12: ...out the batteries to avoid battery leaking if the unit is not used for over six months Instructions on how to safely dispose of the device Batteries should be disposed of separately from household was...

Page 13: ...PG equipment 5 Mode of operation continuous operation Additional Information non toxic No Stimulation No sensitization adverse reaction for user during test Disease and self care information The devic...

Page 14: ...ect operating problems caused by unprofessional repair supply the purchase prove when require warranty the repair will be charged if not in warranty period or range we keep the final explanation right...

Reviews: